Murat Tolga Gulpinar

Murat Tolga Gulpinar

Auto-generated profile, based on publicly available information

Murat Tolga Gulpinar

Department of Urology, Çanakkale Onsekiz Mart University, Çanakkale, Turkey

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 August 2015 in Inflammation
Verified
Journal Article
Closed access
PDF file
ESEyup Burak Sancak
Eyup Burak Sancak
HTHakan Turkön
Hakan Turkön
SÇSelma Çukur
Selma Çukur
SESevilay Erimsah
Sevilay Erimsah
AAAlpaslan Akbas
Alpaslan Akbas
MUMetehan Uzun
Metehan Uzun

1 November 2005 in Journal of Urology
Verified
Journal Article
Closed access
AYAsif Yildirim
Asif Yildirim
EBErem Kaan Basok
Erem Kaan Basok
TGTolga Gulpinar
Tolga Gulpinar
CGCenk Gurbuz
Cenk Gurbuz
EZEbru Zemheri
Ebru Zemheri
RTResit Tokuc
Resit Tokuc
We evaluated tissue reactions to 5 sling materials used in tension-free vaginal tape (TVT), intravaginal slingplasty (IVS), polypropylene mesh hernia repair, the suprapubic approach to suburethral polypropylene tape (SPARC) and cadaveric fascia lata procedures. We also compared the mesh-to-tissue attachment strength of 4 sling mesh materials (TVT, IVS, surgical polypropylene mesh and SPARC) at on days 2, 7, 15 and 30 after implantation. A total of 20 female New Zealand White rabbits were randomized to group 1-2 days, group 2-7 days, group 3-15 days and group 4-30 days. After the rabbits were anesthetized an 8 cm midline incision was made for rectus muscle access, and 0.5 x 1 cm pieces of TVT, IVS, SPARC, surgical polypropylene mesh and cadaveric fascia lata were sewn to the rectus muscle with direct contact. At the same time 4 subfascial tunnels in the medial surface of the upper extremities were prepared, and 1.0 x 0.5 cm strips of TVT, IVS, SPARC and polypropylene mesh were implanted in each tunnel. On days 2, 7, 15 and 30 after implantation mechanical testing was performed to define tissue detachment strength. The strips of 5 sling materials were then harvested with the surrounding tissue. Specimens were studied by light microscopy. Mean detachment strength, that is the minimum weight needed to move the mesh, of the synthetic meshes from days 2 to 30 were 291.6 to 2,390.0 gm for TVT, 178.4 to 2,160.0 gm for SPARC, 188.4 to 1,850.0 gm for hernia mesh and 92.8 to 1,510.0 gm for IVS (at all data points TVT vs IVS p < 0.05). Light microscopy revealed a quite uniform tissue reaction with a sign of marked acute inflammation in and around the mesh fibers on days 2 and 7 after implantation. All meshes showed stable fibrosis and muscle infiltration on day 30. All 5 synthetic sling materials produce similar tissue reactions beginning soon after implantation. Cadaveric fascia lata persisted in tissue with remarkable perifascial fibrosis at day 30. When comparing the 4 polypropylene mesh materials; the attachment capacity of TVT was superior and that of IVS was the least of the 4. TVT was statistically better than IVS at all data points. SPARC and hernia mesh provided results similar to those of TVT.

13 October 2015 in Renal Failure
Verified
Journal Article
Closed access
PDF file
AAAlpaslan Akbas
Alpaslan Akbas
MGMurat Tolga Gulpinar
Murat Tolga Gulpinar
ESEyup Burak Sancak
Eyup Burak Sancak
TKTolga Karakan
Tolga Karakan
ADArif Demirbas
Arif Demirbas
BRBerkan Resorlu
Berkan Resorlu
The effect of music therapy during shockwave lithotripsy on patient relaxation, anxiety, and pain perception. . ???aop.label???. doi: 10.3109/0886022X.2015.1096728

19 April 2014 in The Kaohsiung Journal of Medical Sciences
Verified
Journal Article
Closed access
BEBulent Erol
Bulent Erol
MGMurat Tolga Gulpinar
Murat Tolga Gulpinar
GBGurdal Bozdogan
Gurdal Bozdogan
SOSeyma Ozkanli
Seyma Ozkanli
KOKadir Onem
Kadir Onem
AMAydin Mungan
Aydin Mungan

20 May 2015 in Inflammation
Verified
Journal Article
Closed access
PDF file
AAAlpaslan Akbas
Alpaslan Akbas
CSCoskun Silan
Coskun Silan
MGMurat Tolga Gulpinar
Murat Tolga Gulpinar
ESEyup Burak Sancak
Eyup Burak Sancak
SOSidika Seyma Ozkanli
Sidika Seyma Ozkanli
DCDilek Ulker Cakir
Dilek Ulker Cakir

28 April 2015 in Pakistan Journal of Medical Sciences
Verified
Journal Article
Open access
PDF file
ESEyup Burak Sancak
Eyup Burak Sancak
MRMustafa Resorlu
Mustafa Resorlu
AAAlpaslan Akbas
Alpaslan Akbas
MGMurat Tolga Gulpinar
Murat Tolga Gulpinar
MAMuhammet Arslan
Muhammet Arslan
BRBerkan Resorlu
Berkan Resorlu
Objective: In this study we planned to investigate the relationship between presence of kidney stones and stone burden with hypertension (HT), diabetes mellitus (DM) and body mass index (BMI).Methods: A total of 574 patients were included in the study. None of the patients had a history of stones. The 121 patients with kidney stone identified on ultrasound evaluation and the 453 patients with no stones were compared in terms of HT, BMI and DM. The stone burden of 121 patients with diagnosed stones was compared in terms of the same variables.Results: Of the 121 patients with kidney stones 30 (24.7%) had HT, while 66 (14.5%) of the 453 patients without stones had HT (p=0.007). BMI values of those with and without stones were 27.2