Lei Kong

Lei Kong

Auto-generated profile, based on publicly available information

Lei Kong

National Key Laboratory of Optical Field Manipulation Science and Technology, the Key Laboratory of Optical Engineering, Institute of Optics and Electronics, Chinese Academy of Sciences, Chengdu, China

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 February 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
LKLei Kong
Lei Kong
YMYao Mao
Yao Mao
TZTing Zhang
Ting Zhang
XCXinglong Chen
Xinglong Chen
ZWZheng Wang
Zheng Wang
XWXueqing Wang
Xueqing Wang
This article proposes a data-driven online diagnosis method for detecting common electrical faults and current sensor faults (CSFs) in dual three-phase permanent-magnet synchronous motor (DTP-PMSM) drives. The proposed diagnosis method fulfills feature extraction by obtaining the average values of phase currents in the positive and negative half-cycles of fault features to reduce dimensionality. By designing a one-vote veto classification rule, the proposed diagnosis method can accurately distinguish 24 fault modes and effectively prevent misdiagnosis. The classification model consists of only 24 decision functions, making it easy to implement on the mainstream industrial microcontrollers. The experiments are carried out to verify the validity of the proposed method.

27 May 2025 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
YZYun Zhang
Yun Zhang
XWXueqing Wang
Xueqing Wang
LKLei Kong
Lei Kong
LLLinlin Lu
Linlin Lu
ZWZheng Wang
Zheng Wang
YMYao Mao
Yao Mao
Conventional sensorless control can hardly estimate the rotor position of faulty drives, which will cause the breakdown of the sensorless permanent-magnet synchronous motor (PMSM) drives in short time. In this article, a fault-tolerant (FT) control scheme is proposed for common electrical faults and sensor faults in the sensorless PMSM drive without using any auxiliary facilities. In the proposed FT control scheme, by simply updating the voltage inputs in the nonlinear flux observer, the rotor position is accurately estimated in open-phase fault (OPF) and open-switch fault (OSF). With the aid of the estimated rotor position, the current references are optimized by considering the tracking error and torque ripple for OSF and OPF. Besides, a Luenberger observer based on stator voltages model is established to estimate the faulty phase current in current sensor fault. The FT control for voltage sensor fault is realized by compensating the measured dc-link voltage. Experimental verification is conducted to prove the validity of the proposed FT control scheme.

18 December 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YZYun Zhang
Yun Zhang
XWXueqing Wang
Xueqing Wang
JPJinjin Peng
Jinjin Peng
LKLei Kong
Lei Kong
ZWZheng Wang
Zheng Wang
YMYao Mao
Yao Mao
In this paper, fault diagnosis and adaptive fault-tolerant control (FTC) are proposed for the interturn short-circuit (ITSC) fault in permanent magnet synchronous motor (PMSM) drives. The fault diagnosis is realized by extracting the speed fluctuation caused by the ITSC fault. The dq-axis current injection based adaptive FTC scheme is applied to gradually reduce the speed fluctuation and torque ripple caused by the ITSC fault. The proposed method can achieve excellent fault diagnosis and fault-tolerant (FT) performances without using any machine model or auxiliary circuit. The experiments are conducted to verify the effectiveness of the proposed fault diagnosis and adaptive FTC.