Jurandir Antonio Barbosa

Jurandir Antonio Barbosa

Auto-generated profile, based on publicly available information

Jurandir Antonio Barbosa

Faculdade São Leopoldo Mandic, Brazil

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 April 2020 in Journal of Bio- and Tribo-Corrosion
Verified
Journal Article
Closed access
PDF file
CNCarolina Assis Do Nascimento
Carolina Assis Do Nascimento
JBJurandir Antonio Barbosa
Jurandir Antonio Barbosa
VMVictor Angelo Martins Montalli
Victor Angelo Martins Montalli
FMFábio Micheletti
Fábio Micheletti
RMRodrigo Milani
Rodrigo Milani
RBRoberta Tarkany Basting
Roberta Tarkany Basting

1 January 2024 in Internet of Things and Cyber-Physical Systems
Verified
Journal Article
Open access
EMEdson Mota
Edson Mota
JBJurandir Barbosa
Jurandir Barbosa
Gustavo FigueiredoGustavo Figueiredo
Gustavo Figueiredo
MPMaycon Peixoto
Maycon Peixoto
Cassio Vinicius Serafim PrazeresCassio Vinicius Serafim Prazeres
Cassio Vinicius Serafim Prazeres

1 January 2024 in Dental Press Journal of Orthodontics
Verified
Journal Article
Open access
PDF file
SFStaell Ribeiro de Faria
Staell Ribeiro de Faria
TATúlio Rodrigues de Andrade
Túlio Rodrigues de Andrade
CACristiane Barros André
Cristiane Barros André
VMVictor Angelo Martins Montalli
Victor Angelo Martins Montalli
JBJurandir Antonio Barbosa
Jurandir Antonio Barbosa
RBRoberta Tarkany Basting
Roberta Tarkany Basting
Objective: Evaluate the load mini-implants exert on the artificial bone when expanding the MARPE EX in three different extension arm configurations. Methods: A device simulating the human palate was fabricated and attached to a universal testing machine, for conducting tests with different MARPE expanders (n=5): non-adjustable/control (MARPE SL, Peclab) or with low, intermediate, and high extender arms (MARPE EX, Peclab). The expanders were manually activated until failure of the device occurred, and maximum load values were recorded. Load averages were also calculated for every five activations until the twentieth activation. Results: The generalized linear mixed model for repeated measures over time showed that there was significant increase in load with activations for all expanders (p=0.0004). Up to the twentieth activation, the expander with low extender arms presented higher load than the others, while the expander with high extender arms showed lower load values (p<0.05). There was no significant difference among expanders regarding the number of activations (p=0.0586), although there was a trend towards fewer activations until fracture for the control expander. It was observed that the higher the configuration, the lower the force the mini-implants delivered to the bone. The control expander provided a force magnitude similar to that of the adjustable expander when positioned at the intermediate height. Conclusions: The activation load of MARPE expanders is influenced by the type of presentation of the extensor arms, with higher configurations resulting in lower force delivered by the mini-implants to the bone.