In this study, acid-activated multi-walled carbon nanotubes (AA-MWCNT) and poly(3,4-ethylenedioxythiophene) (PEDOT) were deposited on a pencil graphite electrode (PGE) surface for electrochemical sensing applications. The acid-activated multi-walled carbon nanotube/over-oxidized poly(3,4-ethylenedioxythiophene) modified pencil graphite electrode (AA-MWCNT/OO-PEDOT/PGE) was characterized using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX) and X-ray photoelectron spectroscopy (XPS). The sensing properties of the obtained surface were examined for the voltammetric determination of serotonin in a phosphate buffer solution. The effects of the pH, adsorption time, over-oxidation and polymerization parameters on the electrochemical properties of serotonin were investigated. The effects of possible interfering substances were evaluated. The detection limit was determined to be 0.092 µM based on a signal-to-noise ratio of 3. Analytical applications of AA-MWCNT/OO-PEDOT/PGE were successfully tested for the determination of serotonin in human blood serum samples.
25 November 2020 in ECS Journal of Solid State Science and Technology
In this study; an easy, practical, and selective sensor has been developed for the electrochemical determination of riboflavin. To prepare the modified electrode, the gold nanoparticle was deposited on the pencil graphite electrode (AuNP/PGE) by the method of chronoamperometry at −3.0 V for 30 s in 0.5 M H 2 SO 4 solution containing 10 mM tetrachloroaurate. Functionalized multi-walled carbon nanotube (f-MWCNT) solution was dropped on prepared AuNP/PGE and the functionalized multi-walled carbon nanotube/gold nanoparticle/pencil graphite electrode (f-MWCNT/AuNP/PGE) was prepared for measurements. Characterization studies of the prepared sensor were performed using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), energy-dispersive X-ray spectroscopy (EDX), and X-ray photoelectron spectroscopy (XPS) methods. The surface morphology of the prepared sensor was investigated by field emission scanning electron microscopy (FESEM). Differential pulse voltammetry (DPV) was used to carry out electrochemical measurements in phosphate buffer solution pH 4.0. Limit of detection (LOD) and limit of quantitation (LOQ) values were found to be 0.0352 and 0.118 μ mol l −1 , respectively. The fabricated sensor showed excellent anti-interference ability against ascorbic acid (AA) and glucose (G). The applicability of the constructed sensor to real samples was investigated and good recovery values were achieved. As a result, it has been seen that the modified electrode is applicable in applications of riboflavin determination.
Supercapacitors (SCs) are the most interesting alternative energy storage and conversion systems to successfully overcome the global energy problem for future generations. A lot of work has been done to improve the capacitive performance of an electrode and to achieve high power and energy density. Herein, for the first time in the literature, we prepared hybrid composite materials consisting of metallo phthalocyanine doped-titanium dioxide (MPc-TiO2) and high conductivity graphene (Gr) and polyaniline (PANI) in a one-step on pencil graphite electrode (PGE) using the cyclic voltammetry method. The microscopic and structural characteristics of the synthesized MPc-TiO2/Gr/PANI/PGE (M=Cu and Co) are analyzed by various spectroscopic and analytical techniques. As a result, the optimized CoPc-TiO2/Gr/PANI/PGE as the electrode shows a highly specific capacitance of 401.5 F g−1 at 5 A g−1 and excellent cyclic stability up to 1000 cycles. The good electrochemical performance could be attributed to the synergistic effect of the high pseudocapacitance and good conductivity of CoPc-TiO2 as well as the capacitive contribution and conductivity of Gr and PANI. Our strategy provides a new avenue to develop high-performance SCs via rational integration of MPc-TiO2 with Gr and PANI.
20 April 2021 in International Journal of Environmental Analytical Chemistry
In this study, an anodically pretreated pencil graphite electrode (Ptre/PGE) which has oxygen-containing groups was used for the electrochemical determination of Allura Red (AR) by differential pulse voltammetry (DPV) method for the first time in the literature. In order to be more selective and sensitive the pencil graphite electrode, the anodic pretreatment process was performed by applying a constant +1.8 V potential for 250 s in pH 9 phosphate buffer solution using chronoamperometry method. The characterisation studies of the sensor were performed using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), and atomic force microscopy (AFM) methods. Interference effects of sunset yellow, tartrazine, amaranth, aspartame, glucose, gelatin, and ascorbic acid on AR determination with Ptre/PGE were investigated. The limit of detection and quantitation values was found as 75 and 251 nmol L−1, respectively. The Ptre/PGE has been used for the determination of AR in cherry juice and energy drink samples, where it provides recovery ranging from 98.40% to 100.8%.