Tamara Sobers

Tamara Sobers

Auto-generated profile, based on publicly available information

Tamara Sobers

Univ. of Massachusetts Amherst (United States)

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 June 2017 in IEEE Transactions on Wireless Communications
Verified
Journal Article
Open access
TSTamara V. Sobers
Tamara V. Sobers
BBBoulat A. Bash
Boulat A. Bash
SGSaikat Guha
Saikat Guha
DTDon Towsley
Don Towsley
DGDennis Goeckel
Dennis Goeckel
Recent work has established that when transmitter Alice wishes to communicate reliably to recipient Bob without detection by warden Willie, with additive white Gaussian noise (AWGN) channels between all parties, communication is limited to O(√n) bits in n channel uses. However, this assumes that Willie has an accurate statistical characterization of the channel. When Willie has uncertainty about such and his receiver is limited to a threshold test on the received power, Alice can transmit covertly with a power that does not decrease with n, thus conveying O(n) bits covertly and reliably in n uses of an AWGN channel. Here, we consider covert communication of O(n) bits in n channel uses while generalizing the environment and removing any restrictions on Willie's receiver. We assume that an uninformed “jammer” is present to help Alice, and we consider AWGN and block fading channels. In some scenarios, Willie's optimal detector is a threshold test on the received power. When the channel between the jammer and Willie has multiple fading blocks per codeword, a threshold test on the received power is not optimal. However, we establish that Alice can remain covert with a transmit power that does not decrease with n even when Willie employs an optimal detector.

1 November 2015
Verified
Conference Paper
Closed access
TSTamara V. Sobers
Tamara V. Sobers
BBBoulat A. Bash
Boulat A. Bash
DGDennis Goeckel
Dennis Goeckel
SGSaikat Guha
Saikat Guha
DTDon Towsley
Don Towsley
Recent work has established that when transmitter Alice wishes to communicate reliably to recipient Bob without detection by warden Willie, with additive white Gaussian noise (AWGN) channels between all parties, communication is limited to O(√n) bits in n channel uses. However, this result is predicated on Willie having an accurate statistical characterization of the background noise. When Willie has uncertainty about his noise characteristics and his receiver is limited to a power detector, O(n) bits can be covertly delivered. Here, we establish covert communication of O(n) bits in n channel uses while: (i) generalizing the environment; and (ii) removing any restrictions on Willie's receiver. We consider the case where an additional node, called the "jammer", is present to help Alice and Bob communicate covertly. This jammer is termed "uninformed", as it does not know the content or timing of Alice's transmission. We consider both AWGN channels and a scenario with a block faded jammer with a single fade per codeword. In these scenarios, we are able to establish the optimality of the power detector for Willie, from which the achievability of reliable and covert communication at a positive rate follows.

23 February 2012
Verified
Conference Paper
Closed access
PDF file
PKPatrick A Kelly
Patrick A Kelly
TSTamara Sobers
Tamara Sobers
BPBenjamin St Peter
Benjamin St Peter
Paul SiqueiraPaul Siqueira
Paul Siqueira
GCGeoffrey Capraro
Geoffrey Capraro
Because of its ability to measure the temperature-dependent power of electromagnetic radiation emitted from tissue down to several centimeters beneath the skin, microwave radiometry has long been of interest as a means for identifying the internal tissue temperature anomalies that arise from abnormalities in physiological parameters such as metabolic and blood perfusion rates. However, the inherent lack of specificity and resolution in microwave radiometer measurements has limited the clinical usefulness of the technique. The idea underlying this work is to make use of information (assumed to be available from some other modality) about the tissue configuration in the volume of interest to study and improve the accuracy of anomaly detection and estimation from radiometric data. In particular, knowledge of the specific anatomy and the properties of the overall measurement system enable determination of the signatures of localized physiological abnormalities in the radiometry data. These signatures are used to investigate the accuracy with which the location of an anomaly can be determined from radiometric measurements. Algorithms based on matches to entries in a signature dictionary are developed for anomaly detection and estimation. The accuracy of anomaly identification is improved when the coupling of power from the body to the sensor is optimized. We describe the design of a radiometer waveguide having dielectric properties appropriate for biomedical applications.

3 March 2011
Verified
Conference Paper
Closed access
PDF file
PKPatrick Kelly
Patrick Kelly
TSTamara Sobers
Tamara Sobers
BPBenjamin St. Peter
Benjamin St. Peter
PSPaul Siqueira
Paul Siqueira
GCGeoffrey Capraro
Geoffrey Capraro
Many medically significant conditions (e.g., ischemia, carcinoma and inflammation) involve localized anomalies in physiological parameters such as the metabolic and blood perfusion rates. These in turn lead to deviations from normal tissue temperature patterns. Microwave radiometry is a passive system for sensing the radiation that objects emit naturally in the microwave frequency band. Since the emitted power depends on temperature, and since radiation at low microwave frequencies can propagate through several centimeters of tissue, microwave radiometry has the potential to provide valuable information about subcutaneous anomalies. The radiometric temperature measurement for a tissue region can be modeled as the inner product of the temperature pattern and a weighting function that depends on tissue properties and the radiometer's antenna. In the absence of knowledge of the weighting functions, it can be difficult to extract specific information about tissue temperature patterns (or the underlying physiological parameters) from the measurements. In this paper, we consider a scenario in which microwave radiometry works in conjunction with another imaging modality (e.g., 3D-CT or MRI) that provides detailed anatomical information. This information is used along with sensor properties in electromagnetic simulation software to generate weighting functions. It also is used in bio-heat equations to generate nominal tissue temperature patterns. We then develop a hypothesis testing framework that makes use of the weighting functions, nominal temperature patterns, and maximum likelihood estimates to detect anomalies. Simulation results are presented to illustrate the proposed detection procedures. The design and performance of an S-band (2-4 GHz) radiometer, and some of the challenges in using such a radiometer for temperature measurements deep in tissue, are also discussed.

29 March 2013
Verified
Conference Paper
Closed access
PDF file
SKSharmin Kibria
Sharmin Kibria
PKPatrick Kelly
Patrick Kelly
TSTamara Sobers
Tamara Sobers
JGJai Gupta
Jai Gupta
LGLinda Gupta
Linda Gupta
Modern medical ultrasound machines produce enormous amounts of data, as much as several gigabytes/sec in some systems. The difficulties of generating, propagating and processing such large amounts of data have motivated recent research into means for compression of the radio frequency (rf) signals received at an ultrasound system’s analog front end. Most of this work has concentrated on the digitized data available after sampling and A/D conversion. We are interested in the possibility of compression implemented directly on the received analog signals, so we focus on efficient real-time representations for the rf signals comprising a single receive aperture. We first derive an expression for the (time and space) autocorrelation function of the set of signals received in a linear aperture. This is then used to find the autocorrelation’s eigenfunctions, which form an optimal basis for minimum mean-square error (mmse) compression of the aperture signal set. Computation of the coefficients of the signal set with respect to the basis amounts to calculation of Fourier Series coefficients for the received signal at each aperture element, with frequencies scaled by aperture position, followed by linear combinations of corresponding frequency components across the aperture. The combination weights at each frequency are determined by the eigenvectors of a matrix whose entries are averaged cross-spectral coefficients of the received signal set at that frequency. The autocorrelation decomposition and signal set coefficients are also used to compute a linear mmse beamformed estimate of the aperture center line.