Timofei Istomin

Timofei Istomin

Auto-generated profile, based on publicly available information

Timofei Istomin

Univ. of Trento, Trento, Italy

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2018
Verified
Conference Paper
Closed access
TITimofei Istomin
Timofei Istomin
MTMatteo Trobinger
Matteo Trobinger
AMAmy Lynn Murphy
Amy Lynn Murphy
GPGian Pietro Picco
Gian Pietro Picco
Aperiodic data collection received little attention in wireless sensor networks, compared to its periodic counterpart. The recent Crystal system uses synchronous transmissions to support aperiodic traffic with near-perfect reliability, low latency, and ultra-low power consumption. However, its performance is known under mild interference-a concern, as Crystal relies heavily on the (noise-sensitive) capture effect and targets aperiodic traffic where "every packet counts". We exploit a 49-node indoor testbed where, in contrast to existing evaluations using only naturally present interference to evaluate synchronous systems, we rely on JamLab to generate noise patterns that are not only more disruptive and extensive, but also reproducible. We show that a properly configured, unmodified Crystal yields perfect reliability (unlike Glossy) in several noise scenarios, but cannot sustain extreme ones (e.g., an emulated microwave oven near the sink) that instead are handled by routing-based approaches. We extend Crystal with techniques known to mitigate interference-channel hopping and noise detection-and demonstrate that these allow Crystal to achieve performance akin to the original even under multiple sources of strong interference.

24 June 2017 in Annals of Critical Care
Verified
Journal Article
Open access
TIT. A. Istomin
T. A. Istomin
IKIliya S. Kurapeev
Iliya S. Kurapeev
Objectives. The study presents the results of quality assessment of antiischemic myocardial protection by low-volume method of cardioplegia by Custodiol solution during operations with cardiopulmonary bypass. Material and Methods. The study involved 57 patients who underwent different cardiosurgery operations with cardiopulmonary bypass. The patients were divided into two groups on the basis of the volume of cardioplegic solution. Research group (group 1) consists of 33 patients who were administered Custodiol in low volume limited by 1000 ml. The control group (group 2) consists of 24 patients who were administered standart volume of the solution corresponding to the manufacturer’s instructions: 1 ml per 1 g of myocardial mass during 6–8 minutes. Results. The volume of Custodiol administered per 1 kg of body weight was 12.7 ± 2.0 and 22.7 ± 4 ml and 4.0 ± 1.3 and 6.3 ± 1.9 ml per 1 g of myocardial mass in groups 1 and 2, respectively (p < 0.001). The frequency of catecholamines usage, temporary cardiac pacing and other adverse events with a small-volume cardioplegia technique with Custodiol solution did not differ significantly. The results has indicated that the use of low volume of cardioplegic Custodiol in a single administration manner provides a complete antiischemic protection of the myocardium during the correction of valvular heart disease, including combination with coronary artery bypass grafting. Conclusion. Usage of low volume Custodiol solution method does not increase the need of inotropic and vasopressor usage and pacing time.