I. V. Pavliuk

I. V. Pavliuk

Auto-generated profile, based on publicly available information

I. V. Pavliuk

Zaporizhzhia Scientific-Research Forensic Expert Centre of the Ministry of Internal Affairs of Ukraine

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 October 2023 in Pharmacia
Verified
Journal Article
Open access
PDF file
Olexiy GoncharovOlexiy Goncharov
Olexiy Goncharov
IBIgor Belenichev
Igor Belenichev
AAAndrii Abramov
Andrii Abramov
OPOlena Popazova
Olena Popazova
LKLudmila Kucherenko
Ludmila Kucherenko
IPIvan Pavliuk
Ivan Pavliuk
In the complex treatment of chronic heart failure (CHF) β-adrenoblockers (carvedilol, nebivolol, bisoprolol, metoprolol) are used, which due to their pharmacological properties increase the survival rate of patients, improve cardio- and haemodynamic parameters, metabolism. However, modern realities in medicine require creation of new more effective and safe β-adrenoblockers. In this regard, the potential drug Hypertirl is of interest. The aim was to evaluate the cardioprotective effect of 1-(b-phenylethyl)-4-amino-1,2,4-triazolium bromide (Hypertril) on cardiac electrical activity and autonomic regulation of heart rhythm in a model of CHF in comparison with β-adrenoblockers of different generations (Nebivolol, Carvedilol, Bisoprolol, Metoprolol). Materials and methods: Chronic heart failure was induced by 14-day administration of doxorubicin in a cumulative dose of 15 mg/kg to white mongrel rats weighing 190–220g (total 85). The investigated drugs were administered after doxorubicin course for 30 days: Hypertril at an experimentally substantiated dose of 3.5 mg/kg, Metoprolol succinate 15 mg/kg, Nebivolol 10 mg/kg, Carvedilol 50 mg/kg, Bisoprolol 10 mg/kg. At the end of drug administration under thiopental anaesthesia (40 mg/kg), electrocardiogram (ECG) and autonomic regulation of heart rhythm (ARHR) were analysed using a computer analyser CardioCom-2000plus (KAI-Medica, Ukraine). The results of the study were calculated using a standard statistical package “STATISTICA for Windows 6.0” (StatSoftInc., №AXXR712D833214FAN5), “SPSS 16.0” and “Microsoft Office Excell 2003”. Results and discussion: Hypertril administration resulted in a negative chronotropic effect, normalisation of atrial (P) and ventricular (R) spike amplitude, ST segment inversion below isoline, increased amplitude of ventricular myocardial repolarisation T. Myocardial repolarisation spike were observed, as well as normalised the duration of atrial (P) and ventricular depolarisation phase (QRS complex) to the intact value and restored the duration of electrical diastole (TR interval). Hypertril reduced systolic and diastolic myocardial dysfunction in animals with CHF. Hypertril restored autonomic mechanisms of heart rhythm regulation and balanced activity of sympathetic and parasympathetic parts of autonomic nervous system in the control of cardiac function. Conclusion: The obtained results demonstrated the undoubted advantage of the new original molecule (Hypertril) over basic β-adrenoblockers (Metoprolol, Nebivolol, Carvedilol and Bisoprolol) and experimentally justify further in-depth study to create on its basis a drug for the treatment of CHF.

