Antonio Pazos Álvarez

Antonio Pazos Álvarez

Auto-generated profile, based on publicly available information

Antonio Pazos Álvarez

Univ Santiago Compostela, IGFAE, Santiago De Compostela, Spain

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2024 in Journal of Instrumentation
Verified
Journal Article
Open access
PDF file
RAR. Aaij
R. Aaij
AAA.S.W. Abdelmotteleb
A.S.W. Abdelmotteleb
CBC. Abellan Beteta
C. Abellan Beteta
FAF. Abudinén
F. Abudinén
CAC. Achard
C. Achard
SZS. Zvyagintsev
S. Zvyagintsev
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their selection in real time. The experiment's tracking system has been completely upgraded with a new pixel vertex detector, a silicon tracker upstream of the dipole magnet and three scintillating fibre tracking stations downstream of the magnet. The whole photon detection system of the RICH detectors has been renewed and the readout electronics of the calorimeter and muon systems have been fully overhauled. The first stage of the all-software trigger is implemented on a GPU farm. The output of the trigger provides a combination of totally reconstructed physics objects, such as tracks and vertices, ready for final analysis, and of entire events which need further offline reprocessing. This scheme required a complete revision of the computing model and rewriting of the experiment's software.

16 March 2022 in Royal Society Open Science
Verified
Journal Article
Open access
JBJan Buytaert
Jan Buytaert
PCPaula Collins
Paula Collins
AAAdam Abed Abud
Adam Abed Abud
PAPhil Allport
Phil Allport
AÁAntonio Pazos Álvarez
Antonio Pazos Álvarez
KWKen Wyllie
Ken Wyllie
A high-quality, low-cost ventilator, dubbed HEV, has been developed by the particle physics community working together with biomedical engineers and physicians around the world. The HEV design is suitable for use both in and out of hospital intensive care units, provides a variety of modes and is capable of supporting spontaneous breathing and supplying oxygen-enriched air. An external air supply can be combined with the unit for use in situations where compressed air is not readily available. HEV supports remote training and post market surveillance via a Web interface and data logging to complement standard touch screen operation, making it suitable for a wide range of geographical deployment. The HEV design places emphasis on the ventilation performance, especially the quality and accuracy of the pressure curves, reactivity of the trigger, measurement of delivered volume and control of oxygen mixing, delivering a global performance which will be applicable to ventilator needs beyond the COVID-19 pandemic. This article describes the conceptual design and presents the prototype units together with a performance evaluation.

1 June 2024 in Journal of Instrumentation
Verified
Journal Article
Open access
KAK. Akiba
K. Akiba
MAM. Alexander
M. Alexander
CBC. Bertella
C. Bertella
ABA. Biolchini
A. Biolchini
ABA. Bitadze
A. Bitadze
GZG. Zunica
G. Zunica
The LHCb detector has undergone a major upgrade for LHC Run 3. This Upgrade I detector facilitates operation at higher luminosity and utilises full-detector information at the LHC collision rate, critically including the use of vertex information. A new vertex locator system, the VELO Upgrade, has been constructed. The core element of the new VELO are the double-sided pixelated hybrid silicon detector modules which operate in vacuum close to the LHC beam in a high radiation environment. The construction and quality assurance tests of these modules are described in this paper. The modules incorporate 200 μm thick, n-on-p silicon sensors bump-bonded to 130 nm technology ASICs. These are attached with high precision to a silicon microchannel substrate that uses evaporative CO2 cooling. The ASICs are controlled and read out with flexible printed circuits that are glued to the substrate and wire-bonded to the chips. The mechanical support of the module is given by a carbon fibre plate, two carbon fibre rods and an aluminium plate. The sensor attachment was achieved with an average precision of 21 μm, more than 99.5% of all pixels are fully functional, and a thermal figure of merit of 3 Kcm2W-1 was achieved. The production of the modules was successfully completed in 2021, with the final assembly and installation completed in time for data taking in 2022.

21 April 2024 in arXiv
Verified
Preprint
Open access
PDF file
KAK. Akiba
K. Akiba
MAM. Alexander
M. Alexander
CBC. Bertella
C. Bertella
ABA. Biolchini
A. Biolchini
ABA. Bitadze
A. Bitadze
GZG. Zunica
G. Zunica
The LHCb detector has undergone a major upgrade for LHC Run 3. This Upgrade I detector facilitates operation at higher luminosity and utilises full-detector information at the LHC collision rate, critically including the use of vertex information. A new vertex locator system, the VELO Upgrade, has been constructed. The core element of the new VELO are the double-sided pixelated hybrid silicon detector modules which operate in vacuum close to the LHC beam in a high radiation environment. The construction and quality assurance tests of these modules are described in this paper. The modules incorporate 200 \mum thick, n-on-p silicon sensors bump-bonded to 130 \nm technology ASICs. These are attached with high precision to a silicon microchannel substrate that uses evaporative CO$_2$ cooling. The ASICs are controlled and read out with flexible printed circuits that are glued to the substrate and wire-bonded to the chips. The mechanical support of the module is given by a carbon fibre plate, two carbon fibre rods and an aluminium plate. The sensor attachment was achieved with an average precision of 21 $\mathrm{μm}$, more than 99.5\% of all pixels are fully functional, and a thermal figure of merit of 3 \mathrm{Kcm^{2}W^{-1}}$ was achieved. The production of the modules was successfully completed in 2021, with the final assembly and installation completed in time for data taking in 2022.

7 September 2026 in Journal of High Energy Physics
Verified
Journal Article
Open access
PDF file
CCC. Cortes-Parra
C. Cortes-Parra
PNP. Novella
P. Novella
GMG. Martínez-Lema
G. Martínez-Lema
HAH. Almazán
H. Almazán
VÁV. Álvarez
V. Álvarez
AYA. Yubero-Navarro
A. Yubero-Navarro
A bstract: The NEXT-100 detector at the LSC aims at the first competitive search for the 0 νββ decay using a high-pressure 136 Xe electroluminescent time projection chamber. The first low-background run of NEXT-100 at 3.95 bar has been devoted to the measurement of the radon-induced backgrounds impacting this search. The contributions from both the internal and external airborne radon have been evaluated. The internal 222 Rn activity is found to be (0.95 ± 0.04(stat) ± 0.09(sys)) Bq/m 3 , while no traces of 220 Rn have been observed. Most of the 222 Rn progeny plate-out on the surface of the cathode of the detector, leading to a rate of Rn-induced 214 Bi of (0.97 ± 0.05(stat) ± 0.10(sys)) Hz for visible energies above 400 keV. The corresponding background index in the 0 νββ region of interest is evaluated as (7.3 ± 1.5(stat) ± 0.8(sys)) × 10 − 4 counts/(keV · kg · yr) after selection of the fully contained events. This background index is reduced to ∼ 4 × 10 − 5 counts/(keV · kg · yr) by applying a topological selection requiring only one double-electron-like track in the events. This value is one order of magnitude below the total radiogenic background expectation in NEXT-100. By analyzing the correlation of the airborne radon activity and the measured rate of events in NEXT-100, it is concluded that the detector operates in a virtually radon-free environment thanks to the radon abatement system of the LSC.