Steven K. Montalvo

Steven K. Montalvo

Auto-generated profile, based on publicly available information

Steven K. Montalvo

Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 April 2025 in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
Verified
Journal Article
Closed access
TMTanmay Mukherjee
Tanmay Mukherjee
SESarah Elliott
Sarah Elliott
NMNandhini Manikandan
Nandhini Manikandan
THTaylor-Jade Higgins
Taylor-Jade Higgins
YZYuncheng Zhong
Yuncheng Zhong
PAPrasanna G. Alluri
Prasanna G. Alluri

31 December 2022 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
SASean All
Sean All
BZBo Zhao
Bo Zhao
SMSteven Montalvo
Steven Montalvo
CMChristian Maxwell
Christian Maxwell
CJChristopher Johns
Christopher Johns
DKD. Nathan Kim
D. Nathan Kim
Background: Active breathing coordinator (ABC)‐assisted deep inspiration breath hold (DIBH) is an important organ sparing radiation therapy (RT) technique for left‐sided breast cancer patients. Patients with advanced breast cancer undergoing chest wall and regional nodal irradiation often require a field matching technique. While field matching has been demonstrated to be safe and effective in free breathing patients, its safety and accuracy in DIBH/ABC use has not been previously reported.Purpose: To report the accuracy, feasibility, and safety of field matching with ABC/DIBH for patients receiving breast/chest wall irradiation with nodal irradiation using a three‐field technique.Methods: From December 2012 to May 2018, breast cancer patients undergoing ABC/DIBH‐based RT at a single institution were reviewed. For each fraction, the amount of overlap/gap between the supraclavicular and the tangential field were measured and recorded. Patient characteristics, including acute and delayed skin toxicities, were analyzed.Results: A total of 202 patients utilized ABC/DIBH and 4973 fractions had gap/overlap measurements available for analysis. The average gap/overlap measured at junction was 0.28 mm ± 0.99 mm. A total of 72% of fractions had no measurable gap/overlap (0 mm), while 5.6% had an overlap and 22.7% a gap. There was no significant trend for worsening or improvement of gap/overlap measurements with increasing fraction number per patient. OSLD measurements were compared to the planned dose. The median dose 1 cm above the junction was 106% ± 7% of planned dose (range 94%–116%). One centimeter below the junction, the median dose was 114% ± 11% of planned dose (range 95%–131%). At the junction, the median dose was 106% ± 16.3% of planned dose (range 86%–131%). Acute skin toxicity was similar to historically reported values (grade 3, 5.4%, grade 4, 0%).Conclusion: ABC‐assisted DIBH is a safe and technically feasible method of delivering RT in the setting of complex matching field technique for breast and regional nodal treatments.

30 March 2023 in Breast Cancer Research and Treatment
Verified
Journal Article
Closed access
PDF file
CJChristopher Johns
Christopher Johns
SMSteven K. Montalvo
Steven K. Montalvo
MCM’kAy Cauble
M’kAy Cauble
YLYu-Lun Liu
Yu-Lun Liu
SASean All
Sean All
DKD. W. Nathan Kim
D. W. Nathan Kim

2 April 2025 in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
Verified
Journal Article
Closed access
SMSteven K. Montalvo
Steven K. Montalvo
BLBrian Lue
Brian Lue
EKEugenia Kakadiaris
Eugenia Kakadiaris
CAChul Ahn
Chul Ahn
EZElizabeth Zhang-Velten
Elizabeth Zhang-Velten
PAPrasanna G. Alluri
Prasanna G. Alluri