João Paulo Vicentini Fracarolli

João Paulo Vicentini Fracarolli

Auto-generated profile, based on publicly available information

João Paulo Vicentini Fracarolli

CPqD Foundation, Campinas, Brazil

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2015
Verified
Conference Paper
Closed access
Joao RosolemJoao Rosolem
Joao Rosolem
ETElias K. Tomiyama
Elias K. Tomiyama
DDDanilo C. Dini
Danilo C. Dini
Fabio BassanFabio Bassan
Fabio Bassan
Rivael PenzeRivael Penze
Rivael Penze
RTRomulo M. Teixeira
Romulo M. Teixeira
In this work, we present the results of a fiber optic powered sensor for monitoring partial discharges on high voltage transformer bushings. The main advantages of the proposed system are high bandwidth, passivity, flexibility, non-intrusive, human and equipment risk free, easy installation and inherently galvanic isolation. The complete system is composed by the sensor that is one active hermetically sealed circular antenna installed near to the bushing flange, a fiber network and a control unit. The sensor is powered only by the optical power provided by one optic fiber connected to a remote optical source. At the same time, the partial discharge signals are transmitted by another optical fiber to the control unit installed in the substation room. We describe the design and the performance evaluation of the fiber optic powered antenna in laboratory.

1 December 2015 in Optical Fiber Technology
Verified
Journal Article
Closed access
Joao RosolemJoao Rosolem
Joao Rosolem
Fabio BassanFabio Bassan
Fabio Bassan
Rivael PenzeRivael Penze
Rivael Penze
ALAriovaldo Antonio Leonardi
Ariovaldo Antonio Leonardi
JFJoão Paulo Vicentini Fracarolli
João Paulo Vicentini Fracarolli
Claudio FloridiaClaudio Floridia
Claudio Floridia

27 May 2019 in Remote Sensing
Verified
Journal Article
Open access
PDF file
Claudio FloridiaClaudio Floridia
Claudio Floridia
Joao RosolemJoao Rosolem
Joao Rosolem
JFJoão Paulo Vicentini Fracarolli
João Paulo Vicentini Fracarolli
Fabio BassanFabio Bassan
Fabio Bassan
Rivael PenzeRivael Penze
Rivael Penze
MRMaria Angélica Carmona da Motta Resende
Maria Angélica Carmona da Motta Resende
A novel system to monitor methane fugitive emissions was developed using passive optical sensors to attend to the natural gas production and transportation industry. The system is based on optical time domain reflectometry and direct optical absorption spectroscopy. The system was tested in a gas compressor station for four months. The system was capable to measure methane concentration at two points showing its correlation with meteorological data, specially wind velocity and local temperature. Methane concentrations varied from 2.5% to 15% in the first monitored point by sensor 1, and from 5% to 30%, in the second point with sensor 2. Both sensors exhibited a moderate negative correlation with wind velocity with a mean Pearson coefficient of −0.61, despite the external cap designed to avoid the influence of wind. Sensor 2 had a modification to its external package that reduced this mean correlation coefficient to −0.30, considered to be weak to negligible. Regarding temperature, a moderate mean correlation of −0.59 was verified for sensor 1 and zero mean correlation was found for sensor 2. Based on these results the system was proven to be robust for installation in gas transportation or processing facilities.

1 October 2018
Verified
Conference Paper
Closed access
SSSender R. Dos Santos
Sender R. Dos Santos
JFJoao P. V. Fracarolli
Joao P. V. Fracarolli
ANAlex Y. M. Narita
Alex Y. M. Narita
JAJuliana C. M. S. Aranha
Juliana C. M. S. Aranha
FMFelipe L. R. Marques
Felipe L. R. Marques
PHPaulo Vitor B. Hamacek
Paulo Vitor B. Hamacek
Passive dissipative balancing requires a lot of heat dissipation and current techniques do not guarantee optimal balance of battery pack energy, requiring a high-cost Battery Management System (BMS) solution which uses resistive components with high power value and fail to detect discrepant cells, possible damaging the BMS balance circuit. In this paper, a new methodology is proposed to perform active dissipative balance of lithium-ion cells with optimized energy management by controlling the source current in order to adjust the recharge rate between the cells in relation to their load level and the detection of discrepant cells based on the voltage values.

1 October 2016
Verified
Conference Paper
Closed access
CFC. Floridia
C. Floridia
FSF. C. Salgado
F. C. Salgado
JRJ. B. Rosolem
J. B. Rosolem
Fabio BassanFabio Bassan
Fabio Bassan
JFJ. P. V. Fracarolli
J. P. V. Fracarolli
LPL. M. Pereira
L. M. Pereira
We demonstrated a novel methane leak detection system that enables the remote detection and identification of fugitive emission of methane in multiple points employing only one optical fiber and using optical time domain reflectometry and optical frequency scanning in the absorption region of the analyzed gas. Multiple passive remote sensors can be analyzed using a single interrogator equipment with a range of tens of kilometers.

12 May 2016
Verified
Conference Paper
Closed access
PDF file
JFJoão P. V. Fracarolli
João P. V. Fracarolli
Joao RosolemJoao Rosolem
Joao Rosolem
ETElias K. Tomiyama
Elias K. Tomiyama
CFClaudio Floridia
Claudio Floridia
Rivael PenzeRivael Penze
Rivael Penze
FFFabiano Fruett
Fabiano Fruett