Kai Ye

Kai Ye

Auto-generated profile, based on publicly available information

Kai Ye

State Key Laboratory of Electrical Insulation and Power Equipment, Xian Jiaotong University, Xian, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 October 2023 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
KYKai Ye
Kai Ye
ZLZhu Liu
Zhu Liu
CLChujun Liu
Chujun Liu
Aijun YangAijun Yang
Aijun Yang
Huan YuanHuan Yuan
Huan Yuan
Xiaohua WangXiaohua Wang
Xiaohua Wang
Magnetic field energy harvester (MEH) based on current transformers has emerged as a promising method for powering mass sensors in smart grids. However, a significant challenge lies in the insufficient power harvested at low primary currents. Aiming at resolving this shortcoming, a novel maximum power point reaching method based on a low-power analog control circuit is proposed in the present study. The main objective of this method is to improve the performance of the MEH. The maximum power point is achieved by controlling the voltage of the DC side of the rectifier bridge based on the optimal load voltage characteristics of the MEH. The analog control circuit is designed using low-power analog devices and megaohm-level resistors, eliminating the need for a microcontroller. The performed analyses revealed that the calculated maximum power loss of the proposed approach is only 81.81 μW. Experimental results demonstrate a remarkable increase in MEH power output ranging from 101.39% to 149.89% compared to commercial circuits at currents ranging from 1A to 10A.

1 November 2021 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
FFFulai Fan
Fulai Fan
XTXuesong Tang
Xuesong Tang
WJWang Jianming
Wang Jianming
YXYunkai Xiao
Yunkai Xiao
ZYZhutao Yin
Zhutao Yin
JMJianchao Ma
Jianchao Ma
In order to reduce the occurrence of power outages with repeated occurrences in the distribution network, this paper first defines the quantitative index of the concept of repeated occurrences. The FP-Growth data mining algorithm based on the optimal frequent itemset is proposed to obtain the correlation between the power outage factors. Combined with the fuzzy analytic hierarchy process, the main reasons for repeated power outages are obtained. The analytic hierarchy process combining subjective and objective weights is used to comprehensively evaluate the risk of repeated power outages in the distribution network. This paper realizes the early warning of power outage risk based on the comprehensive probability value of power outage. Finally, an actual distribution network in Chongqing is taken as an example to verify the practicability and effectiveness of the method.

19 September 2022 in arXiv
Verified
Preprint
Open access
PDF file
HKHyeon-Jin KIM
Hyeon-Jin KIM
KYKai Ye
Kai Ye
HLHan Pyo Lee
Han Pyo Lee
RHRongxing Hu
Rongxing Hu
NLNing Lu
Ning Lu
PRPj Rehm
Pj Rehm
This paper presents an independent component analysis (ICA) based unsupervised-learning method for heat, ventilation, and air-conditioning (HVAC) load disaggregation using low-resolution (e.g., 15 minutes) smart meter data. We first demonstrate that electricity consumption profiles on mild-temperature days can be used to estimate the non-HVAC base load on hot days. A residual load profile can then be calculated by subtracting the mild-day load profile from the hot-day load profile. The residual load profiles are processed using ICA for HVAC load extraction. An optimization-based algorithm is proposed for post-adjustment of the ICA results, considering two bounding factors for enhancing the robustness of the ICA algorithm. First, we use the hourly HVAC energy bounds computed based on the relationship between HVAC load and temperature to remove unrealistic HVAC load spikes. Second, we exploit the dependency between the daily nocturnal and diurnal loads extracted from historical meter data to smooth the base load profile. Pecan Street data with sub-metered HVAC data were used to test and validate the proposed methods.Simulation results demonstrated that the proposed method is computationally efficient and robust across multiple customers.