11 March 2024 in Nature Neuroscience
10 July 2025 in Nature Photonics
Stimulated Brillouin scattering microscopy enables all-optical, non-contact, high-spatial-resolution mechanical imaging with high specificity. Recent advances in quasi-continuous-wave stimulated Brillouin scattering have substantially reduced the required laser power. However, the pixel dwell time remains limited to 20 ms, and further reductions without compromising resolution, precision or specificity are challenging. Here we address this limitation by developing a frequency-doubled pulsed fibre laser system operating at 780 nm, delivering a peak power of 267 W. To mitigate the high-intensity noise intrinsic to amplified fibre lasers, we implement a high-performance noise cancellation system based on auto-balanced detection. As a result, we achieve a pixel dwell time as short as 200 µs for full spectral acquisition, which is two orders of magnitude faster than previous stimulated Brillouin scattering implementations, and maintain an average power of 30 mW. We demonstrate high-speed, high-specificity and high-sensitivity Brillouin imaging of live single cells, organoids, zebrafish larvae and ovarian follicles with subcellular details. Furthermore, we capture the in vivo biomechanical dynamics of rapid cell divisions during the early embryo development of Caenorhabditis elegans in a living worm.
1 May 2019 in OncoTargets and Therapy
Background: Oral squamous cell carcinoma (OSCC) is the most frequent oral malignancy in humans. Increasing numbers of studies suggest that circular RNAs (circRNAs) play a major role in tumorigenesis and tumor progression. Purpose: We aimed to identify differently expressed circRNA in OSCC and adjacent normal tissue. As well as to study the correlation of circRNA expression with clinicopathological feature in patients with OSCC. Patients and methods: Primary OSCC tissues and adjacent normal tissues from twenty-seven OSCC patients were collected. The expression level of hsa_circ_009755 were analyzed by qRT-PCR. Results: The measurement results from qRT-PCR revealed that hsa_circ_009755 expression was low in OSCC tissue samples and cell lines, and the low expression of hsa_circ_009755 was closely related to a clinicopathological feature in patients with OSCC. Moreover, the area under the receiver operating characteristic curve was 0.782, which indicates the sensitivity and specificity of the diagnostic value. Conclusion: Our data indicates that hsa_circ_009755 could serve as a potential biomarker for OSCC diagnosis.