3 November 2023 in Current issues in pharmacy and medicine: science and practice
Verified
Journal Article
Open access
PDF file
LKLudmila Kucherenko
Ludmila Kucherenko
RAR. R. Akopian
R. R. Akopian
OPO. O. Portna
O. O. Portna
OKO. V. Khromylova
O. V. Khromylova
IPI. V. Pavliuk
I. V. Pavliuk
One of the most common eye diseases is a burn injury. Hence, one of the pressing challenges in the field of pharmacy today is the development of new ophthalmic medications, specifically eye drops. Researchers from the Department of Pharmaceutical, Organic, and Bioorganic Chemistry at Zaporizhzhia State Medical and Pharmaceutical University, led by Professor I. A. Mazur, have successfully synthesized a novel compound. This compound is a derivative of 1,2,4-triazole, specifically (S)-2,6-diaminohexanoic acid 3-methyl-1,2,4-triazolyl-5-thioacetate. Notably, this compound demonstrates anti-inflammatory, wound-healing, and reparative activities. The aim of the work is to develop a method of quantitative determination of the active substance in Angiolin eye drops by the method of high-performance liquid chromatography. Materials and methods. The research employed a liquid chromatograph equipped with a UV detector. A column Hypersil ODS C-18 measuring 250 by 4.6 millimeters with a particle size of 5 microns was used. Results. It was determined that the angiolin content in the 1 % eye drops in series 1 falls within the range of 0.985 to 1.010 grams. This indicates that, in terms of the active substance content, the studied series complies with the requirements of the State Pharmacopoeia of Ukraine. Conclusions. As a result of the conducted research, a method for quantitatively determining the active substance in Angiolin eye drops using high-performance liquid chromatography was developed.

10 March 2025 in Current issues in pharmacy and medicine: science and practice
Verified
Journal Article
Open access
LKLudmila Kucherenko
Ludmila Kucherenko
IPI. V. Pavliuk
I. V. Pavliuk
OKO. V. Khromylova
O. V. Khromylova
Molecular genetics is one of the key tools of modern medicine. With its help, scientists can study the structure and function of DNA, decode genetic codes, and develop new treatments. In the conditions of the modern world, where global crises, such as the war in Ukraine, occur more and more often, the role of molecular genetics goes far beyond standard medical tasks and becomes critically important for solving social, legal and humanitarian problems. Thus, molecular technologies have become an important tool both in the public health maintenance and in the human rights protection. Aim. Study and optimization of methods of molecular genetic identification of a person using DNA analysis in forensic practice. Materials and methods. The study is aimed at evaluating the effectiveness and accuracy of DNA analysis for solving identification tasks, as well as its application in the conditions of complex biological samples, which is important for ensuring the reliability of DNA expertise results in the context of forensics. At the first stage, a cytological examination is performed to identify cells with nuclei, after which DNA extraction is performed using proteinase treatment, phenol-chloroform purification, or the “Chelex” ion exchange resin method. The “Applied Biosystems” 7300 RealTime PCR Systems device is used to assess the quantity and quality of the isolated DNA, which allows to establish the state of the DNA for further analysis by the polymerase chain reaction (PCR) method. With the help of this method, which allows amplification of even minimal fragments of DNA, it is possible to obtain millions of copies of DNA, which enables its further study, even in the presence of trace amounts of biological traces. The obtained data are analyzed using the “Applied Biosystems” 3500 genetic analyzer, which has 8 columns and allows the simultaneous analysis of 8 objects and the four-channel “SeqStudio” genetic analyzer. This method helps to detail the length of DNA fragments and distinguish them by fluorescent labeling, which is used to build a DNA profile and establish kinship or identity. Results. The results of the study confirm that the use of molecular methods allows achieving high levels of accuracy, reproducibility and reliability of data. This is especially important for complex cases where other methods cannot give the desired result. As a result, molecular technologies of DNA analysis have proven themselves as an effective method that allows not only to identify a person, but also to restore the chronology of events based on micro-traces of traces of biological origin, which significantly increases the accuracy and reliability of examinations, and helps in solving crimes. Conclusions. The introduction of molecular technology into expert practice allows to perform the analysis of extremely small amounts of nuclear and mitochondrial DNA and thus to achieve the maximum effectiveness of researching the most complex biological objects to date: hair that has fallen out (one of the most frequently recovered objects from crime scenes); bone remains (including exhumed ones); mummified and dried tissues; cells of the epidermis. In the world, forensic DNA analysis is recognized as one of the most promising areas of development of forensic examinations, and its results are currently one of the most reliable pieces of evidence. This proves the relevance of research in the field of molecular biology and genetics, which are aimed at improving the methods of DNA analysis. The relevance of research is also due to the need to increase the accuracy and reliability of the obtained data, which is especially important when working with minimal biological samples or severely damaged materials.

