Sandeep Manhas

Sandeep Manhas

Auto-generated profile, based on publicly available information

Sandeep Manhas

LPICM, Ecole Polytechnique, CNRS (France)

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 June 2013 in Optics Express
Verified
Journal Article
Open access
PDF file
APAngelo Pierangelo
Angelo Pierangelo
ANAndré Nazac
André Nazac
ABAbdelali Benali
Abdelali Benali
PVPierre Validire
Pierre Validire
HCHenri Cohen
Henri Cohen
AMAntonello-De Martino
Antonello-De Martino
We present a preliminary investigation of macroscopic polarimetric imaging of uterine cervix. Orthogonal state contrast (OSC) images of healthy and anomalous cervices have been taken in vivo at 550 nm. Four ex vivo cervix samples have been studied in full Muller polarimetry, at 550 nm and 700 nm, and characterized in detail by standard pathology. One sample was totally healthy, another one carried CIN lesions at very early stage (CIN1) in its visible exocervical region, while for the other two samples more advanced (CIN3) lesions were present, together with visible glandular epithelium (ectropion). Significant birefringence has been observed in the healthy regions of all six samples, both in vivo and ex vivo. Standard treatments of the Mueller images of the ex vivo samples allowed to quantify both retardation and depolarization. Retardation reached 60° in healthy regions, and disappeared in the anomalous regions of the other three ex vivo samples. The depolarization power was largest in healthy regions, and lower in CINs and ectropion. Possible origins of the observed effects are briefly discussed.

1 April 2013 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
APAngelo Pierangelo
Angelo Pierangelo
SMSandeep Manhas
Sandeep Manhas
ABAbdelali Benali
Abdelali Benali
CFClément Fallet
Clément Fallet
JTJean-Laurent Totobenazara
Jean-Laurent Totobenazara
PVPierre Validire
Pierre Validire
This work is devoted to a first exploration of Mueller polarimetric imaging for the detection of residual cancer after neoadjuvant treatment for the rectum. Three samples of colorectal carcinomas treated by radiochemotherapy together with one untreated sample are analyzed ex vivo before fixation in formalin by using a multispectral Mueller polarimetric imaging system operated from 500 to 700 nm. The Mueller images, analyzed using the Lu-Chipmann decomposition, show negligible diattenuation and retardation. The nonirradiated rectum exhibits a variation of depolarization with cancer evolution stage. At all wavelengths on irradiated samples, the contrast between the footprint of the initial tumor and surrounding healthy tissue is found to be much smaller for complete tumor regression than when a residual tumor is present, even at volume fractions of the order of 5%. This high sensitivity is attributed to the modification of stromal collagen induced by the cancer. The depolarization contrast between treated cancer and healthy tissue is found to increase monotonously with the volume fraction of residual cancer in the red part of the spectrum. Polarimetric imaging is a promising technique for detecting short-time small residual cancers, which is valuable information for pathological diagnosis and patient management by clinicians.

1 January 2006 in Optics Express
Verified
Journal Article
Closed access
PDF file
SMS. Manhas
S. Manhas
MSM. K. Swami
M. K. Swami
PBP. Buddhiwant
P. Buddhiwant
NGN. Ghosh
N. Ghosh
PGP. K. Gupta
P. K. Gupta
KSK. Singh
K. Singh
For in vivo determination of optically active (chiral) substances in turbid media, like for example glucose in human tissue, the backscattering geometry is particularly convenient. However, recent polarimetric measurements performed in the backscattering geometry have shown that, in this geometry, the relatively small rotation of the polarization vector arising due to the optical activity of the medium is totally swamped by the much larger changes in the orientation angle of the polarization vector due to scattering. We show that the change in the orientation angle of the polarization vector arises due to the combined effect of linear diattenuation and linear retardance of light scattered at large angles and can be decoupled from the pure optical rotation component using polar decomposition of Mueller matrix. For this purpose, the method developed earlier for polar decomposition of Mueller matrix was extended to incorporate optical rotation in the medium. The validity of this approach for accurate determination of the degree of optical rotation using the Mueller matrix measured from the medium in both forward and backscattering geometry was tested by conducting studies on chiral turbid samples prepared using known concentration of scatterers and glucose molecules.

