Jeffrey Montes

Jeffrey Montes

Auto-generated profile, based on publicly available information

Jeffrey Montes

Department of Kinesiology and Nutrition Sciences, University of Nevada, Las Vegas, Las Vegas, NV, USA

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 August 2020 in PLOS ONE
Verified
Journal Article
Open access
PDF file
James W NavaltaJames W Navalta
James W Navalta
JMJeffrey Montes
Jeffrey Montes
NBNathaniel G. Bodell
Nathaniel G. Bodell
RSRobert W. Salatto
Robert W. Salatto
JMJacob W. Manning
Jacob W. Manning
MDMark DeBeliso
Mark DeBeliso
Validation of heart rate responses in wearable technology devices is generally composed of laboratory-based protocols that are steady state in nature and as a result, high accuracy measures are returned. However, there is a need to understand device validity in applied settings that include varied intensities of exercise. The purpose was to determine concurrent heart rate validity during trail running. Twenty-one healthy participants volunteered (female n = 10, [mean (SD)]: age = 31 [11] years, height = 173.0 [7] cm, mass = 75.6 [13] kg). Participants were outfitted with wearable technology devices (Garmin Fenix 5 wristwatch, Jabra Elite Sport earbuds, Motiv ring, Scosche Rhythm+ forearm band, Suunto Spartan Sport watch with accompanying chest strap) and completed a self-paced 3.22 km trail run while concurrently wearing a criterion heart rate strap (Polar H7 heart rate monitor). The trail runs were out-and-back with the first 1.61 km in an uphill direction, and the 1.61 return being downhill in nature. Validity was determined through three methods: Mean Absolute Percent Error (MAPE), Bland-Altman Limits of Agreement (LOA), and Lin’s Concordance Coefficient (rC). Validity measures overall are as follows: Garmin Fenix 5 (MAPE = 13%, LOA = -32 to 162, rC = 0.32), Jabra Elite Sport (MAPE = 23%, LOA = -464 to 503, rC = 0.38), Motiv ring (MAPE = 16%, LOA = -52 to 96, rC = 0.29), Scosche Rhythm+ (MAPE = 6%, LOA = -114 to 120, rC = 0.79), Suunto Spartan Sport (MAPE = 2%, LOA = -62 to 61, rC = 0.96). All photoplethysmography-based (PPG) devices displayed poor heart rate agreement during variable intensity trail running. Until technological advances occur in PPG-based devices allowing for acceptable agreement, heart rate in outdoor environments should be obtained using an ECG-based chest strap that can be connected to a wristwatch or other comparable receiver.

1 January 2018 in International Journal of Exercise Science
Verified
Journal Article
Open access
PDF file
JMJeffrey Montes
Jeffrey Montes
JYJohn C. Young
John C. Young
RTRichard D. Tandy
Richard D. Tandy
James W NavaltaJames W Navalta
James W Navalta
To evaluate if the Hexoskin smart shirt (HxS) would produce valid and reliable measurements for heart rate (HR), respiratory rate (RR), minute ventilation (VE), step count (SC), and energy expenditure (EE) when compared to a Polar T-31 heart rate monitor, an Applied Electrochemistry Moxus Metabolic System, and a manual step count. A two-day walking treadmill protocol with participants walking for 3 minutes at 3 speeds (1.5mph, 2.5mph, 3.5mph, 0% grade) was performed. Forty-nine volunteers participated the first day, forty-six on the second, thirty-one were used for reliability. Values calculated for the HxS data used Pearson’s product-moment correlation (p < 0.05; r ≥ 0.70) for validity and Cronbach’s a (≥ 0.70) for reliability. HxS HR (1.5mph; p<0.01, r=0.86, a=0.86. 2.5mph; p<0.01, r=0.81, a=0.88. 3.5mph; p<0.01, r=0.85, a=0.85), HxS RR (1.5mph; p<0.01, r=0.87, a=0.93. 2.5mph; p<0.01, r=0.86, a=0.92. 3.5mph; p<0.01, r=0.71, a=0.76), HxS VE (1.5mph; p=0.66, r=0.11, a=0.70. 2.5mph; p=0.01, r=0.15, a=0.73. 3.5mph; p=0.31, r=0.08, a=0.14), HxS SC (1.5mph; p=0.90, r=-0.01, a=0.70. 2.5mph; p=0.22, r=0.13, a=0.86. 3.5mph; p<0.01, r=0.74, a=0.85), HxS EE (1.5mph; p<0.01, r=0.56, a=0.85. 2.5mph; p<0.01, r=0.50, a=0.83. 3.5mph; p<0.01, r=0.51, a=0.80). HxS HR and RR provided valid and reliable measures at all three speeds while VE, SC, and EE had a mixture of results based on speed. These results are important in the use of the Hexoskin in an accurate manner for athletes, coaches, and for the potential medical applications being advocated in the field of telemedicine procedures.

