Christin Isaksen

Christin Isaksen

Auto-generated profile, based on publicly available information

Christin Isaksen

Department of Radiology, Regional Hospital of Silkeborg, Silkeborg, Denmark

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 February 2018 in European Heart Journal - Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
LNL Nissen
L Nissen
SWS Winther
S Winther
JWJelmer Westra
Jelmer Westra
JEJ A Ejlersen
J A Ejlersen
CIC Isaksen
C Isaksen
MBM Bøttcher
M Bøttcher
Perfusion scans after coronary computed tomography angiography (CCTA) in patients with suspected coronary artery disease (CAD) may reduce unnecessary invasive coronary angiographies (ICAs). However, the diagnostic accuracy of perfusion scans after primary CCTA is unknown. The aim of this study was to determine the diagnostic accuracy of cardiac magnetic resonance (CMR) and myocardial perfusion scintigraphy (MPS) against ICA with fractional flow reserve (FFR) in patients suspected of CAD by CCTA. Included were consecutive patients (1675) referred to CCTA with symptoms of CAD and low/intermediate risk profile. Patients with suspected CAD based on CCTA were randomized 1:1 to CMR or MPS followed by ICA with FFR. Obstructive CAD was defined as FFR ≤ 0.80 or > 90% diameter stenosis by visual assessment. After initial CCTA, 392 patients (23%) were randomized; 197 to CMR and 195 to MPS. Perfusion scans and ICA were completed in 292 patients (CMR 148, MPS 144). Based on the ICA, 117/292 (40%) patients were classified with CAD. Sensitivity, specificity, negative predictive value (NPV), and positive predictive value (PPV) for CMR were 41%, 95% CI [28–54], 84% [75–91], 62% [45–78], and 68% [58–76], respectively. For the MPS group 36% [24–50], 94% [87–98], 81% [61–93], and 68% [59–76], respectively. Patients with low/intermediate CAD risk and a positive CCTA scan represent a challenge to perfusion techniques indicated by the low sensitivity of both CMR and MPS with FFR as a reference. The mechanisms underlying this discrepancy need further investigation.

26 May 2016 in Trials
Verified
Journal Article
Open access
PDF file
LNLouise Nissen
Louise Nissen
SWSimon Winther
Simon Winther
CIChristin Isaksen
Christin Isaksen
JEJune Anita Ejlersen
June Anita Ejlersen
LBLau Brix
Lau Brix
MBMorten Bøttcher
Morten Bøttcher
Coronary computed tomography angiography (CCTA) is an established method for ruling out coronary artery disease (CAD). Most patients referred for CCTA do not have CAD and only approximately 20–30 % of patients are subsequently referred to further testing by invasive coronary angiography (ICA) or non-invasive perfusion evaluation due to suspected obstructive CAD. In cases with severe calcifications, a discrepancy between CCTA and ICA often occurs, leading to the well-described, low-diagnostic specificity of CCTA. As ICA is cost consuming and involves a risk of complications, an optimized algorithm would be valuable and could decrease the number of ICAs that do not lead to revascularization. The primary objective of the Dan-NICAD study is to determine the diagnostic accuracy of cardiac magnetic resonance imaging (CMRI) and myocardial perfusion scintigraphy (MPS) as secondary tests after a primary CCTA where CAD could not be ruled out. The secondary objective includes an evaluation of the diagnostic precision of an acoustic technology that analyses the sound of coronary blood flow. It may potentially provide better stratification prior to CCTA than clinical risk stratification scores alone. Dan-NICAD is a multi-centre, randomised, cross-sectional trial, which will include approximately 2,000 patients without known CAD, who were referred to CCTA due to a history of symptoms suggestive of CAD and a low-risk to intermediate-risk profile, as evaluated by a cardiologist. Patient interview, sound recordings, and blood samples are obtained in connection with the CCTA. All patients with suspected obstructive CAD by CCTA are randomised to either stress CMRI or stress MPS, followed by ICA with fractional flow reserve (FFR) measurements. Obstructive CAD is defined as an FFR below 0.80 or as high-grade stenosis (>90 % diameter stenosis) by visual assessment. Diagnostic performance is evaluated as sensitivity, specificity, predictive values, likelihood ratios, and C statistics. Enrolment commenced in September 2014 and is expected to be complete in May 2016. Dan-NICAD is designed to assess whether a secondary perfusion examination after CCTA could safely reduce the number of ICAs where revascularization is not required. The results are expected to add knowledge about the optimal algorithm for diagnosing CAD. Clinicaltrials.gov identifier, NCT02264717 . Registered on 26 September 2014.

