Pauzi Abdullah

Pauzi Abdullah

Auto-generated profile, based on publicly available information

Pauzi Abdullah

School of Chemical Sciences and Food Technology, Faculty of Science and Technology, Universiti Kebangsaan Malaysia (UKM), 43600 Bangi, Selangor, Malaysia; Centre for Water Research and Analysis (ALIR), Faculty of Science and Technology, Universiti Kebangsaan Malaysia (UKM), 43600 Bangi, Selangor, Malaysia

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 April 2013 in BMC Chemistry
Verified
Journal Article
Open access
PDF file
NSNaghmeh Saadati
Naghmeh Saadati
PAPauzi Abdullah
Pauzi Abdullah
ZZZuriati Zakaria
Zuriati Zakaria
NPNooshin Peyman
Nooshin Peyman
MRMajid Rezayi
Majid Rezayi
HHHoushang Hassonizadeh
Houshang Hassonizadeh
Background: Reliable values for method validity of organochlorine pesticides determination were investigated, in water by solid phase extraction and in sediment by Soxhlet extraction, followed by gas chromatography equipped with an electron capture detector. Organochlorine pesticides are categorized as Persistent Organic Pollutants. Hence, critical decisions to control exposure to these chemicals in the environment are based on their levels in different media; it is important to find valid qualitative and quantitative results for these components. In analytical chemistry, internal quality procedures are applied to produce valid logical results. Result: In this study, 18 organochlorine pesticides were targeted for analysis and determination in water and river sediment. Experiments based on signal-to-noise ratio, calibration curve slope and laboratory fortified blank methods were conducted to determine the limits of qualification and quantification. The data were compared with each other. The limitation values, following Laboratory Fortified Blank, showed significant differences in the signal-to-noise ratio and calibration curve slope methods, which are assumed in the results for the sample concentration factor to be 1,000 times in water and 10 times in sediment matrices. The method detection limit values were found to be between 0.001 and 0.005 μg/L (mean of 0.002 ± 0.001) and 0.001 and 0.005 μg/g (mean of 0.001 ± 0.001). The quantification limits were found to be between 0.002 and 0.016 μg/L (mean of 0.006 ± 0.004) and 0.003 and 0.017 μg/g (mean of 0.005 ± 0.003 μg/L) for water and sediment, respectively, based on the laboratory fortified blank method. Because of different slopes in the calibration methods, it was also found that the limitation values for some components from the internal standard were higher than from external standard calibration, because in the latter a factor for injection efficiency is applied for calibration. Conclusion: Technically, there are differentiations between detection limits for quality and quantity from component to component, resulting from noise, response factors of instruments and matrix interference. However, the calculation method is the cause of differentiation for each component of the different methods. The results show that for no matter what component, the relationship between these levels in different methods is approximately: Signal to Noise : Calibration Slope = 1:10. Therefore, due to different methods to determine LOD and LOQ, the values will be different. In the current study, laboratory fortified blank is the best method, with lower limitation values for Soxhlet and solid phase extraction of OCPs from sediment and water, respectively.


1 December 2015 in Journal of Hazardous Materials
Verified
Journal Article
Closed access
FAFouad Al-Qaim
Fouad Al-Qaim
ZMZainab H. Mussa
Zainab H. Mussa
MOMohamed R. Othman
Mohamed R. Othman
PAP. Abdullah
P. Abdullah

7 November 2012 in BMC Chemistry
Verified
Journal Article
Open access
PDF file
NSNaghmeh Saadati
Naghmeh Saadati
PAPauzi Abdullah
Pauzi Abdullah
ZZZuriati Zakaria
Zuriati Zakaria
MRMajid Rezayi
Majid Rezayi
NHNader Hosseinizare
Nader Hosseinizare
The serious impact effects of persistent organic pollutants such as organochlorine pesticides, especially dichlorodiphenyltrichloroethane family (DDTs) and hexachlorocyclohexane isomers (HCHs) have been causing widespread concern, despite effective control on their manufacturing, agricultural and vector practices. In that, in addition to the previous global limitations on DDTs usage, α-HCH, β-HCH and lindane have also became an on-going topic of global relevance based on the latest Stockholm Convention list on 10th of May 2009. Concentrations of dichlorodiphenyltrichloroethane family (DDTs) and hexachlorocyclohexane isomers (HCHs) were determined by GC-ECD in Cameron Highlands, the main vegetables and flowers farming area in Malaysia as an agricultural tropical environment. A total of 112 surface water and sediment samples at eight points were collected along the main rivers in the area namely Telom and Bertam in the dry and wet seasons of 2011.

29 March 2009 in Chromatographia
Verified
Journal Article
Closed access
PDF file
WSWaseem Sadia
Waseem Sadia
APAbdullah Pauzi
Abdullah Pauzi

28 August 2013 in Tropical Journal of Pharmaceutical Research
Verified
Journal Article
Open access
PDF file
FAFouad Al-Qaim
Fouad Al-Qaim
PAP Abdullah
P Abdullah
MOMohamed Othman
Mohamed Othman
JLJ Latip
J Latip
WAWm Afiq
Wm Afiq
Purpose: To develop and validate a simple method using solid – phase extraction along with liquid chromatography–time of flight mass spectrometry for the analysis of pharmaceuticals in surface water of Tangkas River, Malaysia. Methods: Liquid chromatography (LC) was performed on a Dionex Ultimate 3000/LC 09115047 (USA) system equipped with a vacuum degasser, a quaternary pump, an autosampler and UV-Vis diod array detector. Chromatography was performed on a Thermo Scientific C18 (250 mm x 2.1 mm, i.d.: 5μm) column. The injection volume was 20 μL. All compounds (hydrochlorothiazide, gliclazide, diclofenac-Na and mefenamic acid) were analysed in negative ion (NI) mode and eluted off the column with a mobile phase consisting of (A) 0.1% formic acid (FA) in deionised water (DIW) and (B) 40% acetonitrile (ACN) in methanol (MeOH) at 0.3 ml/min. Mass spectrometry was performed on a time of flight (TOF) instrument. Results: The linearity range, 5 - 500 ng/mL, provided a determination coefficient (R2) > 0.99 for all compounds. The limit of detection (LOD) ranged from 65 - 136 ng/L while recovery ranged from 45 - 111.2 % in the river water. Two pharmaceutical compounds were detected in the surface water samples: diclofenac sodium and mefenamic acid at concentrations of 340 and 545 ng/L, respectively. Conclusion: The developed method is linear in the range 5 - 500 ng/mL, and precise and acceptable recoveries were obtained. In addition, this method is suitable to identify and quantify trace concentrations of diclofenac sodium and mefenamic acid in surface water. Keywords: Diclofenac, Mefenamic acid, Electrospray Ionization, Mass spectrometry, Solid phase extraction (SPE), Tangkas river, Collision energy.