Bruno Salles Sotto-Maior

Bruno Salles Sotto-Maior

Auto-generated profile, based on publicly available information

Bruno Salles Sotto-Maior

Professor, Department of Restorative Dentistry, School of Dentistry, Federal University of Juiz de Fora (UFJF), Juiz de Fora, MG, Brazil

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2014 in Journal of Periodontology
Verified
Journal Article
Closed access
JMJose Alfredo Mendonça
Jose Alfredo Mendonça
CFCarlos Eduardo Francischone
Carlos Eduardo Francischone
PSPlinio Senna
Plinio Senna
AOAna Elisa Matos de Oliveira
Ana Elisa Matos de Oliveira
BSBruno Salles Sotto‐Maior
Bruno Salles Sotto‐Maior
Background: The aim of the present study is to evaluate the survival rate and bone loss around short implants (≤10 mm) supporting splinted or non‐splinted posterior prostheses during a follow‐up period of 3 to 16 years.Methods: A total of 453 implants from 198 patients was divided into splinted or non‐splinted groups. Implant survival rate was calculated for each group, and potential risk was represented as odds ratio (OR). The final linear distance from implant platform level to the first bone‐to‐implant contact was compared to this same reference just after loading by digital periapical radiographs to determine the marginal bone loss (BL).Results: The splinted group comprised 219 implants in 86 patients, whereas the non‐splinted group included 234 implants from 112 patients. The mean follow‐up period was 9.7 ± 3.7 years. Although different success rates were found for splinted (97.7%) and non‐splinted (93.2%) groups, they exhibited similar BL (1.22 ± 0.95 mm and 1.27 ± 1.15 mm, respectively). The success of splinted implants was associated with no other variable, whereas non‐splinted implants exhibited higher risk of failure when placed in men (OR = 3.2) and when implants shorter than 10 mm were used (OR = 3.6 and 4.1 for 8.5 mm and 7 mm, respectively). Regardless of group, 71.4% of the unsuccessful implants failed before the end of the first year after loading.Conclusion: Non‐splinted posterior short implants had a somewhat lower success rate than splinted short implants, and the failure rate in non‐splinted short implants appeared to be greater in males as well as in implants ≤10 mm.

1 March 2013 in The International Journal of Oral and Maxillofacial Implants
Verified
Journal Article
Closed access
MRMarcio Borges Rosa
Marcio Borges Rosa
BSBruno Salles Sotto-Maior
Bruno Salles Sotto-Maior
VMVinicius de Carvalho Machado
Vinicius de Carvalho Machado
CFCarlos Eduardo Francischone
Carlos Eduardo Francischone
Marcio Borges Rosa, DDS, Ms, PhD/Bruno Salles Sotto-Maior, DDS, Ms, PhD/Vinicius de Carvalho Machado, DDS/Carlos Eduardo Francischone DDS, Ms, PhD: Purpose: The mental foramen is an important landmark during surgical procedures such as osseous grafting or the placement of dental implants. To avoid injuring the mental nerve, it is important both to carefully assess the location of the mental foramen and to determine whether an anterior loop of the mental nerve or the incisive canal lies mesial to it. The objective of this study was to quantify the ability of cone beam computed tomography (CBCT) to measure the length of the mental nerve loop, the length and diameter of the incisive nerve canals, and the incisive canal path. Materials and Methods: The study included 352 CBCT scans that had originally been used for preoperative planning of implant placement in the interforaminal region of the anterior mandible. For each scan, the length of the mental nerve loop and the length, diameter, and path of the incisive canal were determined. Mean values were compared between groups based on sex, right versus left side, and whether the patient was edentulous. Results: The inferior alveolar nerve loop and incisive canal had a mean length of 2.40 ? 0.93 mm and 9.11 ? 3.00 mm, respectively. The mean incisive canal diameter was 1.48 ? 0.66 mm and showed a downward path in 51.3% of CBCT images and a linear or upward path in 38.29% and 10.41% of scans, respectively. Conclusions: CBCT provides an accurate means to identify critical anatomical features in the anterior mandible during preoperative surgical planning. J Oral Maxillofac Implants 2013;28:388?392. doi: 10.11607/jomi.2648