1 January 2020 in International Journal of Exercise Science
Verified
Journal Article
Open access
PDF file
JMJeffrey Montes
Jeffrey Montes
RTRichard Tandy
Richard Tandy
JYJohn Young
John Young
SLSzu-Ping Lee
Szu-Ping Lee
James W NavaltaJames W Navalta
James W Navalta
International Journal of Exercise Science 13(7): 410-426, 2020. Wearable technology devices are used by millions of people who use daily step counts to promote healthy lifestyles. However, the accuracy of many of these devices has not been determined. The purpose was to determine reliability and validity of the Samsung Gear 2, FitBit Surge, Polar A360, Garmin Vivosmart HR+, and the Leaf Health Tracker when walking and jogging in free motion and treadmill conditions. Forty volunteers completed walking and jogging free motion and treadmill protocols of 5-minute intervals. The devices were worn simultaneously in randomized configurations. The mean of two manual steps counters was used as the criterion measure. Test-retest reliability was determined via Intraclass Correlation Coefficient (ICC). Validity was determined via a combination of Pearson’s Correlation Coefficient, mean absolute percent error (MAPE: free motion ≤ 10.0%, treadmill ≤ 5.00%), and Bland-Altman analysis (device bias and limits of agreement). Significance was set at p< 0.05. The Samsung Gear 2 was deemed to be both reliable and valid for the jogging conditions, but not walking. The Fitbit Surge was reliable and valid for all conditions except for treadmill walking (deemed reliable, ICC = 0.76; but not valid). The Polar A360 was found to be reliable for one condition (treadmill jog ICC = 0.78), but not valid for any condition. The Garmin Vivosmart HR+ and Leaf Health Tracker were found to be both reliable and valid for all situations. While each device returned some level of consistency and accuracy during either free motion or treadmill exercises, the Garmin Vivosmart HR+ and the Leaf Health Tracker were deemed to be reliable and valid for all conditions tested.

1 January 2019 in International Journal of Exercise Science
Verified
Journal Article
Closed access
PDF file
JMJeffrey Montes
Jeffrey Montes
James W NavaltaJames W Navalta
James W Navalta
The Polar T31 uncoded heart rate monitor (T31) is currently accepted as a precision measurement device that can be used in lieu of electrocardiography. However, minimal literature exists to verify reliability when used for this purpose. The purpose of this study is to evaluate the reliability of heart rate (HR) measurements obtained from the T31. Forty volunteers participated in a three-day test-retest protocol. Participants gave anthropometric data on the first day. On the second day, they performed two 5-minute self-paced free motion walks (FMW) and two 5-minute self-paced free motion jogs (FMJ). Finally, on the third day, they performed two 5-minute treadmill walks (TW) and two 5-minute treadmill jogs (TJ). Treadmill speeds for each TW and TJ were determined by the distances traveled during the FMWs and FMJs on day 2. HR values at rest (HRR) and while in motion (minutes 1-5) were evaluated (HRM). Values calculated used Cronbach’s α (≥0.70) for reliability with significance accepted at p<0.05. FMW HRR (all, α=0.96; male, α=0.97; female, α=0.94), FMJ HRR (all, α=0.98; male, α=0.98; female, α=0.99), TW HRR (all, α=0.96; male; α=0.92; female, α=0.98), TJ HRR (all, α=0.97; male, α=0.98; female, α=0.96), FMW HRM (all, α=0.93; male, α=0.93; female, α=0.91), FMJ HRM (all, α=0.93; male, α=0.94; female, α=0.90), TW HRM (all, α=0.95; male, α=0.92; female, α=0.95), TJ HRM (all, α=0.94; male, α=0.95; female, α=0.92). All p-values < 0.001. The T31 provided reliable measures at rest and for walking and jogging in both a free motion and treadmill setting.

1 January 2018 in International Journal of Exercise Science
Verified
Journal Article
Open access
PDF file
James W NavaltaJames W Navalta
James W Navalta
JMJeffrey Montes
Jeffrey Montes
ETElizabeth A. Tanner
Elizabeth A. Tanner
NBNathaniel Bodell
Nathaniel Bodell
JYJohn C. Young
John C. Young
International Journal of Exercise Science 11(6): 281-289, 2018. Female participation is growing in trail running races. The purpose was to evaluate sex and age differences in top finishers of a trail running half marathon. Velocity differences between males (M) and females (F) were determined for the top 10 finishers of the Moab Trail Half Marathon from 2012 - 2015 across age, and by finishing place. Differences between age category and between sexes were determined through ANOVA with significance accepted at P < 0.05. A significant difference for running velocity was present between sexes at each age category (20-29 yr F = 2.9±0.3, M = 3.4±0.4 m·sec-1; 30-39 yr F = 2.8±0.3, M = 3.3±0.3; 40-49 yr F = 2.7±0.3, M = 3.0±0.5; 50-59 yr F = 2.3±0.2, M = 2.8±0.3; 60-69 yr F = 1.6±0.3, M = 2.2±0.4; P < 0.0001). Sex difference in trail running velocity was consistent (~13%) among all age categories with exception of the oldest group (33%, P = 0.0001). There were significantly greater female finishers in every age category (20 - 29 yr F = 107±18, M = 56±1;, 30 - 39 yr F = 150±34, M = 84±21; 40 - 49 yr F = 112±17, M = 64±16; P < 0.01) until 50 - 59 yr (F = 48±13, M = 41±14; P = 0.50). These data indicate that the widening gap in sex differences observed in road races are ameliorated in a trail running environment that has a larger number of female participants.