29 October 2021 in Physical Review Letters
The nuclear root-mean-square charge radius of was determined with collinear laser spectroscopy to be . In conjunction with the known radius of the mirror nucleus , the difference of the charge radii was extracted as . Based on the correlation between and the slope of the symmetry energy at nuclear saturation density (), we deduced . The present result is consistent with the from the binary neutron star merger GW170817, favoring a soft neutron matter EOS, and barely consistent with the PREX-2 result within error bands. Our result indicates the neutron-skin thickness of as 0.15–0.21 fm.
23 September 2022 in Physical Review Letters
Nuclear charge radii of were measured by collinear laser spectroscopy. The obtained information completes the behavior of the charge radii at the shell closure of the doubly magic nucleus . The trend of charge radii across the shell closures in calcium and nickel is surprisingly similar despite the fact that the core is supposed to be much softer than the core. The very low magnetic moment indicates the impact of excitations between spin-orbit partners across the shell gaps. Our charge-radii results are compared to ab initio and nuclear density functional theory calculations, showing good agreement within theoretical uncertainties.
16 April 2024 in Physical Review Letters
The nuclear charge radius of was determined using collinear laser spectroscopy. The experimental result was confronted with ab initio nuclear lattice effective field theory, valence-space in-medium similarity renormalization group, and mean field calculations, highlighting important achievements and challenges of modern many-body methods. The charge radius of completes the radii of the mirror pair , whose difference was correlated to the slope of the symmetry energy in the nuclear equation of state. Our result suggests , which agrees with complementary observables.
25 January 2021 in Physical Review C
Hyperfine spectra of () have been measured at the ISOLDE-CERN facility via collinear laser spectroscopy using the atomic transition. For the first time, mean-square charge radii of radioactive aluminum isotopes have been determined alongside the previously unknown magnetic dipole moment of and electric quadrupole moments of . A potentially reduced charge radius at may suggest an effect of the shell closure, which is visible in the Al chain, contrary to other isotopic chains in the shell. The experimental results are compared with theoretical calculations in the framework of the valence-space in-medium similarity renormalization group using multiple sets of two- and three-nucleon forces from chiral effective field theory. While the trend of experimental magnetic dipole and electric quadrupole moments is well reproduced, the absolute values are underestimated by theory, which is consistent with earlier studies. Moreover, both the scale and trend of the charge radii appear to be very sensitive to the chosen interaction.
5 September 2023 in Physical Review Letters
Charge radii of neutron deficient and nuclei were determined using collinear laser spectroscopy. With the new data, the chain of Sc charge radii extends below the neutron magic number and shows a pronounced kink, generally taken as a signature of a shell closure, but one notably absent in the neighboring Ca, K, and Ar isotopic chains. Theoretical models that explain the trend at for the Ca isotopes cannot reproduce this puzzling behavior.
21 April 2020 in Applied Physics B
Wavelength meters are widely used for frequency determinations and stabilization purposes since they cover a large wavelength range, provide a high read-out rate and have specified accuracies of up to $$10^{-8}$$ . More accurate optical frequency measurements can be achieved with frequency combs but only at the price of considerably higher costs and complexity. In the context of precise and accurate frequency determinations for high-resolution laser spectroscopy, the performance of five different wavelength meters was quantified with respect to a frequency comb. The relative precision as well as the absolute accuracy has been investigated in detail, allowing us to give a sophisticated uncertainty margin for the individual instruments. We encountered a prominent substructure on the deviation between both device types with an amplitude of a few MHz that is repeating on the GHz scale. This finally limits the precision of laser scans which are monitored and controlled with wavelength meters. While quantifying its uncertainty margins, we found a high temporal stability in the characteristics of the wavelength meters which enables the preparation of wavelength-dependent adjustment curves for wide- and short-ranged scans. With this method, the absolute accuracy of wavelength meters can be raised up to the MHz level independently from the wavelength of the reference laser used for calibrating the device. Since this technique can be universally applied, it can lead to benefits in all fields of wavelength meter applications.