13 November 2018 in RSC Advances
Environmentally friendly probe materials for detecting copper ions were studied in this research. Fluorescent emission of quercetin (Q) was observed in the buffer solution (pH = 7.40), and (2-hydroxypropyl)-β-cyclodextrin (CD) could enhance the fluorescence intensity of Q. The UV/Vis spectrum showed that the Q-CD system was formed. After adding copper ions into the Q-CD system, the fluorescent emission intensity of Q-CD system generated quenching, and other metal ions could not bring change, which meant the Q-CD system showed good selectivity to copper ions. The fluorescence titration spectra showed that the concentration of copper ions was inversely proportional to fluorescence intensity, and gave a good linear change in fluorescence emission intensity in response to the concentration of copper ions ranging from 5.0 × 10−8 to 8.3 × 10−6 mol L−1. The calibration curve of the relationship between the intensity and copper ions concentration was y = −9.24x + 844.51 (R2 = 0.997). The detection limit of copper ions was measured to be 2.3 × 10−8 mol L−1. The probable mechanism was studied by UV/Vis spectrum and Job's plot method. The results indicated that Q-CD-Cu(II) complex was formed and intramolecular charge transfer (ICT) took place. At last, the probe was successfully applied for determination of copper ions in water bodies, vegetables and fruits with good recovery. The study showed that Q-CD system could detect copper ions as a fluorescent probe with high selectivity, sensitivity and larger linearity range.
1 November 2016 in Sensors and Actuators B: Chemical
1 January 2021 in JBIC Journal of Biological Inorganic Chemistry
1 October 2007 in Journal of Pediatric Hematology/Oncology
Objectives The aim of this study was to observe the morbidity of elimination delay in Chinese children with acute lymphoblastic leukemia during high-dose methotrexate (HDMTX) therapy and the toxicities. Patients and Methods A total of 121 children with acute lymphoblastic leukemia on HDMTX therapy were enrolled into this study. Patients were divided into groups on the basis of either dosage (3 g/m2 vs. 5 g/m2) or infusion duration (7 h vs. 24 h). CF/MTX index was used to determine the calcium folinate (CF) rescuing intensity and toxicity was evaluated according to World Health Organization criteria. Results The overall morbidity of elimination delay was 12.1% in a total of 497 infusions. Patients with elimination delay had lower platelet count (P<0.01) and greater cumulative CF rescuing intensity (P<0.001). In 3-g group, children with elimination delay experienced severer oral mucous membrane damage (P0.05) or 7 and 24-hour infusion groups (P>0.05). The only raised adverse effect in 5-g group was gastrointestinal (P=0.003) as compared with 3-g group. The CF rescuing intensity of 5-g group without elimination delay was lower than that of the 3-g group (P<0.01). Conclusions (1) HDMTX with 5 g/m2 is as safe as 3 g/m2 under adequate hydration and alkalization. Twenty-four–hour infusion is optimal. (2) Individualized dosing is necessary.
8 December 2004 in The Journal of Chemical Physics
A general formulation of nonperturbative quantum dynamics of solutes in a condensed phase is proposed to calculate linear and nonlinear vibrational line shapes. In the weak solute-solvent interaction limit, the temporal absorption profile can be approximately factorized into the population relaxation profile from the off-diagonal coupling and the pure-dephasing profile from the diagonal coupling. The strength of dissipation and the anharmonicity-induced dephasing rate are derived in Appendix A. The vibrational energy relaxation (VER) rate is negligible for slow solvent fluctuations, yet it does not justify the Markovian treatment of off-diagonal contributions to vibrational line shapes. Non-Markovian VER effects are manifested as asymmetric envelops in the temporal absorption profile, or equivalently as side bands in the frequency domain absorption spectrum. The side bands are solvent-induced multiple-photon effects which are absent in the Markovian VER treatment. Exact path integral calculations yield non-Lorentzian central peaks in absorption spectrum resulting from couplings between population relaxations of different vibrational states. These predictions cannot be reproduced by the perturbative or the Markovian approximations. For anharmonic potentials, the absorption spectrum shows asymmetric central peaks and the asymmetry increases with anharmonicity. At large anharmonicities, all the approximation schemes break down and a full nonperturbative path integral calculation that explicitly accounts for the exact VER effects is needed. A numerical analysis of the O-H stretch of HOD in D(2)O solvent reveals that the non-Markovian VER effects generate a small recurrence of the echo peak shift around 200 fs, which cannot be reproduced with a Markovian VER rate. In general, the nonperturbative and non-Markovian VER contributions have a stronger effect on nonlinear vibrational line shapes than on linear absorption.