1 September 2000 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
1 January 2008 in Journal of Applied Physics
The focus of this paper is to evaluate thick, and , cadmium zinc telluride (CZT), , crystals grown using the traveling heater method (THM). The phenomenal spectral performance and small size and low concentration of Te inclusions/precipitates of these crystals indicate that the THM is suitable for the mass production of CZT radiation detectors that can be used in a variety of applications. Our result also proves that with careful material selection using IR and high-quality fabrication processes, the theoretical energy resolution limit can be achieved.
15 September 2002 in Journal of Applied Physics
Gamma-ray spectroscopy is a valuable tool of science and technology. Many applications for this tool are in need of a detector technology capable of achieving excellent energy resolution and efficient detection while operating at room temperature. Detectors based on the material cadmium zinc telluride (CdZnTe) could potentially meet this need if certain material deficiencies are addressed. The coplanar-grid as well as other electron-only detection techniques are effective in overcoming some of the material problems of CdZnTe and, consequently, have led to efficient gamma-ray detectors with good energy resolution while operating at room temperature. At the present time, the performance of these detectors is limited mainly by the degree of uniformity in electron generation and transport. Despite recent progress in the growth of CdZnTe material, small variations in these properties remain a barrier to the widespread success of such detectors. Alpha-particle response characterization of CdZnTe crystals fabricated into simple planar detectors provides an effective tool to accurately study such variations. We have used a finely collimated alpha source to produce two-dimensional maps of detector response. For a number of crystals, a clear correlation has been observed between their alpha response maps and the distribution of tellurium inclusions inside the crystals. An analysis of the induced charge signals indicates that regions of enhanced electron trapping are associated with the inclusions, and that these regions extend beyond the physical size of the inclusions. Such regions introduce nonuniform electron trapping in the material that then degrades the spectroscopic performance of the material as a gamma-ray detector.
1 September 2007 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
16 June 2009 in IEEE Transactions on Nuclear Science
Over 25 1-cm3 CdZnTe crystals produced using the Traveling Heater Method at Redlen Technologies have been characterized. The charge carrier mobility and lifetime, and charge carrier transport uniformity of each crystal were measured using alpha particles. Some of the crystals were made into coplanar-grid detectors and their performance characterized using 662 keV gamma rays. The average electron mobility-lifetime product for these crystals was found to be a factor of about five times greater than that measured from crystals obtained over the last decade from two other commercial crystal growers. The coplanar-grid detectors produced from the material typically achieved an energy resolution at 662 keV near 2% FWHM when operated at room temperature. This is comparable to the best coplanar-grid detectors commercially produced today.
9 November 2012 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment