Hong Jang

Hong Jang

Auto-generated profile, based on publicly available information

Hong Jang

Department of Radiology, Samsung Changwon Hospital, Sungkyunkwan University School of Medicine

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 July 2026 in medRxiv
Verified
Preprint
Open access
PDF file
YNYoojin Nam
Yoojin Nam
TATaein An
Taein An
SHSung Il Hwang
Sung Il Hwang
HJHong Jang
Hong Jang
CJChawoong Jeon
Chawoong Jeon
Namkug KimNamkug Kim
Namkug Kim
Background: Frontier text-to-image models can synthesise radiologic images of high realism, raising the question of whether expert radiologists can serve as a provenance safeguard for the medical image record. Methods: We conducted a prospective, pre-registered visual Turing test in which 60 invited Korean board-certified radiology faculty and trainees judged authentic (teaching-repository) and AI-generated radiologic images from a locked pool of 241 displayable cells (82 entities; nine subspecialties; six modalities; 60 readers x 60 trials = 3,600 reader–image observations) produced by two contemporary commercial generators. The primary endpoint was the confidence-weighted, reader-averaged multi-reader multi-case area under the curve for AI versus authentic images, conditional on the locked image pool; the key secondary endpoint was the Faculty-minus-Junior difference under a two one-sided tests equivalence framework. The pre-specified statistical analysis plan was registered on the Open Science Framework before data lock. Findings: All 60 readers completed the test. The pooled confidence-weighted area under the curve was 0.71 (95% CI, 0.69 to 0.74), above the null value of 0.5 but within the pre-specified modest tier (0.60 to 0.75). The Faculty-minus-Junior contrast was 0.04 (95% CI, −0.02 to 0.10), including zero, and the two one-sided tests established equivalence within the +/−0.10 margin. No reader stratum and no pre-specified sensitivity analysis reached the deployable-classifier threshold (area under the curve >= 0.75). Interpretation: In this single-country cohort, expert radiologists distinguished frontier-generated from authentic radiologic images only modestly, without a meaningful expertise gradient (equivalence within +/−0.10) and with no reader stratum reaching a standalone provenance safeguard. These findings support radiology AI-literacy training and pipeline-level provenance safeguards rather than reliance on reader judgment, and warrant retesting in an independent reader cohort. Funding: This research was supported by a grant of the Korea Health Technology R&D Project through the Korea Health Industry Development Institute (KHIDI), funded by the Ministry of Health & Welfare, Republic of Korea (grant number: RS-2025-02213531).