Representative Publications

View All Publications
21 September 2018 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
STShengzhen Tao
Shengzhen Tao
KRKishore Rajendran
Kishore Rajendran
CMCynthia H McCollough
Cynthia H McCollough
SLShuai Leng
Shuai Leng
Dual- or multi-energy CT, also known as spectral CT, obtains x-ray attenuation measurements at two or more energy spectra, allowing quantification of materials with different compositions. This process is known as material decomposition, which is the basis for a number of spectral CT applications. The conventional image-domain basis material decomposition is based on a least-squares fitting between the underlying material-specific images and the measured source spectral CT images (i.e. energy-bin or energy-threshold CT images), and a non-iterative solution based on matrix inversion can be derived for this process. However, due to its ill-conditioned nature, the material decomposition process is intrinsically susceptible to noise amplification. Hence, material-specific images can be contaminated by the presence of strong noise, which compromises the conspicuity of small objects, and hinders the delineation of anatomical regions of interest and associated pathology. In this work, we describe an image domain material decomposition framework with prior knowledge aware iterative denoising (MD-PKAID). The proposed framework exploits the structural redundancy between the individual material-specific images and the source spectral CT images to retain structural details in denoised material-specific images. It directly treats material decomposition as a regularized optimization problem with spectral CT images measured with different energy spectra as inputs. Phantom, in vivo animal and human data were acquired on a research whole-body photon-counting-detector-based CT system and a dual-source, dual-energy CT system to test the proposed method. The phantom results show that the proposed MD-PKAID can reduce the root-mean-square-error of basis material quantification by 75% compared to the standard material decomposition based on matrix inversion, while preserving structural details and image resolution in the material-specific images. The initial in vivo results demonstrate that the proposed method can improve delineation of small vasculature features in iodine-specific images while reducing image noise.

21 June 2017 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
PWPaul T. Weavers
Paul T. Weavers
STShengzhen Tao
Shengzhen Tao
JTJoshua D. Trzasko
Joshua D. Trzasko
LFLouis M. Frigo
Louis M. Frigo
YSYunhong Shu
Yunhong Shu
MBMatt A. Bernstein
Matt A. Bernstein

28 December 2023 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
LOLela Okromelidze
Lela Okromelidze
VPVishal Patel
Vishal Patel
RSRahul B. Singh
Rahul B. Singh
ACAlfonso S. Lopez Chiriboga
Alfonso S. Lopez Chiriboga
STShengzhen Tao
Shengzhen Tao
EMErik Middlebrooks
Erik Middlebrooks
BACKGROUND AND PURPOSE: An early and accurate diagnosis of multiple sclerosis remains challenging in clinical neurology. Established diagnostic methods have less than desirable sensitivity and specificity. An accurate, noninvasive diagnostic test for MS could have a major impact on diagnostic criteria. We compared the frequency of detection of the central vein sign (CVS) in white matter lesions of MS and controls on 7T T2*-weighted and SWI to 3T SWI. Additionally, we assessed the diagnostic performance of 7T T2*, 7T SWI, and 3T SWI for MS. MATERIALS AND METHODS: A retrospective case-control study was performed of patients with MS having both 7T MRI and 3T MRI. A control group of patients without MS was selected. Diagnosis of MS was established by board-certified neurologists with fellowship training in autoimmune neurology in line with the 2017 McDonald criteria. Percentage of lesions with a CVS was blindly measured for each technique. Diagnostic performance was computed by sensitivity, specificity, and positive and negative likelihood ratios (LRs). RESULTS: Sixty-one patients with MS (903 lesions) and 39 controls (1088 lesions) were included. 7T T2* showed significantly more CVS (87%) than both 7T SWI (73%) and 3T SWI (31%) (all P < .001). CVS was identified in the control group in ≤6% of lesions on all sequences. Using a threshold of >40% of lesions with CVS on 7T T2* and >15% on 7T SWI, both sequences had an accuracy = 100%, sensitivity = 100%, specificity = 100%, infinite positive LR, and zero negative LR. Using an optimal threshold of >12%, 3T SWI had an accuracy = 96.0%, sensitivity = 93.4%, specificity = 100%, infinite positive LR, and negative LR = 0.066. CONCLUSIONS: 7T MRI had 100% sensitivity and specificity for the diagnosis of MS and is superior to 3T. Future revisions to MS diagnostic criteria may consider recommendations for 7T MRI and inclusion of CVS as a biomarker.

31 May 2019 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
ATAshley Tao
Ashley Tao
RHRichard Huang
Richard Huang
STShengzhen Tao
Shengzhen Tao
GMGregory J Michalak
Gregory J Michalak
CMCynthia H McCollough
Cynthia H McCollough
SLShuai Leng
Shuai Leng
Photon counting detectors (PCD) can provide spectral information to enable iodine quantification through multi-energy imaging but performance is limited by current PCD technology. The purpose of this work is to evaluate iodine quantification in a phantom study using dual-source PCD-CT (DS-PCD-CT), and compare to single-source (SS)-PCD-CT and traditional DS energy integrating detector (EID)-based dual-energy CT. A multi-energy CT phantom with iodine inserts (0 to 15 mg ml −1 concentration) was imaged on a research SS-PCD-CT scanner (CTDI vol = 18 mGy). A DS-PCD-CT was emulated by acquiring two sequential scans (CTDI vol = 9 mGy each) using tube potentials: 140 kVp/80 kVp, 140 kVp/100 kVp and 140 kVp/120 kVp. For each kVp, 1 or 2 energy bins were reconstructed to achieve either dual-energy or quadruple energy CT. In addition to these energy combinations, a Sn filter was used for the high tube potential (140 kVp) of each kVp pair. For comparison, the same phantom was also scanned on a commercially available DS-EID-CT with matched radiation dose (CTDI vol = 18 mGy). Material decomposition was performed in image space using a standard least-squares based approach to generate iodine and water-specific images. The root-mean-square-error (RMSE) measured over each insert from the iodine image was used to determine iodine accuracy. The iodine RMSE from SS-PCD (140 kVp with 2 energy bins) was 2.72 mg ml −1 . The use of a DS configuration with 1 energy bin per kVp (140 kVp/80 kVp) resulted in a RMSE of 2.29 mg ml −1 . Two energy bins per kVp further reduced iodine RMSE to 1.83 mg ml −1 . The addition of a Sn filter to the latter quadruple energy mode reduced RMSE to 1.48 mg ml −1 . RMSE for DS-PCD-CT (2 energy bins per kVp) decreased by 1.3% (Sn140 kVp/80 kVp) and 15% (Sn140 kVp/100 kVp) as compared to DS-EID-CT. DS-PCD-CT with a Sn filter improved iodine quantification as compared to both SS-PCD-CT and DS-EID-CT.

