Tae-Hoon Lee

Tae-Hoon Lee

Auto-generated profile, based on publicly available information

Tae-Hoon Lee

Inha University, Incheon, Incheon, Korea (the Republic of)

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 December 2018 in Smart Materials and Structures
Verified
Journal Article
Closed access
PDF file
TLTae-Hoon Lee
Tae-Hoon Lee
Seung-Bok ChoiSeung-Bok Choi
Seung-Bok Choi
Most recently, a novel concept of tunable magneto-rheological (MR) dampers has been proposed which can be operated by only permanent magnet (PM) movement instead of an electromagnetic coil. The damping force variation of the PM based MR damper (PMMR damper) is realized by the variation of the magnetization area or magnet flux dispersion, not by the magnitude of the input current. Thus, the input variable of PMMR damper is totally different from conventional MR damper (CMR damper). In this work, in order to evaluate the feasibility of PMMR damper on real field applications, the investigation on the response time of PMMR damper is empirically undertaken by considering several factors such as magnetic material which can influence on the response time. In order to achieve this goal, PMMR damper is modified to realize damping force variation, and CMR damper whose size is similar to PMMR damper is manufactured for the reasonable comparison. Experimental tests to measure the response time of the dampers are undertaken by considering three influence factors; materials of the magnetic circuit, the magnitude of damping force variation, and the excited frequency of the piston. Then, it is shown that the response time of PMMR damper can be shortened faster than CMR damper.

10 December 2020 in Smart Materials and Structures
Verified
Journal Article
Closed access
PDF file
TLTae-Hoon Lee
Tae-Hoon Lee
BKByung-Hyuk Kang
Byung-Hyuk Kang
GKGi Woo Kim
Gi Woo Kim
Seung-Bok ChoiSeung-Bok Choi
Seung-Bok Choi
A magnetorheological (MR) damper is popularly applied for vibration control owing to its fast response and the easy controllability of the field-dependent damping force. However, most of the existing MR dampers developed so far possess design complexity and a high manufacturing cost due to complicated coil structures. To resolve these drawbacks of the existing MR dampers, a novel magnetic circuit positioned separately from the piston head of MR damper with a simple structure is proposed in this work. As a first step, a design configuration using the operating principle of the magnetic circuit is demonstrated, and subsequently, the magnetic analysis of MR damper is carried out through an analytical approach and the finite element method. In the magnetic analysis, the magnetic flux density is numerically calculated at various piston locations with different applied currents. After determining the principal design parameters of the proposed MR damper, experimental validation to demonstrate the concept of the new magnetic circuit is performed. The effect of the piston stroke length on the damping force is evaluated as a function of the current. In addition, it is discussed that the proposed MR damper can provide much higher control range of the damping force than conventional types of MR dampers in a low level of damping force.

19 February 2019 in Journal of Intelligent Material Systems and Structures
Verified
Journal Article
Closed access
PDF file
TLTae-Hoon Lee
Tae-Hoon Lee
SSSang-Un Shin
Sang-Un Shin
SCSeung-Woo Cha
Seung-Woo Cha
Seung-Bok ChoiSeung-Bok Choi
Seung-Bok Choi
This work presents a new concept of fine position control of vehicle lift systems used for maintenance services, to facilitate specialized tasks such as height balancing of tilted vehicles. The research goal is accomplished by utilizing a controllable hydraulic circuit associated with magnetorheological valves. After establishing the required dynamic forces and position control range of the vehicle’s lift system, a two-coil type of magnetorheological valve is designed with consideration of the field-dependent properties of the magnetorheological fluid and the magnetic flux intensity, which is analyzed using the finite element method. Magnetorheological valves are then manufactured and the pressure drops are evaluated as a function of the input current (magnetic field). A hydraulic circuit with magnetorheological valves is formulated to control the height of the lift with an accuracy of ±1 mm with a load of 2000 kg on the each lifts. It is experimentally demonstrated that ramp and sinusoidal positions (or height) are well tracked within the targeted accuracy by controlling the magnetorheological valves. In addition, it is shown that the tilted position of the loaded vehicle with an eccentric mass placed on the lift is well controlled showing the balanced height.

