Nicolas Boulant

Nicolas Boulant

Auto-generated profile, based on publicly available information

Nicolas Boulant

University of Paris‐Saclay, CEA, CNRS, BAOBAB, NeuroSpin Gif sur Yvette France

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 February 2016 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
VGVincent Gras
Vincent Gras
AVAlexandre Vignaud
Alexandre Vignaud
AAAlexis Amadon
Alexis Amadon
DBDenis Le Bihan
Denis Le Bihan
NBNicolas Boulant
Nicolas Boulant

18 July 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
CSCaroline Le Ster
Caroline Le Ster
AGAndrea Grant
Andrea Grant
PMPierre‐François Van de Moortele
Pierre‐François Van de Moortele
AMAlejandro Monreal‐Madrigal
Alejandro Monreal‐Madrigal
GAGregor Adriany
Gregor Adriany
NBNicolas Boulant
Nicolas Boulant
Purpose: The SNR at the center of a spherical phantom of known electrical properties was measured in quasi‐identical experimental conditions as a function of magnetic field strength between 3 T and 11.7 T.Methods: The SNR was measured at the center of a spherical water saline phantom with a gradient‐recalled echo sequence. Measurements were performed at NeuroSpin at 3, 7, and 11.7 T. The phantom was then shipped to Maastricht University and then to the University of Minnesota for additional data points at 7, 9.4, and 10.5 T. Experiments were carried out with the exact same type of birdcage volume coil (except at 3 T, where a similar coil was used) to attempt at isolating the evolution of SNR with field strength alone. Phantom electrical properties were characterized over the corresponding frequency range.Results: Electrical properties were found to barely vary over the frequency range. Removing the influence of the flip‐angle excitation inhomogeneity was crucial, as expected. After such correction, measurements revealed a gain of SNR growing as B01.94 ± 0.16 compared with B02.13 according to ultimate intrinsic SNR theory.Conclusions: By using quasi‐identical experimental setups (RF volume coil, phantom, electrical properties, and protocol), this work reports experimental data between 3 T and 11.7 T, enabling the comparison with SNR theories in which conductivity and permittivity can be assumed to be constant with respect to field strength. According to ultimate SNR theory, these results can be reasonably extrapolated to the performance of receive arrays with greater than about 32 elements for central SNR in the same spherical phantom.

17 October 2024 in Nature Methods
Verified
Journal Article
Open access
PDF file
NBNicolas Boulant
Nicolas Boulant
Franck MauconduitFranck Mauconduit
Franck Mauconduit
VGVincent Gras
Vincent Gras
AAAlexis Amadon
Alexis Amadon
CSCaroline Le Ster
Caroline Le Ster
DBDenis LE BIHAN
Denis LE BIHAN
The understanding of the human brain is one of the main scientific challenges of the twenty-first century. In the early 2000s, the French Atomic Energy Commission launched a program to conceive and build a human magnetic resonance imaging scanner operating at 11.7 T. We have now acquired human brain images in vivo at such a magnetic field. We deployed parallel transmission tools to mitigate the radiofrequency field inhomogeneity problem and tame the specific absorption rate. The safety of human imaging at such high field strength was demonstrated using physiological, vestibular, behavioral and genotoxicity measurements on the imaged volunteers. Our technology yields T2 and T2*-weighted images reaching mesoscale resolutions within short acquisition times and with a high signal and contrast-to-noise ratio.

29 November 2017 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
VGVincent Gras
Vincent Gras
Franck MauconduitFranck Mauconduit
Franck Mauconduit
AVAlexandre Vignaud
Alexandre Vignaud
AAAlexis Amadon
Alexis Amadon
DBDenis Le Bihan
Denis Le Bihan
NBNicolas Boulant
Nicolas Boulant

30 January 2023 in Magnetic Resonance Materials in Physics, Biology and Medicine
Verified
Journal Article
Open access
PDF file
NBNicolas Boulant
Nicolas Boulant
LQLionel Quettier
Lionel Quettier
Objectives: The Iseult MRI is an actively shielded whole-body magnet providing a homogeneous and stable magnetic field of 11.7 T. After nearly 20 years of research and development, the magnet successfully reached its target field strength for the first time in 2019. This article reviews its commissioning status, the gradient–magnet interaction test results and first imaging experience. Materials and methods: Vibration, acoustics, power deposition in the He bath, and field monitoring measurements were carried out. Magnet safety system was tested against outer magnetic perturbations, and calibrated to define a safe operation of the gradient coil. First measurements using parallel transmission were also performed on an ex-vivo brain to mitigate the RF field inhomogeneity effect. Results: Acoustics measurements show promising results with sound pressure levels slightly above the enforced limits only at certain frequency intervals. Vibrations of the gradient coil revealed a linear trend with the B0 field only in the worst case. Field monitoring revealed some resonances at some frequencies that are still under investigation. Discussion: Gradient-magnet interaction tests at up to 11.7 T are concluded. The scanner is now kept permanently at field and the final calibrations are on-going to pave the road towards the first acquisitions on volunteers.

4 August 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
LDL. Van Damme
L. Van Damme
FMF. Mauconduit
F. Mauconduit
TCT. Chambrion
T. Chambrion
NBN. Boulant
N. Boulant
VGV. Gras
V. Gras