Jing-Shang Zhang

Jing-Shang Zhang

Auto-generated profile, based on publicly available information

Jing-Shang Zhang

Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing, China

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2005 in Communications in Theoretical Physics
Verified
Journal Article
Closed access
PDF file
YYYu-Liang Yan
Yu-Liang Yan
JDJun-Feng Duan
Jun-Feng Duan
XSXiao-Jun Sun
Xiao-Jun Sun
JWJi-Min Wang
Ji-Min Wang
JZJing-Shang Zhang
Jing-Shang Zhang
By using a new reaction model for light nuclei, the double-differential cross section of n + 14N reactions at En = 14.2 MeV has been analyzed. In the case of n+14N reactions, the reaction mechanism is very complex, there are over one hundred opened partial reaction channels even at incident energy En = 14.2 MeV. In this paper the opened reaction channels are listed in detail. With LUNF code the model calculation is performed to analyze the double-differential cross sections of total outgoing neutron. The calculated results agree fairly with the experimental data. The results indicate that the pre-equilibrium mechanism dominates the whole reaction processes, and the recoil effect in light nuclear reactions is essentially important. 5He emission has been considered, but it is only a small contribution to the double-differential cross section at incident energy En = 14.2 MeV.

15 May 2001 in Communications in Theoretical Physics
Verified
Journal Article
Closed access
ZJZhang Jing-Shang
Zhang Jing-Shang
HYHan Yin-Lu
Han Yin-Lu
Xiaoli FanXiaoli Fan
Xiaoli Fan

1 October 2025 in Clinical Ophthalmology
Verified
Journal Article
Open access
PDF file
YJYu-Feng Jian
Yu-Feng Jian
JZJing-Shang Zhang
Jing-Shang Zhang
XWXiu-Hua Wan
Xiu-Hua Wan
Glucocorticoids (GCs) remain a cornerstone therapy for noninfectious uveitis and autoimmune disorders; however, chronic administration is strongly associated with sight-threatening complications, particularly glucocorticoid-induced cataracts (GIC). This comprehensive review synthesizes current evidence on the molecular pathogenesis, epidemiological patterns, and clinical management of GIC. Epidemiological analyses indicate that over 50% of patients receiving systemic corticosteroids for > 60 days develop ocular complications, with cataract formation (36%) and glaucoma (16%) representing the predominant sequelae. Histopathologically, GIC manifests as posterior subcapsular opacities, mechanistically linked to oxidative stress, epithelial-mesenchymal transition (EMT), vimentin dysregulation, Na+/K+-ATPase inhibition, apoptosis, and endoplasmic reticulum (ER) stress. Risk stratification models identify cumulative GC dose (> 20,000 mg/m² prednisolone equivalents), treatment duration (> 6 months), and administration route (oral > topical > intravitreal) as critical determinants of cataractogenesis. Although early-stage GIC is clinically silent, progressive opacification leads to debilitating visual acuity loss, photophobia, and impaired quality of life. Current interventions encompass antioxidants, molecular targeting strategies, advanced drug delivery systems, and glucocorticoid-sparing agents. Through systematic integration of epidemiology, pathogenesis, and therapeutic advances, we aim to resolve the GC therapeutic paradox and provide robust frameworks for future clinical management.