1 May 2019 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
STShengzhen Tao
Shengzhen Tao
KRKishore Rajendran
Kishore Rajendran
WZWei Zhou
Wei Zhou
JFJoel G Fletcher
Joel G Fletcher
CMCynthia H McCollough
Cynthia H McCollough
SLShuai Leng
Shuai Leng
Multi-energy CT acquires simultaneous multiple x-ray attenuation measurements from different energy spectra which facilitates the computation of virtual monoenergetic images (VMI) at a specific photon energy (keV). Since the contrast between iodine attenuation and the attenuation of surrounding soft tissues increases at lower x-ray energies, VMIs in the range of 40–70 keV can be used to improve iodine visualization. However, at lower energy levels, image noise in VMIs is substantially increased, which counteracts the benefits from the increased iodine contrast, resulting in a decreased iodine contrast-to-noise ratio (CNR). There exists considerable data redundancy between multi-energy CT images created from the same acquisition. Similarly, a substantial spatio-spectral data redundancy exists between multi-energy CT images and the corresponding VMIs. In this work, we develop a denoising framework that exploits this data redundancy to improve iodine CNR in the VMIs. We accomplish this by applying prior-knowledge-aware iterative denoising to low-energy VMIs; we refer to the denoised images as mono-PKAID images. The proposed framework was evaluated using phantom and in vivo data acquired on a research whole-body photon-counting-detector CT, as well as using data from a commercial dual-source dual-energy CT system. The results of phantom experiments show that the proposed framework can preserve image resolution and noise texture compared to the original VMIs, while reducing noise to improve iodine CNR. Quantitative measurements show that the iodine CNR of 50 keV VMI is improved by 1.8-fold using the proposed method, relative to the VMI produced using commercial software (Mono+). With mono-PKAID, VMIs at lower keV take full advantage of higher iodine contrast without substantially increasing image noise. These observations were confirmed using patient data sets, which demonstrated that mono-PKAID reduced image noise, improved CNR in anatomical regions with iodine perfusion by 1.8-fold, and potentially enhanced the visibility of focal liver lesions.

21 August 2020 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
STShengzhen Tao
Shengzhen Tao
JMJeffrey F Marsh
Jeffrey F Marsh
ATAshley Tao
Ashley Tao
GMGreg J Michalak
Greg J Michalak
KRKishore Rajendran
Kishore Rajendran
SLShuai Leng
Shuai Leng
Multi-energy CT imaging of large patients with conventional dual-energy (DE)-CT using an energy-integrating-detector (EID) is challenging due to photon starvation-induced image artifacts, especially in lower tube potential (80–100 kV) images. Here, we performed phantom experiments to investigate the performance of DECT for morbidly obese patients, using an iodine and water material decomposition task as an example, on an emulated dual-source (DS)-photon-counting-detector (PCD)-CT, and compared its performance with a clinical DS-EID-CT. An abdominal CT phantom with iodine inserts of different concentrations was wrapped with tissue-equivalent gel layers to emulate a large patient (50 cm lateral size). The phantom was scanned on a research whole-body single-source (SS)-PCD-CT (140 kV tube potential), a DS-PCD-CT (100/Sn140 kV; Sn140 indicates 140 kV with Sn filter), and a clinical DS-EID-CT (100/Sn140 kV) with the same radiation dose. Phantom scans were repeated five times on each system. The DS-PCD-CT acquisition was emulated by scanning twice on the SS-PCD-CT using different tube potentials. The multi-energy CT images acquired on each system were then reconstructed, and iodine- and water-specific images were generated using material decomposition. The root-mean-square-error (RMSE) between true and measured iodine concentrations were calculated for each system and compared. The images acquired on the DS-EID-CT showed severe artifacts, including ringing, reduced uniformity, and photon starvation artifacts, especially for low-energy images. These were largely reduced in DS-PCD-CT images. The CT number difference that was measured using regions-of-interest across field-of-view were reduced from 20.3 ± 0.9 (DS-EID-CT) to 2.5 ± 0.4 HU on DS-PCD-CT, showing improved image uniformity using DS-PCD-CT. Iodine RMSE was reduced from 3.42 ± 0.03 mg ml −1 (SS-PCD-CT) and 2.90 ± 0.03 mg ml −1 (DS-EID-CT) to 2.39 ± 0.05 mg ml −1 using DS-PCD-CT. DS-PCD-CT out-performed a clinical DS-EID-CT for iodine and water-based material decomposition on phantom emulating obese patients by reducing image artifacts and improving iodine quantification (RMSE reduced by 20%). With DS-PCD-CT, multi-energy CT can be performed on large patients that cannot be accommodated with current DECT.