In 2010, the NCS (Netherlands Commission on Radiation Dosimetry) installed a subcommittee to develop guidelines for quality assurance and control for volumetric modulated arc therapy (VMAT) treatments. The report (published in 2015) has been written by Dutch medical physicists and has therefore, inevitably, a Dutch focus. This paper is a condensed version of these guidelines, the full report in English is freely available from the NCS website www.radiationdosimetry.org . After describing the transition from IMRT to VMAT, the paper addresses machine quality assurance (QA) and treatment planning system (TPS) commissioning for VMAT. The final section discusses patient specific QA issues such as the use of class solutions, measurement devices and dose evaluation methods.
17 July 2017 in Physics in Medicine & Biology
In external beam radiotherapy, electronic portal imaging devices (EPIDs) are frequently used for pre-treatment and for in vivo dose verification. Currently, various MR-guided radiotherapy systems are being developed and clinically implemented. Independent dosimetric verification is highly desirable. For this purpose we adapted our EPID-based dose verification system for use with the MR-Linac combination developed by Elekta in cooperation with UMC Utrecht and Philips. In this study we extended our back-projection method to cope with the presence of an extra attenuating medium between the patient and the EPID. Experiments were performed at a conventional linac, using an aluminum mock-up of the MRI scanner housing between the phantom and the EPID. For a 10 cm square field, the attenuation by the mock-up was 72%, while 16% of the remaining EPID signal resulted from scattered radiation. 58 IMRT fields were delivered to a 20 cm slab phantom with and without the mock-up. EPID reconstructed dose distributions were compared to planned dose distributions using the -evaluation method (global, 3%, 3 mm). In our adapted back-projection algorithm the averaged was , while in the conventional it was . Dose profiles of several square fields reconstructed with our adapted algorithm showed excellent agreement when compared to TPS.
20 January 2022 in Physics and Imaging in Radiation Oncology
Dosimetric patient-Specific Quality Assurance (PSQA) data contain in addition to cases with alerts, many cases without alerts. The aim of this study was to present a procedure to investigate long-term trend analysis of the complete set of PSQA data for the presence of site-specific deviations to reduce underlying systematic dose uncertainties. The procedure started by analysing a large set of prostate Volumetric Modulated Arc Therapy (VMAT) PSQA data obtained by comparing 3D electronic portal image device (EPID)_based in vivo dosimetry measurements with dose values predicted by the Treatment Planning System (TPS). If systematic deviations were present, several actions were required. These included confirmation of these deviations with an independent dose verification system for which a 2D detector array in a phantom was used, and analysing calculated with measured PSQA data, or delivery machine characteristics. Further analysis revealed that the under-dosage correlated with plan complexity and coincided with changes in clinically applied planning techniques. Prostate VMAT PSQA data showed an under-dosage gradual increasing to about 2% in 3 years, which was confirmed by the measurements with the 2D detector array in a phantom. The implementation of new beam fits in the TPS led to a reduction of the observed deviations. Long-term analysis of site-specific PSQA data is a useful method to monitor incremental changes in a radiotherapy department due to various changes in the treatment planning and delivery of prostate VMAT, and may lead to a reduction of systematic dose uncertainties in complex treatments.
13 January 2021 in Medical Physics