23 October 2021 in Journal of Computational Design and Engineering
Verified
Journal Article
Open access
TLTae-Hoon Lee
Tae-Hoon Lee
DCDongeun Choi
Dongeun Choi
WLWoosub Lee
Woosub Lee
Robot-assisted surgery has been extensively applied in various microsurgical disciplines owing to its enhanced accuracy and dexterity based on the motion-scaling function between a hand and a surgical instrument. However, the surgical robot system developed thus far incurs high manufacturing costs and restricted compatibility due to the complicated control system, including many actuators and sensors. This paper proposes a novel passive mechanism for motion scaling based on the pantograph structure to resolve these drawbacks of robotic assistance devices. As a first step, a design configuration featuring gravity compensation and the duplication of directional motion is suggested. Subsequently, the geometric dimensions required to satisfy the surgical space and structural constraints are defined. Moreover, the mass of elements required to enable gravity compensation is calculated using moment equations. After determining the principal design parameters, the motion scaling of the proposed passive model is identified using a three-dimensional computer-aided design. In addition, for an extremely precise operation in microsurgery, the dynamic reaction force is expected to be constant in any location. Therefore, to investigate dynamic dexterity, the mathematical model is formulated based on the Lagrangian dynamic equation. Then, the dynamic workspace range is analysed from the determinant of the mass matrix. In addition, the analysis results are evaluated through comparative simulations in different workspace ranges; hence, a constant reaction force can be achieved only in the dynamic workspace range.

6 October 2009 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
TLTae-Hoon Lee
Tae-Hoon Lee
HKHodong Kim
Hodong Kim
A passive neutron coincidence counter was developed for the nondestructive measurements of the nuclear materials in the Advanced Spent Fuel Conditioning Process (ACP) facility at the Korea Atomic Energy Research Institute (KAERI). A hot test of the neutron counter was performed with spent fuel rod-cuts to obtain the calibration curve for 244Cm in 2007. The source terms were analyzed by using the ORIGEN-ARP code. There was a considerable difference in the neutron counting rates between the measurements and the MCNPX simulation results. This difference was systematic and came from the errors in the declared 244Cm mass obtained by using the burnup code. To correct the calibration curve, a self-multiplication correction method was applied, and the corrected singles and doubles rates as well as the expected 244Cm mass of each rod-cut were obtained as a result. The differences in the calibration constants between the measurements and the MCNPX results were - 33% and - 34% for the singles and doubles rates, respectively. However, those differences between the self-multiplication correction and MCNPX results were reduced to - 1% and - 5% for the singles and doubles rates, respectively.

21 April 2023 in Journal of Computational Design and Engineering
Verified
Journal Article
Open access
PDF file
TLTae-Hoon Lee
Tae-Hoon Lee
DCDongeun Choi
Dongeun Choi
CKChunwoo Kim
Chunwoo Kim
Robot assistance can improve the outcome of microsurgery by scaling down the surgeon’s hand motions. However, the high cost of surgical robots has prevented their use in small hospitals or medical facilities in several developing countries. As a novel alternative, a fully mechanical motion-scaling instrument, which can be operated without computers and motors, was proposed based on the pantograph mechanism. However, it had several problems owing to the cumbersome and heavy structures during the prototype test. This study aims solving the problems found in the first design and proving the advantages of the improvement, based on the design and performance criteria. The pantograph structure was simplified, and the gravity compensation method was modified to reduce inertia by using a constant force spring instead of a counter-mass. The improvement was computationally predicted using a mathematical model, and the results were verified through trajectory measurements in a micropositioning task. Finally, the evaluation of dynamic performance is quantitatively presented through iterative positioning tasks.