17 June 2013 in Applied Physics Letters
Verified
Journal Article
Closed access
Tatiana NovikovaTatiana Novikova
Tatiana Novikova
APA. Pierangelo
A. Pierangelo
SMS. Manhas
S. Manhas
ABA. Benali
A. Benali
PVP. Validire
P. Validire
AMA. De Martino
A. De Martino
Experimentally measured spectral Mueller matrix images of ex vivo human colon tissue revealed the contrast enhancement between healthy and cancerous zones of colon specimen compared to unpolarized intensity images. Cancer development starts with abnormal changes which being not yet visible macroscopically may alter the polarization of reflected light. We have shown with experiments and modeling that light scattering by small (sub wavelength) scatterers and light absorption (mainly due to blood hemoglobin) are the key factors for observed polarimetric image contrast. These findings can pave the way for the alternative optical technique for the monitoring and early detection of cancer.

1 January 2006 in Optics Express
Verified
Journal Article
Closed access
PDF file
MSM. K. Swami
M. K. Swami
SMS. Manhas
S. Manhas
PBP. Buddhiwant
P. Buddhiwant
NGN. Ghosh
N. Ghosh
AUA. Uppal
A. Uppal
PGP. K. Gupta
P. K. Gupta
The polarization properties of any medium are completely described by the sixteen element Mueller matrix that relates the polarization parameters of the light incident on the medium to that emerging from it. Measurement of all the elements of the matrix requires a minimum of sixteen measurements involving both linear and circularly polarized light. However, for many diagnostic applications, it would be useful if the polarization parameters can be quantified with linear polarization measurements alone. In this paper, we present a method based on polar decomposition of Mueller matrix for quantification of the polarization parameters of a scattering medium using the nine element (3×3) Mueller matrix that requires linear polarization measurements only. The methodology for decomposition of the 3×3 Mueller matrix is based on the previously developed decomposition process for sixteen element (4×4) Mueller matrix but with an assumption that the depolarization of linearly polarized light due to scattering is independent of the orientation angle of the incident linear polarization vector. Studies conducted on various scattering samples demonstrated that this assumption is valid for a turbid medium like biological tissue where the depolarization of linearly polarized light primarily arises due to the randomization of the field vector’s direction as a result of multiple scattering. For such medium, polar decomposition of 3×3 Mueller matrix can be used to quantify the four independent polarization parameters namely, the linear retardance (δ), the circular retardance (ψ), the linear depolarization coefficient (Δ) and the linear diattenuation (d) with reasonable accuracy. Since this approach requires measurements using linear polarizers only, it considerably simplifies measurement procedure and might find useful applications in tissue diagnosis using the retrieved polarization parameters.

2 February 2015 in Optics Express
Verified
Journal Article
Open access
PDF file
SMSandeep Manhas
Sandeep Manhas
JVJérémy Vizet
Jérémy Vizet
SDStanislas Deby
Stanislas Deby
JVJean-Charles Vanel
Jean-Charles Vanel
PBPaola Boito
Paola Boito
DPDominique Pagnoux
Dominique Pagnoux
A novel technique to measure the full 4 × 4 Mueller matrix of a sample through an optical fiber is proposed, opening the way for endoscopic applications of Mueller polarimetry for biomedical diagnosis. The technique is based on two subsequent Mueller matrices measurements: one for characterizing the fiber only, and another for the assembly of fiber and sample. From this differential measurement, we proved theoretically that the polarimetric properties of the sample can be deduced. The proof of principle was experimentally validated by measuring various polarimetric parameters of known optical components. Images of manufactured and biological samples acquired by using this approach are also presented.