Stefano E. Romero

Stefano E. Romero

Auto-generated profile, based on publicly available information

Stefano E. Romero

Pontificia Universidad Catlica del Peru,Laboratorio de Imgenes Mdicas,Lima,Peru

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2005 in Resuscitation
Verified
Journal Article
Closed access
RLRiccardo Lubrano
Riccardo Lubrano
SRStefano Romero
Stefano Romero
PSPietro Scoppi
Pietro Scoppi
GCGuido Cocchi
Guido Cocchi
SBSimonetta Baroncini
Simonetta Baroncini
RMRossella Moscatelli
Rossella Moscatelli

23 November 2022 in PLOS Digital Health
Verified
Journal Article
Open access
PDF file
TMThomas J Marini
Thomas J Marini
BCBenjamin Castaneda
Benjamin Castaneda
KPKevin Parker
Kevin Parker
TBTimothy M Baran
Timothy M Baran
SRStefano Romero
Stefano Romero
AOAvice O'Connell
Avice O'Connell
Breast ultrasound provides a first-line evaluation for breast masses, but the majority of the world lacks access to any form of diagnostic imaging. In this pilot study, we assessed the combination of artificial intelligence (Samsung S-Detect for Breast) with volume sweep imaging (VSI) ultrasound scans to evaluate the possibility of inexpensive, fully automated breast ultrasound acquisition and preliminary interpretation without an experienced sonographer or radiologist. This study was conducted using examinations from a curated data set from a previously published clinical study of breast VSI. Examinations in this data set were obtained by medical students without prior ultrasound experience who performed VSI using a portable Butterfly iQ ultrasound probe. Standard of care ultrasound exams were performed concurrently by an experienced sonographer using a high-end ultrasound machine. Expert-selected VSI images and standard of care images were input into S-Detect which output mass features and classification as “possibly benign” and “possibly malignant.” Subsequent comparison of the S-Detect VSI report was made between 1) the standard of care ultrasound report by an expert radiologist, 2) the standard of care ultrasound S-Detect report, 3) the VSI report by an expert radiologist, and 4) the pathological diagnosis. There were 115 masses analyzed by S-Detect from the curated data set. There was substantial agreement of the S-Detect interpretation of VSI among cancers, cysts, fibroadenomas, and lipomas to the expert standard of care ultrasound report (Cohen’s κ = 0.73 (0.57–0.9 95% CI), p<0.0001), the standard of care ultrasound S-Detect interpretation (Cohen’s κ = 0.79 (0.65–0.94 95% CI), p<0.0001), the expert VSI ultrasound report (Cohen’s κ = 0.73 (0.57–0.9 95% CI), p<0.0001), and the pathological diagnosis (Cohen’s κ = 0.80 (0.64–0.95 95% CI), p<0.0001). All pathologically proven cancers (n = 20) were designated as “possibly malignant” by S-Detect with a sensitivity of 100% and specificity of 86%. Integration of artificial intelligence and VSI could allow both acquisition and interpretation of ultrasound images without a sonographer and radiologist. This approach holds potential for increasing access to ultrasound imaging and therefore improving outcomes related to breast cancer in low- and middle- income countries.

5 May 2023 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
ATAldo Tecse
Aldo Tecse
SRStefano E Romero
Stefano E Romero
Roozbeh RoozbehRoozbeh Roozbeh
Roozbeh Roozbeh
BCBenjamín Castañeda
Benjamín Castañeda
Objective . The mechanical behaviour of soft tissue is influenced by its elastic and viscous characteristics. Therefore, the aim of this study was to develop a validated method to characterise the viscoelastic properties of soft tissues based on ultrasound elastography data. Approach . Plantar soft tissue was chosen as the tissue of interest, and gelatine-phantoms replicating its mechanical properties were manufactured for validation of the protocol. Both plantar soft tissue and the phantom were scanned using Reverberant shear wave ultrasound (US) elastography at 400–600 Hz. Shear wave speed was estimated using the US particle velocity data. The viscoelastic parameters were extracted by fitting the Young’s modulus as a function of frequency derived from the constitutive equations of the eight rheological models (four classic and their fractional-derivative versions) to the shear wave dispersion data. Furthermore, stress-time functions derived from the eight rheological models were fitted to the phantom stress-relaxation data. Main results . The viscoelastic parameters estimated using elastography data based on the fractional-derivative (FD) models, compared to the classic models, were closer to those quantified using the mechanical test. In addition, the FD-Maxwell and FD-Kelvin–Voigt models showed to more effectively replicate the viscoelastic behaviour of the plantar soft tissue with minimum number of model parameters ( R 2 = 0.72 for both models) . Hence the FD-KV and FD-Maxwell models can more effectively quantify the viscoelastic characteristics of the soft tissue compared to other models. Significance . In this study, a method for mechanical characterisation of the viscoelastic properties of soft tissue in ultrasound elastography was developed and fully validated. An investigation into the most valid rheological model and its applications in plantar soft tissue assessment were also presented. This proposed approach for the characterisation of viscous and elastic mechanical properties of soft tissue has implications in assessing the soft tissue function where those can be used as markers for diagnosis or prognosis of tissue status.

23 July 2018 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
EGEduardo A. Gonzalez
Eduardo A. Gonzalez
SRStefano E. Romero
Stefano E. Romero
BCBenjamín Castañeda
Benjamín Castañeda
Imaging of musculoskeletal tissue dynamics is currently an exploratory field with the goal of aiding rehabilitation and performance evaluation of pathological or asymptomatic patients. In this pilot study, initial elasticity assessments of the biceps brachii were conducted in a novel crawling wave sonoelastography (CWS) system implemented on a research ultrasound instrument with graphical processing unit capabilities, displaying quantitative elasticity values at 4 frames per second. The CWS system computes the tissue stiffness with the generation of an interference pattern from external vibrators, which can overcome depth limitations of imaging systems with internal excitation sources. Validation on gelatin-based phantoms reported low bias of elasticity values (4.7%) at low excitation frequencies. Preliminary results on in vivo muscle characterization are in accordance with average elasticity values for relaxed and contracted tissues found in the literature, as well as for a range of weight loads.

1 January 2022 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
SRStefano E. Romero
Stefano E. Romero
RNRoozbeh Naemi
Roozbeh Naemi
GFGilmer Flores
Gilmer Flores
DADavid Allan
David Allan
JOJuvenal Ormachea
Juvenal Ormachea
BCBenjamin Castaneda
Benjamin Castaneda

27 January 2017
Verified
Conference Paper
Closed access
PDF file
SRStefano E. Romero
Stefano E. Romero
EGEduardo A. Gonzalez
Eduardo A. Gonzalez
RLRoberto Lavarello
Roberto Lavarello
BCBenjamín Castañeda
Benjamín Castañeda