Tobias Wagner

Tobias Wagner

Auto-generated profile, based on publicly available information

Tobias Wagner

Department of Imaging and Pathology, Division of Medical Physics & Quality Assessment, KU Leuven, Leuven, Belgium

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

11 July 2015
Verified
Conference Paper
Open access
JBJakob Bossek
Jakob Bossek
BBBernd Bischl
Bernd Bischl
TWTobias Wagner
Tobias Wagner
GRGünter Rudolph
Günter Rudolph
The majority of algorithms can be controlled or adjusted by parameters. Their values can substantially affect the algorithms' performance. Since the manual exploration of the parameter space is tedious -- even for few parameters -- several automatic procedures for parameter tuning have been proposed. Recent approaches also take into account some characteristic properties of the problem instances, frequently termed instance features. Our contribution is the proposal of a novel concept for feature-based algorithm parameter tuning, which applies an approximating surrogate model for learning the continuous feature-parameter mapping. To accomplish this, we learn a joint model of the algorithm performance based on both the algorithm parameters and the instance features. The required data is gathered using a recently proposed acquisition function for model refinement in surrogate-based optimization: the profile expected improvement. This function provides an avenue for maximizing the information required for the feature-parameter mapping, i.e., the mapping from instance features to the corresponding optimal algorithm parameters. The approach is validated by applying the tuner to exemplary evolutionary algorithms and problems, for which theoretically grounded or heuristically determined feature-parameter mappings are available.


31 January 2025 in European Radiology
Verified
Journal Article
Open access
PDF file
TWTobias Wagner
Tobias Wagner
LCLesley Cockmartin
Lesley Cockmartin
YWYao-Kuan Wang
Yao-Kuan Wang
NMNicholas Marshall
Nicholas Marshall
HBHilde Bosmans
Hilde Bosmans
Objectives: Investigate the impact of mammography device grouped by vendor on volumetric breast density and propose a method that mitigates biases when determining the proportion of high-density women. Materials and methods: Density grade class and volumetric breast density distributions were obtained from mammographic images from three different vendor devices in different centers using breast density evaluation software in a retrospective study. Density distributions were compared across devices with a Mann–Whitney U test and breast density thresholds corresponding to distribution percentiles calculated. A method of matching density percentiles is proposed to determine women at potentially high risk while mitigating possible bias due to the device used for screening. Results: 2083 (mean age 59 ± 5.4), 531 (mean age 58.8 ± 5.7) and 244 (mean age 60.7 ± 6.0) screened women were evaluated on three vendor devices, respectively. Both the density grade distribution and the volumetric breast density were different between Vendor 1 and Vendor 2 data (p < 0.001) and between Vendor 1 and Vendor 3 data (p < 0.001). Between Vendor 2 and Vendor 3, no significant difference was observed (p = 0.67 for density grade, p = 0.29 for volumetric density). To recruit the top 10% of women with extremely dense breasts required respective density thresholds of 16.1%, 13.6% and 13.8% for the three vendor devices. Conclusion: Density grade class and volumetric breast density distributions differ between devices grouped by vendor and can result in statistically different breast density distributions. Percentile-dependent density thresholds can ensure unbiased selection of high-risk women. Key Points: Question Does the use of x-ray systems from different vendors influence breast density evaluation and the resulting selection of high-risk women during breast cancer screening? Findings Statistically significant differences were observed between breast density distributions of different vendors; a method of matching via percentiles is proposed to prevent biased density evaluations. Clinical relevance Measured breast density distributions differed between X-ray devices. A workaround is proposed that determines density thresholds corresponding to a specified population, allowing the same proportion of women to be selected with a density algorithm. Graphical

20 October 2022 in arXiv
Verified
Preprint
Open access
PDF file
SPSteffen Palutke
Steffen Palutke
MMMichael Martins
Michael Martins
SKStephan Klumpp
Stephan Klumpp
KBKarolin Baev
Karolin Baev
MRMathias Richter
Mathias Richter
KTKai Tiedtke
Kai Tiedtke
The dependency on the excitation energy of ultrafast multi-photon ionization of xenon by intense, short extreme ultraviolet pulses (XUV) was investigated in the vicinity of the 4$d$ 'giant' resonance using ion time-of-flight spectroscopy. The yields of the high charge states of xenon show strong variations with the excitation energy. With reference to simulated absorption spectra, we can link the photon energy dependency to resonance structures of single-electron excitations mainly in the xenon N-shell and purely sequential multi-photon absorption.