Kristian König

Kristian König

Auto-generated profile, based on publicly available information

Kristian König

Technische Universität Darmstadt

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 October 2021 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
SPSkyy V. Pineda
Skyy V. Pineda
KKKristian König
Kristian König
DRDominic M. Rossi
Dominic M. Rossi
BBB. Alex Brown
B. Alex Brown
AIAnthony Incorvati
Anthony Incorvati
FSFelix Sommer
Felix Sommer
The nuclear root-mean-square charge radius of Ni54 was determined with collinear laser spectroscopy to be R(Ni54)=3.737(3)  fm. In conjunction with the known radius of the mirror nucleus Fe54, the difference of the charge radii was extracted as ΔRch=0.049(4)  fm. Based on the correlation between ΔRch and the slope of the symmetry energy at nuclear saturation density (L), we deduced 21≤L≤88  MeV. The present result is consistent with the L from the binary neutron star merger GW170817, favoring a soft neutron matter EOS, and barely consistent with the PREX-2 result within 1σ error bands. Our result indicates the neutron-skin thickness of Ca48 as 0.15–0.21 fm.

23 September 2022 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
FSFelix Sommer
Felix Sommer
KKKristian König
Kristian König
DRDominic M. Rossi
Dominic M. Rossi
NENathan Everett
Nathan Everett
DGDavid Garand
David Garand
ATAndrea Teigelhöfer
Andrea Teigelhöfer
Nuclear charge radii of Ni55,56 were measured by collinear laser spectroscopy. The obtained information completes the behavior of the charge radii at the shell closure of the doubly magic nucleus Ni56. The trend of charge radii across the shell closures in calcium and nickel is surprisingly similar despite the fact that the Ni56 core is supposed to be much softer than the Ca48 core. The very low magnetic moment μ(Ni55)=−1.108(20)  μN indicates the impact of M1 excitations between spin-orbit partners across the N,Z=28 shell gaps. Our charge-radii results are compared to ab initio and nuclear density functional theory calculations, showing good agreement within theoretical uncertainties.

16 April 2024 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
KKKristian König
Kristian König
JBJulian C. Berengut
Julian C. Berengut
ABAnastasia Borschevsky
Anastasia Borschevsky
ABAlex Brinson
Alex Brinson
ABAlex Brown
Alex Brown
AZAndrei Zaitsevskii
Andrei Zaitsevskii
The nuclear charge radius of Si32 was determined using collinear laser spectroscopy. The experimental result was confronted with ab initio nuclear lattice effective field theory, valence-space in-medium similarity renormalization group, and mean field calculations, highlighting important achievements and challenges of modern many-body methods. The charge radius of Si32 completes the radii of the mirror pair Ar32−Si32, whose difference was correlated to the slope L of the symmetry energy in the nuclear equation of state. Our result suggests L≤60  MeV, which agrees with complementary observables.

25 January 2021 in Physical Review C
Verified
Journal Article
Open access
PDF file
HHH. Heylen
H. Heylen
CDC. S. Devlin
C. S. Devlin
WGW. Gins
W. Gins
MBM. L. Bissell
M. L. Bissell
KBK. Blaum
K. Blaum
DYD. T. Yordanov
D. T. Yordanov
Hyperfine spectra of Al27–32 (Z=13) have been measured at the ISOLDE-CERN facility via collinear laser spectroscopy using the 3s23p2P3/2o→3s24s2S1/2 atomic transition. For the first time, mean-square charge radii of radioactive aluminum isotopes have been determined alongside the previously unknown magnetic dipole moment of Al29 and electric quadrupole moments of Al29,30. A potentially reduced charge radius at N=19 may suggest an effect of the N=20 shell closure, which is visible in the Al chain, contrary to other isotopic chains in the sd shell. The experimental results are compared with theoretical calculations in the framework of the valence-space in-medium similarity renormalization group using multiple sets of two- and three-nucleon forces from chiral effective field theory. While the trend of experimental magnetic dipole and electric quadrupole moments is well reproduced, the absolute values are underestimated by theory, which is consistent with earlier studies. Moreover, both the scale and trend of the charge radii appear to be very sensitive to the chosen interaction.

5 September 2023 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
KKKristian König
Kristian König
SFStephan Fritzsche
Stephan Fritzsche
GHGaute Hagen
Gaute Hagen
JHJason D. Holt
Jason D. Holt
AKAndrew Klose
Andrew Klose
PRPaul-Gerhard Reinhard
Paul-Gerhard Reinhard
Charge radii of neutron deficient Sc40 and Sc41 nuclei were determined using collinear laser spectroscopy. With the new data, the chain of Sc charge radii extends below the neutron magic number N=20 and shows a pronounced kink, generally taken as a signature of a shell closure, but one notably absent in the neighboring Ca, K, and Ar isotopic chains. Theoretical models that explain the trend at N=20 for the Ca isotopes cannot reproduce this puzzling behavior.

21 April 2020 in Applied Physics B
Verified
Journal Article
Open access
PDF file
KKKristian König
Kristian König
PIPhillip Imgram
Phillip Imgram
JKJörg Krämer
Jörg Krämer
BMBernhard Maaß
Bernhard Maaß
KMKonstantin Mohr
Konstantin Mohr
WNWilfried Nörtershäuser
Wilfried Nörtershäuser
Wavelength meters are widely used for frequency determinations and stabilization purposes since they cover a large wavelength range, provide a high read-out rate and have specified accuracies of up to $$10^{-8}$$10-8 . More accurate optical frequency measurements can be achieved with frequency combs but only at the price of considerably higher costs and complexity. In the context of precise and accurate frequency determinations for high-resolution laser spectroscopy, the performance of five different wavelength meters was quantified with respect to a frequency comb. The relative precision as well as the absolute accuracy has been investigated in detail, allowing us to give a sophisticated uncertainty margin for the individual instruments. We encountered a prominent substructure on the deviation between both device types with an amplitude of a few MHz that is repeating on the GHz scale. This finally limits the precision of laser scans which are monitored and controlled with wavelength meters. While quantifying its uncertainty margins, we found a high temporal stability in the characteristics of the wavelength meters which enables the preparation of wavelength-dependent adjustment curves for wide- and short-ranged scans. With this method, the absolute accuracy of wavelength meters can be raised up to the MHz level independently from the wavelength of the reference laser used for calibrating the device. Since this technique can be universally applied, it can lead to benefits in all fields of wavelength meter applications.