5 March 2026 in International Ophthalmology
Verified
Journal Article
Open access
PDF file
GLGuang-Yue Li
Guang-Yue Li
ZLZhong-Yan Li
Zhong-Yan Li
ZYZhao-Heng Yang
Zhao-Heng Yang
PZPeng Zhao
Peng Zhao
MLMeng Li
Meng Li
JZJing-Shang Zhang
Jing-Shang Zhang
Purpose To investigate the accuracy, stability, and influencing factors of 12 intraocular lens (IOL) calculation formulas in highly myopic cataract patients. Methods Retrospective Case Series. Clinical data were collected from highly myopic cataract patients who underwent cataract extraction surgery at Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, between January 2024 and January 2025. Patients were stratified into subgroups based on axial length, keratometry, anterior chamber depth and axial length to corneal radius ratio (AL/r). The prediction error (PE), absolute error (AE), root-mean-square absolute prediction error (RMSAE) and the percentage of eyes with an absolute error within ± 0.25 D, ± 0.50 D, ± 0.75 D, and ± 1.00 D were recorded and compared for the following 12 IOL formulas: Barrett Universal II, Cooke K6, Castrop, Kane, EVO 2.0, Pearl-DGS, Hoffer QST, SRK-T, Haigis, Holladay 1, Holladay 2, and Hoffer Q. Statistical analysis was performed using Analysis of Variance (ANOVA), Friedman test, Kruskal–Wallis test, Dunn's test, and Cochran Q test. Results A total of 255 patients (255 eyes) were included in this study, comprising 113 males and 142 females, with a mean age of 57.8 ± 9.9 years. The difference in absolute errors among the 12 IOL formulas was statistically significant (χ2 = 327.59, P < 0.01). Among them, the Hoffer QST formula yielded the lowest absolute error (0.33 D), followed by Pearl-DGS (0.35 D) and Barrett UII 0.35 D), while the Hoffer Q formula showed the highest absolute error (0.75 D). Notably, only the Hoffer QST and Pearl-DGS formulas demonstrated no significant correlation between their absolute errors and axial length, corneal curvature, or anterior chamber depth (all P > 0.05). Conclusion For highly myopic cataract patients, modern IOL formulas demonstrated superior accuracy compared to traditional formulas. The accuracy was predominantly influenced by axial length, with keratometry and anterior chamber depth playing minor roles. The Hoffer QST and Pearl-DGS formulas, in particular, showed consistent and stable performance.

22 January 2026 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
GLGuang-Yue Li
Guang-Yue Li
PZPeng Zhao
Peng Zhao
ZLZhong-Yan Li
Zhong-Yan Li
ZYZhao-Heng Yang
Zhao-Heng Yang
MLMeng Li
Meng Li
JZJing-Shang Zhang
Jing-Shang Zhang
To investigate the influence of keratometry on the predictive accuracy of modern IOL formulas in determining optimal IOL power for cataract patients with h

17 September 2025 in European Journal of Ophthalmology
Verified
Journal Article
Closed access
ZGZhao-Xing Guo
Zhao-Xing Guo
MLMeng Li
Meng Li
JZJing-Shang Zhang
Jing-Shang Zhang
YMYing-Yan Mao
Ying-Yan Mao
ZTZhi-Yong Tian
Zhi-Yong Tian
XWXiu-Hua Wan
Xiu-Hua Wan
Objective: To analyze and compare the accuracy of different intraocular lens power calculation formulas in patients with cataract after radial keratotomy. Methods: Web of Science, Cochrane Library, EMBASE and PubMed were searched for clinical studies published from the establishment of the database to 10th May 2024. Measurements were taken as percentage of eyes of prediction errors within ±0.5 D and ±1.0 D. A network meta-analysis was utilized to compare the different formulas as a way to identify the most advantageous ones. Results: Results from 11 studies of 674 eyes after radial keratotomy that used 24 formulas were included. A network meta-analysis indicated that for error within the range of ± 0.5 D, Barrett true-K History and Barrett true-K Partial History were better than Double-K Holladay 1. Intraoperative Aberrometry, Double-K SRK/T, Haigis and Barrett true-K No History performed as well or better than Double-K Holladay 1. Shammas No History and Holladay 1 had poor performance. For error within the range of ±1.0 D, Shammas No History and Barrett Universal II had poor performance. No statistically significant difference was observed between the other formulas. Conclusions: For cataract patients after radial keratotomy, Barrett true-K History and Barrett true-K Partial History were recommended if the prior medical history were available. Otherwise, no single formula is more advantageous without reference to prior medical history.