Bruna Ferri Serafini

Bruna Ferri Serafini

Auto-generated profile, based on publicly available information

Bruna Ferri Serafini

Biosens Development and Industry of Biosensors LTDA (BIOSENS)

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2026 in ACS Omega
Verified
Journal Article
Open access
GJGabriela Victória de Mello Jantzch
Gabriela Victória de Mello Jantzch
RBRodrigo Ritzel Bernasconi
Rodrigo Ritzel Bernasconi
MSMilleny Germann Souza
Milleny Germann Souza
DMDuane da Silva Moraes
Duane da Silva Moraes
BSBruna Ferri Serafini
Bruna Ferri Serafini
RXRicardo Machado Xavier
Ricardo Machado Xavier
Antiphospholipid syndrome (APS) is an autoimmune disorder associated with antiphospholipid antibodies, leading to coagulation imbalance, thrombosis, and obstetric complications. It may occur as a primary condition or in association with systemic lupus erythematosus (SLE). Patients with APS often require long-term anticoagulation therapy, monitored by prothrombin time (PT) expressed as international normalized ratio (INR). Remote laboratory testing (RLT) devices may improve monitoring by providing faster and more convenient results; however, their accuracy in APS patients remains uncertain. This study aimed to validate a rapid and portable device (bSens.INR) for PT/INR measurement in patients with APS and SLE receiving warfarin, compared to a control group without these conditions. Accuracy, repeatability, and agreement with the standard laboratory method were evaluated according to established guidelines. A total of 40 PT/INR measurements were obtained using the bSens.INR and 20 using the standard method. Overall concordance was 77.5%, with lower agreement in APS/SLE patients (60%) compared to controls (95%). Approved results showed 100% repeatability. A strong positive correlation was observed between methods (Spearman r = 0.80, p < 0.0001), while Bland–Altman analysis indicated a bias of 0.26 INR units. The presence of antiphospholipid antibodies appears to interfere with PT/INR measurements obtained by the bSens.INR, reducing accuracy in APS and SLE patients. Although the device shows promising performance, its use in autoimmune populations should be approached with caution, reinforcing previous findings on the limitations of RLT in these conditions.

27 October 2026 in ACS Omega
Verified
Journal Article
Open access
DMDuane da Silva Moraes
Duane da Silva Moraes
BSBruna Ferri Serafini
Bruna Ferri Serafini
FKFelipe Longaray Kadel
Felipe Longaray Kadel
GJGabriela VictórIa de Mello Jantzch
Gabriela VictórIa de Mello Jantzch
MSMilleny Germann Souza
Milleny Germann Souza
JMJulia Konzen Moreira
Julia Konzen Moreira
Syphilis remains a major public health concern. Although non-treponemal tests are widely used for screening and treatment monitoring, their interpretation relies on visual assessment of flocculation. Here, an amperometric biosensor using isolated cardiolipin (0.03–0.12%) as the sole biorecognition element was developed on carbon/graphene screen-printed electrodes. The 0.06% concentration was selected for subsequent experiments, and the biosensor discriminated positive and negative control materials across two electrode batches. Progressive positive-control dilution produced a systematic electrochemical response (R2 = 0.921). Electrode functionalization significantly affected the response (p < 0.001), supporting the contribution of immobilized cardiolipin. Discrimination was maintained under physiological and pathological glucose conditions (adjusted p < 0.001). These findings provide a preliminary proof-of-concept for cardiolipin-based electrochemical assessment of non-treponemal antibody reactivity. Further studies using clinical samples are required to establish analytical and clinical performance and investigate semiquantitative evaluation by correlating electrochemical responses with defined serological titers.

27 October 2026 in Practical Laboratory Medicine
Verified
Journal Article
Open access
JMJulia Konzen Moreira
Julia Konzen Moreira
GJGabriela Victória de Mello Jantzch
Gabriela Victória de Mello Jantzch
DMDuane da Silva Moraes
Duane da Silva Moraes
BSBruna Ferri Serafini
Bruna Ferri Serafini
MSMilleny Germann Souza
Milleny Germann Souza
WHWillyan Hasenkamp
Willyan Hasenkamp