Magnus Karlsteen

Magnus Karlsteen

Auto-generated profile, based on publicly available information

Magnus Karlsteen

Chalmers University of Technology

Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 May 2001 in Applied Physics Letters
Verified
Journal Article
Closed access
JSJ. Sadowski
J. Sadowski
RMR. Mathieu
R. Mathieu
PSP. Svedlindh
P. Svedlindh
JDJ. Z. Domagała
J. Z. Domagała
JBJ. Bak-Misiuk
J. Bak-Misiuk
USU. Södervall
U. Södervall
Ferromagnetic GaMnAs containing up to 10% Mn has been grown by migration-enhanced epitaxy at a substrate temperature of 150 °C. The lattice constant of hypothetical zinc-blende structure MnAs is determined to be 5.90 Å, which deviates somewhat from previously reported values. This deviation is ascribed to growth-condition-dependent density of point defects. Magnetization measurements showed an onset of ferromagnetic ordering around 75 K for the GaMnAs layer with 10% Mn. This means that the trend of falling Curie temperatures with increasing Mn concentrations above 5.3% is broken.

13 July 1999 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
RKR. N. Kyutt
R. N. Kyutt
ATA. A. Toropov
A. A. Toropov
SSS. V. Sorokin
S. V. Sorokin
TST. V. Shubina
T. V. Shubina
SIS. V. Ivanov
S. V. Ivanov
MWM. Willander
M. Willander
We present x-ray diffraction studies of a CdSe distribution profile along the growth direction in CdSe/ZnSe submonolayer superlattices (SLs) grown by molecular beam epitaxy. The performed theoretical simulations show that the shape of both (004)- and (002)-reflection rocking curves is very sensitive to the vertical CdSe distribution around the intended deposition yplanes. In particular, broadening of the CdSe submonolayer insertions results in a decrease in SL (±1) and (±2) satellite intensities. Comparison of the simulations and experimental data allows us to conclude that CdSe sheets in the as-grown SL samples are asymmetrically broaden up to 5 monolayers.

1 December 2017 in International Journal of Heat and Mass Transfer
Verified
Journal Article
Closed access
BMB.M. Mihiretie
B.M. Mihiretie
DCD. Cederkrantz
D. Cederkrantz
ARA. Rosén
A. Rosén
HOH. Otterberg
H. Otterberg
MSM. Sundin
M. Sundin
MKM. Karlsteen
M. Karlsteen

22 November 1999 in Physica Status Solidi (a)
Verified
Journal Article
Closed access
PDF file
VMV. V. Mamutin
V. V. Mamutin
VVV. A. Vekshin
V. A. Vekshin
VDValery Davydov
Valery Davydov
VRV. V. Ratnikov
V. V. Ratnikov
TST. V. Shubina
T. V. Shubina
MWM. Willander
M. Willander

14 October 2002 in Applied Physics Letters
Verified
Journal Article
Closed access
RMR. Mathieu
R. Mathieu
PSP. Svedlindh
P. Svedlindh
JSJ. Sadowski
J. Sadowski
KŚK. Światek
K. Światek
MKM. Karlsteen
M. Karlsteen
LIL. Ilver
L. Ilver
Magnetic properties of (Ga,Mn)As/GaAs superlattices are investigated. The structures contain magnetic (Ga,Mn)As layers, separated by thin layers of nonmagnetic GaAs spacer. The short-period Ga0.93Mn0.07As/GaAs superlattices exhibit a paramagnetic-to-ferromagnetic phase transition close to 60 K, for thicknesses of (Ga,Mn)As down to 23 Å. For Ga0.96Mn0.04As/GaAs superlattices of similar dimensions, the Curie temperature associated with the ferromagnetic transition is found to oscillate with the thickness of nonmagnetic spacer. The observed oscillations are related to an interlayer exchange interaction mediated by the polarized holes of the (Ga,Mn)As layers.

1 January 2016 in Procedia Engineering
Verified
Journal Article
Open access
JLJanna Brit Langholz
Janna Brit Langholz
GWGunnar Westman
Gunnar Westman
MKMagnus Karlsteen
Magnus Karlsteen
Previous swim start measurements at Chalmers University of Technology involved electromyography (EMG) in order to get an overall picture of the muscle activation pattern during the swim start. In order to fully evaluate sports performance trainers may facilitate additional tools, like videography and force plates, to be able to underpin the feedback given to the athletes. However, the output of the different tools are often complicated and lengthy to handle. Therefore it would be valuable to find an easily applicable tool to visualize biomechanical data. Feedback to athletes based on scientifically measured variables would then ideally be more efficient and effective. This paper evaluates three different software tools regarding musculoskeletal modelling and simulation with quick, meaningful and unambiguous data processing and presentation: OpenSim, BoB and AnyBody. The software package SWUM was also analyzed as it is currently the only tool that can model forces and buoyancy during swimming. It has been found that OpenSim is a beneficial tool for academic projects as it is freely available and provides a big pool of users and papers available to support the user with additional knowledge. BoB is the most straight-forward tool being appropriate for biomechanical teaching and applications where a fast analysis is required. AnyBody has the most sophisticated model which can be adjusted to the users demands in great detail and is favorable for investigations with focus on the interaction between the body and the environment or a detailed medical analysis. Great potential lies in the further development and usage of SWUM as its basic interface with valuable outputs and simulations as well as the possibility of connecting to AnyBody might allow for advancements in swim training