Alexander D. Smith

Alexander D. Smith

Auto-generated profile, based on publicly available information

Alexander D. Smith

Siebel School of Computing and Data Science, University of Illinois Urbana-Champaign, 201 N Goodwin Ave., Urbana, IL 61801, USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 February 2022 in IEEE Robotics and Automation Letters
Verified
Journal Article
Open access
YZYifan Zhu
Yifan Zhu
ASAlexander Smith
Alexander Smith
KHKris Hauser
Kris Hauser
This letter presents the first implementation of autonomous robotic auscultation of heart and lung sounds. To select auscultation locations that generate high-quality sounds, a Bayesian Optimization (BO) formulation leverages visual anatomical cues to predict where high-quality sounds might be located, while using auditory feedback to adapt to patient-specific anatomical qualities. Sound quality is estimated online using machine learning models trained on a database of heart and lung stethoscope recordings. Experiments on 4 human subjects show that our system autonomously captures heart and lung sounds of similar quality compared to tele-operation by a human trained in clinical auscultation. Surprisingly, one of the subjects exhibited a previously unknown cardiac pathology that was first identified using our robot, which demonstrates the potential utility of autonomous robotic auscultation for health screening.

11 November 2020 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Open access
ASAlexander D. Smith
Alexander D. Smith
JCJacob Chapin
Jacob Chapin
PBPaul V. Birinyi
Paul V. Birinyi
PBPrathamesh V. Bhagvath
Prathamesh V. Bhagvath
AHAndrew Hall
Andrew Hall
Robotic spine surgery systems, used for placing pedicle screws, have been in clinical use since 2004; however, these systems act only as a positioner for guide tubes, which the surgeon uses to manually advance tools to prepare the site and place hardware (e.g. pedicle screws). This paper presents the development, operation, and evaluation of a new, commercial-robot-based, image-guided surgery system that automates the process of bone preparation and polyaxial screw placement. The system is based on the KUKA LBR iiwa 7-axis collaborative robot. Fiducial marker and screw locations are defined on a pre-operative CT image using the 3D Slicer open source image visualization platform. The system uses the robot’s internal localization system for registration, by touching fiducial markers in a hand-guiding mode. A rotary-motor end effector with exchangeable tools is used for both hole-drilling and screw placement. A novel single-motor based mechanism was developed for placing polyaxial pedicle screws. An accuracy test was performed by placing polyaxial screws in synthetic vertebrae which mimic the mechanical properties of human bone. In placing 10 screws, the entry point accuracy was 0.49 ± 0.17 mm and the destination point accuracy was 1.49 ± 0.46 mm. The results compare favorably to evaluations of commercial robotic spine surgery systems.

17 June 2025 in PLOS ONE
Verified
Journal Article
Open access
PDF file
TNTyler B. Nofzinger
Tyler B. Nofzinger
THTimothy T. Huang
Timothy T. Huang
CLChristopher Eduard R. Lingat
Christopher Eduard R. Lingat
GAGaurang M. Amonkar
Gaurang M. Amonkar
EEEmily E. Edwards
Emily E. Edwards
HGHeidi L. Gaddey
Heidi L. Gaddey
Introduction: Influenza vaccination is a critical public health measure, especially amidst the challenges of the COVID-19 pandemic. This study uses Epic’s Cosmos database to analyze influenza vaccination trends across demographic groups in the United States, examining the effects of the COVID-19 pandemic and “vaccine fatigue” on influenza vaccination rates. Methods: This retrospective cross-sectional study analyzes influenza vaccination rates pre- (1 May 2018–31 May 2019), peri- (1 May 2020–31 May 2021), and post-COVID-19 (1 May 2023–31 May 2024). A two-proportion z-test and Cohen’s h test were calculated to assess statistical significance. Results: Influenza vaccination rates increased peri-COVID (+1.99% point change, h = 0.04, p < 0.001) and decreased post-COVID (−6.41% point change, h = 0.14, p < 0.001) relative to pre-COVID. The largest changes were observed in the following groups: 5−18 year olds (−13.92% point change, h = 0.31, p < 0.001), 19−26 year olds (−9.91% point change, h = 0.25, p < 0.001), American Indian or Alaska Native (−8.11% point change, h = 0.18, p < 0.001), Other Races (−7.36% point change, h = 0.17, p < 0.001), White (−6.89% point change, h = 0.15, p < 0.001), and the South U.S. census region (−7.21% point change, h = 0.17, p < 0.001). Conclusion: Post-pandemic influenza vaccination compliance decreased relative to pre-pandemic, especially among younger age groups, certain racial groups, and in the southern U.S. These findings suggest that the COVID-19 pandemic negatively impacted influenza vaccination compliance. While overall trends aligned with publicly available data, absolute counts may be under-reported within Epic due to incomplete documentation of vaccine administrations outside of Epic-affiliated systems.


26 May 2025 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Open access
ASAlexander D. Smith
Alexander D. Smith
ANAnant Naik
Anant Naik
SPSuguna Pappu
Suguna Pappu
PAPaul M. Arnold
Paul M. Arnold
KHKris Hauser
Kris Hauser
Objective: This paper proposes a low-cost realtime navigation system to assist a surgeon in placing external ventricular drains. Methods: In our approach, the base of an articulated arm coordinate measuring machine is bolted to the patients skull, and a graphical user interface quickly guides the operator through the image registration and 3D navigation to place an external ventricular drain at a desired target specified relative to preoperative imaging. The method can be employed in workflows with and without fiducials embedded in the preoperative imaging. Results: The proposed system is evaluated using precise registration instruments, human phantom models, and ex vivo ovine models, demonstrating less than 2mm of error with fiducials and less than 4mm of error without fiducials. Conclusion: The registration procedure takes less than one minute and can be performed intuitively by a single operator without an assistant. Significance: Our proposed system enables real-time image-guided navigation to be used in bedside external ventricular drain placement, with potential to expand access to this procedure.

14 January 2026 in Journal of Medical Robotics Research
Verified
Journal Article
Closed access
ASAlexander D. Smith
Alexander D. Smith
WDWenzhou Ding
Wenzhou Ding
LVLorenzo Vianello
Lorenzo Vianello
EPErica Person
Erica Person
KHKris Hauser
Kris Hauser