30 December 2025 in ScienceRise: Pharmaceutical Science
Verified
Journal Article
Open access
PDF file
LKLudmila Kucherenko
Ludmila Kucherenko
DODmytro Okolzin
Dmytro Okolzin
BBBogdan Burlaka
Bogdan Burlaka
SBSerhii Borsuk
Serhii Borsuk
OBOleksii Bihdan
Oleksii Bihdan
IPIvan Pavliuk
Ivan Pavliuk
In modern conditions, in particular, against the background of an increase in the frequency of traumatic injuries to the organs of vision because of hostilities and the influence of professional factors, the development of new ophthalmic dosage forms is of particular relevance. Combined drugs containing several active pharmaceutical ingredients, in particular diclofenac sodium and para-aminobenzoic acid, are considered promising solutions for the treatment of infectious and inflammatory eye lesions. At the same time, the effectiveness and safety of such combinations directly depend on their physicochemical compatibility, which determines the stability of the finished dosage form. The aim of the study is to investigate the thermal stability and possible physicochemical interactions between diclofenac sodium and para-aminobenzoic acid by derivatographic analysis of individual substances and their mixture in a 1:1 ratio. Materials and methods. The objects of the study were the pharmaceutical substances diclofenac sodium, para-aminobenzoic acid and a model mixture of the specified active pharmaceutical ingredients. Thermogravimetric analysis was carried out on a Shimadzu DTG-60 device in thermogravimetric analysis and differential thermal analysis modes in the temperature range of 17–250 °C with a heating rate of 10 °C/min in an air atmosphere. Results. In the process of thermogravimetric research, it was established that diclofenac sodium is characterized by high thermal stability. Para-aminobenzoic acid showed three stages of thermal destruction, but analysis of the mixture in a 1:1 ratio did not reveal the appearance of new thermal effects or shifts in the degradation profiles. Conclusions. The results of thermogravimetric analysis indicate the compatibility of diclofenac sodium and para-aminobenzoic acid in terms of thermal characteristics, which confirms the prospects of their simultaneous use

28 February 2022 in ScienceRise: Pharmaceutical Science
Verified
Journal Article
Open access
PDF file
KMKateryna Miedviedieva
Kateryna Miedviedieva
SVSvitlana Vasyuk
Svitlana Vasyuk
AKAlla Korzhova
Alla Korzhova
IPIvan Pavljuk
Ivan Pavljuk
Epilepsy is considered one of the most common chronic neurological diseases among humans. Lamotrigine is an effective new-generation anticonvulsant, which is widely introduced to the pharmaceutical market by various drug manufacturers. That is why the urgent aim for pharmaceutical analysis is developing of high precision, valid, accessible and quantitative methods for lamotrigine in pharmaceuticals. The aim of the work is to study the optimal conditions for the reaction between lamotrigine and diazole red 2J, to define the coefficients of stoichiometric relationships in the “pharmaceutical substance – reagent” system and to develop a valid, sensitive and easy-to-follow technique for the quantitative determination of lamotrigine in pharmaceutical forms. Material and methods. As reagent and solvent, diazole red 2J of AR grade and acetone of AR grade were used. Analytical equipment: Specord 200 spectrophotometer, ABT-120-5DM electronic scales, Elmasonic E 60H ultrasonic bath and measuring glassware of A class. Results. A new spectrophotometric method for the quantitative determination of lamotrigine in four pharmaceutical formulations based on interaction with diazole red 2J in acetone medium has been developed. The proposed method is valid according to such validation characteristics as linearity, precision, intra-laboratory precision, accuracy, application range and robustness. The subordination to Behr's law is in the range of concentrations of 2.20–3.36 mg/100 ml. The LOD and LOQ values based on the values of the calibration line were 0.00450 % and 0.0138 % respectively. It was found that the studied coloured solutions are stable for at least 60 min and fluctuations in the amount of added red diazole 2J solution within ±10 % do not significantly affect the value of optical density. The coefficients of stoichiometric ratios between the components of the “lamotrigine – diazole red 2J” reaction mixture were defined by three methods and are 1:1. The predicted complete uncertainty of the results of analysis for quantitative determination of lamotrigine in the pharmaceutical form (2.2 %) does not exceed the maximum allowable uncertainty for the technique (3.2 %) and meets the SPhU requirements. Conclusions. According to the experimental data, the technique can be correctly reproduced and it is suitable for using in laboratories of the State Inspection for Quality Control of Medicines and QCD of the chemicopharmaceutical enterprises

