Working Group on Balloon Atrial Septostomy Catheter, Japanese Society of Congenital Interventional Cardiology; Department of Pediatric Cardiology, Iwate Medical University, Iwate, Japan
Auto-generated profile, based on publicly available information
Shin Takahashi
Working Group on Balloon Atrial Septostomy Catheter, Japanese Society of Congenital Interventional Cardiology; Department of Pediatric Cardiology, Iwate Medical University, Iwate, Japan
Objective: To compare left ventricular (LV) and right ventricular (RV) volume, function, and image quality of a respiratory-triggered two-dimensional (2D)-cine k-adaptive-t-autocalibrating reconstruction for Cartesian sampling (2D kat-ARC) with those of the standard reference, namely, breath-hold 2D balanced steady-state free precession (2D SSFP), in patients with repaired tetralogy of Fallot (TOF). Methods: 30 patients (14 males, mean age 32.2 ± 13.9 years) underwent cardiac magnetic resonance, and 2D kat-ARC and 2D SSFP images were acquired on short-axis view. Biventricular end-diastolic volume (EDV) and end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), and LV mass (LVM) were analysed. Results: The 2D kat-ARC had significantly shorter scan time (35.2 ± 9.1 s vs 80.4 ± 16.7 s; p < 0.0001). Despite an analysis of image quality showed significant impairment using 2D kat-ARC compared to 2D SSFP cine (p < 0.0001), the two sequences demonstrated no significant difference in terms of biventricular EDV, LVESV, LVSV, LVEF, and LVM. However, the RVESV was overestimated for 2D kat-ARC compared with that for 2D SSFP (73.8 ± 43.2 ml vs 70.3 ± 44.5 ml, p = 0.0002) and the RVSV and RVEF were underestimated (RVSV = 46.2±20.5 ml vs 49.4 ± 20.4 ml, p = 0.0024; RVEF = 40.2±12.7% vs. 43.5±14.0%, p = 0.0002). Conclusion: Respiratory-triggered 2D kat-ARC cine is a reliable technique that could be used in the evaluation of LV volumes and function. Advances in knowledge: 2D cine kat-ARC is a reliable technique for the assessment LV volume and function in patients with repaired TOF.
The case of a patient in whom hemodynamic and electrocardiographic studies using the occlusion test for coronary artery fistulas (CAF) were safely performed prior to catheter embolization is reported. A 1-year-old girl had a separate right coronary artery arising from a left single coronary artery that formed a significant coronary artery fistula to the right ventricle. Coronary steal by the large coronary artery fistula narrowed the left coronary artery. The right coronary artery branches could not be clearly identified due to an overlap with the fistula. Due to the long porous CAF, embolic procedures could cause serious complications. We confirmed the safety by performing an occlusion test of the CAF’s proximal blood vessels. Following total occlusion of the CAF for 10 minutes, pulmonary arterial pressure and aortic blood pressure were not significantly changed. No bradycardia, atrioventricular block, or ST changes were observed. Coil embolization treatment was performed safely. For patients with long distal CAF complicated with a single coronary artery, myocardial ischemia and conduction system disorders can be identified by performing the occlusion test before embolization.