20 November 2006 in Clinical Research in Cardiology
27 September 2008 in Journal of Interventional Cardiac Electrophysiology
10 January 2012 in EP Europace
Magnetic resonance imaging (MRI) is the imaging modality of choice in many clinical situations, and its use is likely to grow due to expanding indications and an ageing population. Many patients with implantable devices are denied MRI except in cases of urgent need, and when scans must be performed they are complicated by the need for burdensome and costly personnel and monitoring requirements that have the net effect of restricting access to scans. Several small studies, enrolling a total of 344 patients, suggest that some patients with conventional systems may undergo MR examinations without clinically overt adverse events. However, a number of potential interactions exist between implantable cardiac devices and the static and gradient magnetic fields and modulated radio frequency (RF) fields generated during MR scans; nearly all studies have reported pacing capture threshold changes, troponin elevations, ectopy, unpredictable reed switch behaviour, and other ‘subclinical’ issues with pacemakers and implantable cardioverter-defibrillators (ICDs) in patients who have undergone MRI. Attention has turned to devices that are specifically designed to be safe in the MRI environment. A clinical study of one such device documented its ability to be exposed to MRI in a 1.5 T scanner without adverse impact on patient outcomes or pacemaker system function. Such new technologies may enable scanning of pacemaker and ICD patients with reduced concerns regarding the short- and long-term effects of MRI. As importantly, these devices may increase the number of centres that are able to safely perform MRI and, thus, expand access to scans for patients with these devices.
2 June 2014 in BMC Cardiovascular Disorders
It is uncertain whether gender differences in outcome after primary percutaneous coronary intervention (PCI) are only attributable to different baseline characteristics or additional factors. Databases of two German myocardial infarction network registries were combined with a total of 1104 consecutive patients admitted with acute ST-elevation myocardial infarction (STEMI) and treated according to standardized protocols. Approximately 25% of patients were females. Mean age (69 vs 61 years), incidence of diabetes (28% vs 20%), hypertension (68 vs 58%) and renal insufficiency (26% vs 19%) was significantly higher compared to males. Mean prehospital delay was numerically longer in females (227 vs 209 min) as was in hospital delay (35 vs 30 min). PCI was finally performed in 92% of females and 95% of males with comparable procedural success (95% vs 97%). Use of drug eluting stents (55% vs 68%) and application of GP 2b 3a blockers (75% vs 89%) was significantly less frequent in women. At discharge, prescription of beta blockers and lipid lowering drugs was also significantly lower in females (84% vs 90% and 71% vs 84%). Unadjusted in-hospital mortality was significantly higher in females (10% vs 5%) without attenuation after 12 months. Adjusted mortality however did not differ significantly between genders. Higher unadjusted mortality in females after primary PCI was accompanied by significant differences in baseline characteristics, interventional approach and secondary prophylaxis in spite of the same standard of care. Lower guideline adherence seems to be less gender specific but rather a manifestation of the risk-treatment paradox.
13 October 2011 in Journal of Interventional Cardiac Electrophysiology
Due of its superior soft tissue imaging capabilities, magnetic resonance imaging (MRI) has become the imaging modality of choice in many clinical situations, as illustrated by the tremendous growth in the number of MRIs performed over the past 2 decades. In parallel, the number of patients who require pacemakers or implantable cardiac defibrillators is increasing as indications for these devices broaden and the population ages. Taken together, these phenomena present an important clinical issue, as MR scans are generally contraindicated—except in urgent situations—in patients who have implanted cardiovascular devices. Potentially deleterious interactions between the magnetic fields and radio frequency (RF) energy produced by MR equipment and implantable devices have been identified, including inhibition of pacing, asynchronous/high-rate pacing, lead tip heating, and loss of capture. New devices that incorporate technologies to improve MR safety in patients with pacemakers have recently received approval in Europe and are under evaluation in the United States. Initial data from these devices suggest that these devices are safe in the MRI environment.
1 March 2016 in Coronary Artery Disease
The PERfECT Stent Study compared paclitaxel-coated balloon (PCB) angioplasty plus bare-metal stent (BMS) implantation with BMS alone in de-novo lesions in native coronary artery disease. Angiographic follow-up after 6 months showed the superiority of the additional PCB. We evaluated a potential late catch-up phenomenon with the use of PCB. In the prospective, multicenter, single-blind, randomized PERfECT Stent trial, 120 patients were assigned to either PCB angioplasty plus BMS implantation or BMS alone. For BMS, the endothelial progenitor cell capturing stent was used. Dual antiplatelet therapy was recommended for 3 months. The clinical endpoint for 5-year follow-up was a composite of cardiac death, myocardial infarction attributed to the target vessel, or target lesion revascularization. The follow-up rate after 5 years was 97%. Baseline and procedural characteristics did not differ. At the 5-year follow-up, clinically driven target lesion revascularization was 23.2% in the BMS group versus 15% with PCB plus BMS (P=0.26). The clinical endpoint (major adverse cardiac event) was 30.4% with BMS and with 23.5% lower with PCB plus BMS. No definite or probable stent thrombosis was found in either group with a dual antiplatelet therapy for 3 months for the total period. PCB angioplasty plus BMS was superior to BMS alone for the treatment of de-novo lesions. The combined clinical endpoint was lower with PCB plus BMS at 6 months and remained lower after 5 years. There was no late catch-up phenomenon (http://www.clinicaltrials.gov; NCT 00732953).