17 January 2023 in IEEE Transactions on Industrial Electronics
Continuum manipulators have infinite degrees of freedom and high flexibility, making it challenging for accurate modeling and control. Some common modeling methods include mechanical modeling strategy, neural network strategy, constant curvature assumption, etc. However, the inverse kinematics of the mechanical modeling strategy is difficult to obtain while a strategy using neural networks may not converge in some applications. For algorithm implementation, the constant curvature assumption is used as the basis to design the controller. When the driving wire is tight, the linear controller under constant curvature assumption works well in manipulator position control. However, this assumption of linearity between the deformation angle and the driving input value breaks upon repeated use of the driving wires which get inevitably lengthened. This degrades the accuracy of the controller. In this work, the Koopman theory is used to identify the nonlinear model of the continuum manipulator. Under the linearized model, the control input is obtained through model predictive control (MPC). As the lifted function can affect the effectiveness of the Koopman operator-based MPC (K-MPC), a novel design method of the lifted function through the Legendre polynomial is proposed. To attain higher control efficiency and computational accuracy, we use a selective control scheme according to the state of the driving wires. When the driving wire is tight, the linear controller is employed; otherwise, the K-MPC is adopted. Finally, a set of static and dynamic experiments have been conducted using an experimental prototype. The results demonstrate high effectiveness and good performance of the selective control scheme.
10 August 2020 in IEEE/ASME Transactions on Mechatronics
The laryngeal surgery is usually performed with rigid surgical instruments. However, those instruments inevitably cause tissue damage. A novel notch continuum manipulator for laryngeal surgery is proposed. The deformation of the notch continuum manipulator is highly nonlinear. The controller is difficult to construct. The model-based modeling strategy from micro to macro is adopted for accurate modeling. The proposed notch continuum manipulator is modeled as a series of flexible units. Based on the mechanical model and Denavit-Hartenberg(D-H) method, the mapping from the driven space to the Cartesian space is constructed. The model-free strategy based on the forward kinematics and machine learning is adopted to provide an approximate solution for the inverse kinematics. Therefore, combining the advantages of model-free and model-based strategies, a hybrid method can be proposed to accurately model and solve the kinematics of a class of continuum manipulators. The experimental results obtained through the prototype show that the proposed controller model can meet the actual engineering requirement.
18 May 2020 in International Journal of Control, Automation, and Systems
19 August 2021 in IEEE Transactions on Instrumentation and Measurement
The laryngeal tissue is sensitive to the operating force of the surgical instrument in the tissue resection. A large operating force may cause rupture of the vocal cords and surrounding tissues, which affect the patients’ normal voice. However, a small operating force cannot achieve tissue resection. Based on experience, surgeons can estimate the operating force in the process of using a surgical robot. The estimated operating force is usually inaccurate, which may increase the failure rate of surgery. Therefore, a fiber Bragg gratings (FBGs)-based 3-D force sensing sensor for the surgical robot, which consists of two flexible hinges in series is designed. And the force sensing model is constructed through mechanical modeling and temperature decoupling algorithm. The experimental results show that the designed sensor has a resolution of 14.3, 9.7, and 13.8 mN for external forces ${F_{x}},{F_{y}}$ , and ${F_{z}}$ , respectively. The proposed mechanism has good axial and lateral force sensing capability. In the experiment of simulating diseased tissue with the silicone-steel ball, the designed sensor can accurately determine the position of the steel ball, which verifies the effectiveness and feasibility of the designed FBG sensor in force perception.
4 June 2024 in Signal, Image and Video Processing
6 April 2023 in IEEE Transactions on Instrumentation and Measurement
An instrument usually is installed at the distal end of a continuum surgical robot to perform specific tasks. The driving wire of the instrument needs to pass through the central channel of the continuum robot. And force perception of the continuum robot is often lacking. Based on this application background, a novel Fiber Bragg Gratings (FBG)-based 3-D force sensor is proposed. This sensor consists of an axial force perceptive zone and a radial force perceptive zone. Four optical fibers with dual FBG nodes are arranged to the sensor. Thanks to the novel arrangement of FBGs, one central channel is retained to arrange the driving wire of the instrument. A novel force perceptive model is established through the temperature decoupling algorithms and Bernoulli-Euler beam theory. Calibration experiments show that the proposed sensor can achieve a resolution of 1.9 mN, 2.4 mN, and 9.8 mN for Fx , Fy and Fz , respectively. Dynamic performance and temperature decoupling algorithms show that the proposed FBG sensor can accurately realize 3-D force perception.