1 September 2020 in Radiology
Verified
Journal Article
Closed access
JTJosephine Therkildsen
Josephine Therkildsen
LNLouise Nissen
Louise Nissen
HJHanne Skou Joergensen
Hanne Skou Joergensen
JTJesper Thygesen
Jesper Thygesen
PIPer Ivarsen
Per Ivarsen
SWSimon Winther
Simon Winther
Cardiac CT can be used to evaluate fracture rate by assessing the bone mineral density of thoracic vertebrae. Background Osteoporosis is a prevalent, under-diagnosed, and treatable disease associated with increased fracture risk. Bone mineral density (BMD) derived from cardiac CT may be used to determine f...

1 April 2020 in JACC: Cardiovascular Imaging
Verified
Journal Article
Open access
NSNiels Peter Rønnow Sand
Niels Peter Rønnow Sand
LNLouise Nissen
Louise Nissen
SWSimon Winther
Simon Winther
SPSteffen E. Petersen
Steffen E. Petersen
JWJelmer Westra
Jelmer Westra
MBMorten Bøttcher
Morten Bøttcher
This study was designed to compare head-to-head fractional flow reserve (FFR) derived from coronary computed tomography angiography (CTA) (FFRCT) and cardiac magnetic resonance (CMR) stress perfusion imaging for prediction of standard-of-care-guided coronary revascularization in patients with stable chest pain and obstructive coronary artery disease by coronary CTA. FFRCT is a novel modality for noninvasive functional testing. The clinical utility of FFRCT compared to CMR stress perfusion imaging in symptomatic patients with coronary artery disease is unknown. Prospective study of patients (n = 110) with stable angina pectoris and 1 or more coronary stenosis ≥50% by coronary CTA. All patients underwent invasive coronary angiography. Revascularization was FFR-guided in stenoses ranging from 30% to 90%. FFRCT ≤0.80 in 1 or more coronary artery or a reversible perfusion defect (≥2 segments) by CMR categorized patients with ischemia. FFRCT and CMR were analyzed by core laboratories blinded for patient management. A total of 38 patients (35%) underwent revascularization. Per-patient diagnostic performance for identifying standard-of-care-guided revascularization, (95% confidence interval) yielded a sensitivity of 97% (86% to 100%) for FFRCT versus 47% (31% to 64%) for CMR, p < 0.001; corresponding specificity was 42% (30% to 54%) versus 88% (78% to 94%), p < 0.001; negative predictive value of 97% (91% to 100%) versus 76% (67% to 85%), p < 0.05; positive predictive value of 47% (36% to 58%) versus 67% (49% to 84%), p < 0.05; and accuracy of 61% (51% to 70%) versus 74% (64% to 82%), p > 0.05, respectively. In patients with stable chest pain referred to invasive coronary angiography based on coronary CTA, FFRCT and CMR yielded similar overall diagnostic accuracy. Sensitivity for prediction of revascularization was highest for FFRCT, whereas specificity was highest for CMR.