24 November 2025 in Current issues in pharmacy and medicine: science and practice
Verified
Journal Article
Open access
LKLudmila Kucherenko
Ludmila Kucherenko
DZD. V. Zubryk
D. V. Zubryk
IPI. V. Pavliuk
I. V. Pavliuk
HNH. R. Nimenko
H. R. Nimenko
In modern forensic practice, molecular genetic studies play an extremely important role, especially in wartime. DNA identification allows you to identify a person by traces of biological origin, which has become critically important for the identification of the dead and missing. The effectiveness of such studies largely depends on the choice of the optimal method of DNA extraction, which ensures the reliability and speed of results. In this regard, the choice of the most reliable, sensitive and resource-efficient method of DNA extraction becomes not only a technical but also a strategic task that directly affects the success of investigations and the reduction of the number of missing persons, which is extremely important in the humanitarian dimension of modern war. Aim. Comparative analysis of two commercial kits for manual DNA extraction — PrepFiler™ Forensic DNA Extraction Kit (Applied Biosystems) and NucleoSpin® DNA Forensic (Macherey-Nagel) — to determine the feasibility of their use for different types of biological samples and traces and categories of expert workload. Materials and methods. The study was conducted on the basis of the analysis of samples of trace biological material, in particular blood stains, saliva, tissue fragments and traces from the surfaces of objects. Two sets of reagents were used for DNA extraction: PrepFiler™ Forensic DNA Extraction Kit (Thermo Fisher Scientific) and NucleoSpin® DNA Forensic (Macherey-Nagel), 100 reactions each. DNA extraction was carried out according to the protocols provided by the manufacturers. The quality and quantity of the isolated DNA were determined by real-time polymerase chain reaction using the Applied Biosystems 7300 Real-Time PCR System. Further genotyping was performed by capillary electrophoresis on the Applied Biosystems 3500 Genetic Analyzer. Results. Comparative analysis showed that NucleoSpin® DNA Forensic is optimal for fast and convenient DNA isolation from simple reference samples such as saliva or blood, where no significant degradation or inhibitors are observed. It provides sufficient DNA concentration in a short time, however, in cases of working with complex or degraded samples (especially bone remains), partial STR profiles were more often observed. In contrast, PrepFiler™ and, in particular, PrepFiler™ BTA demonstrated better performance under such difficult conditions, providing complete profiles even in the presence of inhibitors or prolonged degradation. This makes it a reasonable choice for forensic cases with problematic samples, despite the higher cost. Conclusions. Molecular genetic research is a key tool in modern forensic practice, in particular for identifying a person from biological samples. The use of DNA identification methods based on polymerase chain reaction (PCR) ensures high accuracy and reliability of forensic examinations in criminal and civil cases, and also plays an important role in the identification of the deceased and missing, especially in wartime conditions. A comparative analysis of two commercial kits for manual DNA extraction — PrepFiler™ Forensic DNA Extraction Kit and NucleoSpin® DNA Forensic — showed that both kits have their advantages and can be effectively used depending on the type of biological material and the conditions of the examination. The choice of the optimal DNA extraction method significantly affects the quality and quantity of the obtained genetic material, which, in turn, determines the reliability of DNA profiling and the speed of the expert laboratory.