28 September 2011 in Radiation Protection Dosimetry
SWS. S. Hakmana Witharana
The design, simulation results and measurements of a new neutron energy spectrometer are presented. The device, which may be called NNS, for Nested Neutron Spectrometer, works under the same principles as a Bonner Sphere Spectrometer (BSS) System, i.e. whereby a thermal neutron detector is surrounded by a polyethylene moderator. However, the moderator is cylindrical in shape. The different thicknesses of moderator are created by inserting one cylinder into another, much like nested Russian dolls. This design results in a much lighter instrument that is also easier to use in the field. Simulations and measurements show that, despite its shape, the device can be made to offer a near angular isotropic response to neutrons and that unfolded neutron spectra are in agreement with those obtained with a more traditional BSS.
1 June 2016 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
This work compares GEANT4 with MCNPX in the characterization of a boron-lined neutron detector. The neutron energy ranges simulated in this work (0.025eV to 20MeV) are the traditional domain of MCNP simulations. This paper addresses the question, how well can GEANT4 and MCNPX be employed for detailed thermal neutron detector characterization? To answer this, GEANT4 and MCNPX have been employed to simulate detector response to a 252Cf energy spectrum point source, as well as to simulate mono-energetic parallel beam source geometries. The 252Cf energy spectrum simulation results demonstrate agreement in detector count rate within 3% between the two packages, with the MCNPX results being generally closer to experiment than are those from GEANT4. The mono-energetic source simulations demonstrate agreement in detector response within 5% between the two packages for all neutron energies, and within 1% for neutron energies between 100eV and 5MeV. Cross-checks between the two types of simulations using ISO-8529 252Cf energy bins demonstrates that MCNPX results are more self-consistent than are GEANT4 results, by 3–4%
1 May 2015 in Applied Radiation and Isotopes
SWSampath Hakmana Witharana
Sampath Hakmana Witharana
1 October 2007 in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
15 December 2020 in Radiation Protection Dosimetry
Gamma-ray spectra were measured using a LaBr$_{3}$(Ce) spectrometer during the outage periods, aiming at quantifying the gamma source term of radiation workers’ exposure, at the CANDU nuclear power reactors, for the purposes of eye lens dosimetry. The spectra were measured inside the boiler rooms, of the Bruce Power and Ontario Power Generation (OPG) CANDU nuclear power plants, where workers are exposed to relatively high dose rates radiation fields during the maintenance work. Prior to measurements at the CANDU reactors, the pulse shaping parameters of the gamma spectrometer were optimised for high rates gamma fields, up to an input rates of 120 kcps, in order to accomplish a high output rate with a reasonable energy resolution. In parallel, the response of the LaBr$_{3}$(Ce) detector was characterized by experiments and Monte Carlo simulations. The gamma spectra measured at the CANDU reactors were reported in terms of the gamma-ray fluence rate spectrum. In all measured data, $^{60}$Co and $^{95}$Nb were main contributors of the gamma fields. The measured spectra have been used to calculate the dosimetric quantities of interest: personal dose equivalents H$_{p}$(10) and H$_{p}$(0.07) and eye lens absorbed dose.
16 January 2014 in Radiation Protection Dosimetry
Monte Carlo simulations were performed to evaluate dose for possible treatment of cancers by boron neutron capture therapy (BNCT). The computational model of male Oak Ridge National Laboratory (ORNL) phantom was used to simulate tumours in the lung. Calculations have been performed by means of the MCNP5/X code. In this simulation, two opposite neutron beams were considered, in order to obtain uniform neutron flux distribution inside the lung. The obtained results indicate that the lung cancer could be treated by BNCT under the assumptions of calculations.