1 September 2019 in American Heart Journal
Verified
Journal Article
Open access
LRLaust Dupont Rasmussen
Laust Dupont Rasmussen
SWSimon Winther
Simon Winther
JWJelmer Westra
Jelmer Westra
CIChristin Isaksen
Christin Isaksen
JEJune Anita Ejlersen
June Anita Ejlersen
MBMorten Böttcher
Morten Böttcher
Coronary computed tomography angiography (CTA) is the preferred primary diagnostic modality when examining patients with low to intermediate pre-test probability of coronary artery disease (CAD). Only 20-30% of these have potentially obstructive CAD. Because of the relatively poor positive predictive value of coronary CTA, unnecessary invasive coronary angiographies (ICAs) are conducted with the costs and risks associated with the procedure. Hence, an optimized diagnostic CAD algorithm may reduce the numbers of ICAs not followed by revascularization. The Dan-NICAD 2 study has 3 equivalent main aims: (1) To examine the diagnostic precision of a sound-based diagnostic algorithm, The CADScor®System (Acarix A/S, Denmark), in patients with a low to intermediate pre-test risk of CAD referred to a primary examination by coronary CTA. We hypothesize that the CADScor®System provides better stratification prior to coronary CTA than clinical risk stratification scores alone. (2) To compare the diagnostic accuracy of 3T cardiac magnetic resonance imaging (3T CMRI), 82rubidium positron emission tomography (82Rb-PET), and CT-derived fractional flow reserve (FFRCT) in patients where obstructive CAD cannot be ruled out by coronary CTA using ICA fractional flow reserve (FFR) as reference standard. (3) To compare the diagnostic performance of quantitative flow ratio (QFR) and ICA-FFR in patients with low to intermediate pre-test probability of CAD using 82Rb-PET as reference standard. Dan-NICAD 2 is a prospective, multicenter, cross-sectional study including approximately 2,000 patients with low to intermediate pre-test probability of CAD and without previous history of CAD. Patients are referred to coronary CTA because of symptoms suggestive of CAD, as evaluated by a cardiologist. Patient interviews, sound recordings, and blood samples are obtained in connection with the coronary CTA. If coronary CTA does not rule out obstructive CAD, patients will be examined by 3T CMRI 82Rb-PET, FFRCT, ICA, and FFR. Reference standard is ICA-FFR. Obstructive CAD is defined as an FFR ≤0.80 or as high-grade stenosis (>90% diameter stenosis) by visual assessment. Diagnostic performance will be evaluated as sensitivity, specificity, predictive values, likelihood ratios, calibration, and discrimination. Enrolment started January 2018 and is expected to be completed by June 2020. Patients are followed for 10 years after inclusion. The results of the Dan-NICAD 2 study are expected to contribute to the improvement of diagnostic strategies for patients suspected of CAD in 3 different steps: risk stratification prior to coronary CTA, diagnostic strategy after coronary CTA, and invasive wireless QFR analysis as an alternative to ICA-FFR.

19 November 2019 in The International Journal of Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
MSMartin Sejr-Hansen
Martin Sejr-Hansen
JWJelmer Westra
Jelmer Westra
SWSimon Winther
Simon Winther
STShengxian Tu
Shengxian Tu
LNLouise Nissen
Louise Nissen
NHNiels Ramsing Holm
Niels Ramsing Holm
Quantitative flow ratio (QFR) and fractional flow reserve (FFR) have not yet been compared head to head with perfusion imaging as reference for myocardial ischemia. We aimed to compare the diagnostic accuracy of QFR and FFR with myocardial perfusion scintigraphy (MPS) or cardiovascular magnetic resonance (CMR) as reference. This study is a predefined post hoc analysis of the Dan-NICAD study (NCT02264717). Patients with suspected coronary artery disease by coronary computed tomography angiography (CCTA) were randomized 1:1 to MPS or CMR and were referred to invasive coronary angiography with FFR and predefined QFR assessment. Paired data with FFR, QFR and MPS or CMR were available for 232 vessels with stenosis in 176 patients. Perfusion defects were detected in 57 vessel territories (25%). For QFR and FFR the diagnostic accuracy was 61% and 57% (p = 0.18) and area under the receiver operating curve was 0.64 vs. 0.58 (p = 0.22). Stenoses with absolute indication for stenting due to diameter stenosis > 90% by visual estimate were not classified as significant by either QFR or MPS/CMR in 21% (7 of 34) of cases. The diagnostic performance of QFR and FFR was similar but modest with MPS or CMR as reference. Comparable performance levels for QFR and FFR are encouraging for this pressure wire-free diagnostic method.