1 January 2013 in The International Journal of Oral and Maxillofacial Implants
Verified
Journal Article
Closed access
DVDalton Marinho Vieira
Dalton Marinho Vieira
BSBruno Salles Sotto-Maior
Bruno Salles Sotto-Maior
CBCarlos Alberto Villaça de Souza Barros
Carlos Alberto Villaça de Souza Barros
ERElson Simões Reis
Elson Simões Reis
CFCarlos Eduardo Francischone
Carlos Eduardo Francischone
Dalton Marinho Vieira, DDS, MS, PhD/Bruno Salles Sotto-Maior, DDS, MS, PhD/Carlos Alberto Villa?a de Souza Barros, DDS, MS/Elson Sim?es Reis, DDS, MS, PhD/Carlos Eduardo Francischone, DDS, MS, PhD: Purpose: Although flapless computer-guided implant placement provides important benefits, deviations from the planned implant placement in the edentulous arch may pose significant risks. This study evaluated the reliability and accuracy of a flapless computer-guided surgical approach. Materials and Methods: Computer-generated preoperative implant planning was compared to actual placement by cone-beam computerized tomography (CBCT) scanning of patients before and after surgery. A well-fitting complete denture or optimized prosthetic tooth arrangement was used and converted to a radiographic template. Prior to scanning, esthetics and functional aspects were checked clinically. The implant positions were virtually determined by the implant planning software relative to the bone structure and prospective tooth position. After implant placement, new CBCT scans were obtained for each subject. Software was used to fuse the images of the planned and placed implants, and the locations and axes were compared. The normality of the data distribution was evaluated by the Kolmogorov-Smirnov test. Mean values were compared between groups based on the upper or lower jaws with the t test for independent samples. The level of significance was fixed at 5%. Results: Sixty-two implants were placed in edentulous arches with stereolithographic surgical guides in 14 patients. Damage due to implant placement was not observed in any critical anatomical structure. Compared to the planned implants, placed implants showed mean and standard deviation linear measurements at the cervical, middle, and apical implant portions of 2.17 (? 0.87), 2.32 (? 1.52), and 2.86 (? 2.17) mm, for the maxilla, and 1.42 (? 0.76), 1.42 (? 0.76), and 1.42 (? 0.76) mm, for the mandible, respectively. The angular deviations were 1.93 (? 0.17) and 1.85 (? 0.75) degrees for the maxilla and mandible, respectively. The linear deviation differed significantlybetween the upper and lower jaws, but the angular deviation did not. Conclusion: Flapless computer-guided surgery may be a viable treatment option for rehabilitating the edentulous arch.

1 November 2014 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
MCMarco Aurélio Carvalho
Marco Aurélio Carvalho
BSBruno Salles Sotto-Maior
Bruno Salles Sotto-Maior
ACAltair Antoninha Del Bel Cury
Altair Antoninha Del Bel Cury
GHGuilherme Elias Pessanha Henriques
Guilherme Elias Pessanha Henriques

1 January 2014 in International Journal of Periodontics & Restorative Dentistry
Verified
Journal Article
Closed access
JRJosé Carlos Martins da Rosa
José Carlos Martins da Rosa
ARAriádene Cristina Pértile de Oliveira Rosa
Ariádene Cristina Pértile de Oliveira Rosa
CFCarlos Eduardo Francischone
Carlos Eduardo Francischone
BSBruno Salles Sotto-Maior
Bruno Salles Sotto-Maior
Jos? Carlos Martins da Rosa, DDS, MSc/Ari?dene Cristina P?rtile de Oliveira Rosa, DDS, MSc/Carlos Eduardo Francischone, DDS, MSc, PhD/Bruno Salles Sotto-Maior, DDS, MSc, PhD: The aim of this prospective case series was to evaluate the stability of esthetic treatment after single tooth replacement in compromised sockets using the immediate dentoalveolar restoration (IDR) concept. Eighteen patients underwent immediate implant placement and IDR of bone defects. Clinical photographs were used to evaluate the gingival contour and papillae. The mean soft tissue dimensions at baseline and final follow-up were 12.85 ? 2.33 mm and 12.79 ? 2.48 mm, respectively, revealing no recession. The mean mesial and distal papillary heights increased slightly over time. Stable periimplant soft tissues and satisfactory esthetic outcomes were achieved. (Int J Periodontics Restorative Dent 2014;34:199?208. doi: 10.11607/prd.1858)

1 March 2017 in The International Journal of Oral and Maxillofacial Implants
Verified
Journal Article
Closed access
CACamila Lima de Andrade
Camila Lima de Andrade
MCMarco Carvalho
Marco Carvalho
DBDimorvan Bordin
Dimorvan Bordin
WSWander da Silva
Wander da Silva
ACAltair Antoninha Del Bel Cury
Altair Antoninha Del Bel Cury
BSBruno Sotto-Maior
Bruno Sotto-Maior
Camila Lima de Andrade, DDS, MSc, PhD/Marco Aur?lio Carvalho, DDS, MSc/Dimorvan Bordin, DDS, MSc/Wander Jos? da Silva, DDS, MSc, PhD/Altair Antoninha Del Bel Cury, DDS, MSc, PhD/Bruno Salles Sotto-Maior, DDS, MSc, PhD: Purpose: The aim of this study was to evaluate the influence of implant macrodesign when using different types of collar and thread designs on stress/strain distributions in a maxillary bone site. Materials and Methods: Six groups were obtained from the combination of two collar designs (smooth and microthread) and three thread shapes (square, trapezoidal, and triangular) in external hexagon implants (4 ? 10 mm) supporting a single zirconia crown in the maxillary first molar region. A 200-N axial occlusal load was applied to the crown, and measurements were made of the von Mises stress (σvM) for the implant, and tensile stress (σmax), shear stress (τmax), and strain (εmax) for the surrounding bone using tridimensional finite element analysis. The main effects of each level of the two factors investigated (collar and thread designs) were evaluated by one-way analysis of variance (ANOVA) at a 5% significance level. Results: Collar design was the main factor of influence on von Mises stress in the implant and stresses/strain in the cortical bone, while thread design was the main factor of influence on stresses in the trabecular bone (P < .05). The optimal collar design able to produce more favorable stress/strain distribution was the microthreaded design for the cortical bone. For the trabecular bone, the triangular thread shape had the lowest stresses and strain values among the square and trapezoidal implants. Conclusion: Stress/strain distribution patterns were influenced by collar design in the implant and cortical bone, and by thread design in the trabecular bone. Microthreads and triangular thread-shape designs presented improved biomechanical behavior in posterior maxillary bone when compared with the smooth collar design and trapezoidal and square-shaped threads.