Jhakelin Reyes Vasquez

Jhakelin Reyes Vasquez

Auto-generated profile, based on publicly available information

Jhakelin Reyes Vasquez

Conservación Amazónica-ACCA Field Projects International Wildlife Alliance In Situ Laboratories Imperial College London Universidad Austral de Chile Universidad Nacional Mayor de San Marcos Sn Diego Zoo Wildlif Alliance San Diego Zoo

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 March 2019 in Andrologia
Verified
Journal Article
Closed access
PDF file
MVMartha E Valdivia
Martha E Valdivia
Sergio Miguel Castaneda ZegarraSergio Miguel Castaneda Zegarra
Sergio Miguel Castaneda Zegarra
GSGloria Levano Sanchez
Gloria Levano Sanchez
JLJorge Lazo
Jorge Lazo
JRJhakelin Reyes
Jhakelin Reyes
Gustavo F. GonzalesGustavo F. Gonzales
Gustavo F. Gonzales

21 March 2019 in Andrologia
Verified
Journal Article
Closed access
PDF file
MVMartha E Valdivia
Martha E Valdivia
JRJhakelin Reyes
Jhakelin Reyes
ZBZezé Bravo
Zezé Bravo
CCChristian Cancho
Christian Cancho
Sergio Miguel Castaneda ZegarraSergio Miguel Castaneda Zegarra
Sergio Miguel Castaneda Zegarra
GGGustavo F. Gonzales
Gustavo F. Gonzales

17 October 2023
Verified
Preprint
Open access
PDF file
JVJhakelin Reyes Vasquez
Jhakelin Reyes Vasquez
PSP. Sánchez-Vendizú
P. Sánchez-Vendizú
KVKristina N Vsevolodova
Kristina N Vsevolodova
GEGideon Erkenswick
Gideon Erkenswick
MWMrinalini Watsa
Mrinalini Watsa
This protocol is an automated pipeline to clean a plate of extracted DNA using SPRI bead cleanup. It is functional for both. It is typically used to clean up a portion of extracted DNA which has suspected impurities capable of affecting downstream PCR or sequencing protocols. This is often a side effect of extraction by MagBeads with no spin-column based purifications. We have found this protocol to be effective on DNA extracted from blood, biopsy and feces in a wide range of Neotropical vertebrates. This protocol was developed and optimised for the following: Platform: Opentrons OT-2 automated pipetting robot Kit: Ampure beads and home-brewed bead solutions Tips Used: 5 boxes (2 x 200uL Opentrons Filtered Tip boxes and 3 x 20uL Opentrons Filtered Tip boxes) Number of samples: 96 V2 - This is a new version of the original protocol modified as follows: We include an updated version of the protocol python file, which is optimized to work on version 6.3.1. Note Version 1 protocol's file is likely to glitch, so please use this file instead. To assist with implementing this new protocol in your lab, we also include a simplified version of the python file for a test water run in Section 2. The test reduces incubation times, and works for samples in multiples of 8, so you can test only 8 for a quicker version of the protocol. Error correction: OT-2 Single Channel Electronic Pipette P20 was changed to OT-2 8-Channel Electronic Pipette P20. Starting sample clean up volume was changed to 25uL from 15uL and all subsequent calculations and descriptions were changed to reflect this. Note: You can alter these volumes easily as well. Bead ratio was changed to 1.5X and all subsequent calculations and descriptions were changed to reflect this.Note: this can also be altered to match your specific use case.

22 September 2023
Verified
Preprint
Open access
PDF file
JVJhakelin Reyes Vasquez
Jhakelin Reyes Vasquez
PSP. Sánchez-Vendizú
P. Sánchez-Vendizú
TTThalía Thalia.Silvestre
Thalía Thalia.Silvestre
GEGideon Erkenswick
Gideon Erkenswick
ASAlexandra Sacco
Alexandra Sacco
MWMrinalini Watsa
Mrinalini Watsa
This protocol is a general automated pipeline to prepare mastermix at the plate level in a sterile way. The protocol volumes can be edited, as can sample numbers, to change the scale of the operation and optimise it to fit any end-point PCR. This protocol was developed and optimised for the following: Platform: Opentrons OT-2 automated pipetting robot Tested with software version 6.3.1 Tips Used: 1 box and 1 column of 20uL filtered Opentrons Tips Number of samples: 91 samples and 5 controls in a 96 well plate Important: In an ideal situation, there would be two OT-2 robots involved in this process: the first to prepare sterile reagents and make and aliquot the mastermix, and the second to add the template. In the absence of this facility, we have developed a means of keeping each ingredient on the deck singly, rather than having all ingredients open on the deck at once. So please take note of the protocol pauses in built to replace each ingredient with the next. In this way, no two ingredients are open inside the OT2 hood at the same time. Python File Version 2.2.

8 December 2022
Verified
Preprint
Open access
PDF file
JVJhakelin Reyes Vasquez
Jhakelin Reyes Vasquez
PSP. Sánchez-Vendizú
P. Sánchez-Vendizú
MWMrinalini Watsa
Mrinalini Watsa
GEGideon Erkenswick
Gideon Erkenswick
This protocol is an automated pipeline to clean a plate of extracted DNA using SPRI bead cleanup. It is functional for both. It is typically used to clean up a portion of extracted DNA which has suspected impurities capable of affecting downstream PCR or sequencing protocols. This is often a side effect of extraction by magbeads with no spin-column based purifications. We have found this protocol to be effective on DNA extracted from blood, biopsy and feces in a wide range of Neotropical vertebrates. This protocol was developed and optimised for the following: Platform: Opentrons OT-2 automated pipetting robot Kit: Ampure beads and home-brewed bead solutions Tips Used: 5 boxes (2 x 200uL Opentrons Filtered Tip boxes and 3 x 20uL Opentrons Filtered Tip boxes) Number of samples: 96