Michael A. Bruno

Michael A. Bruno

Auto-generated profile, based on publicly available information

Michael A. Bruno

Department of Radiology , Penn State Health Milton S. Hershey Medical Center , Hershey , PA , USA

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2015 in RadioGraphics
Verified
Journal Article
Closed access
MBMichael A. Bruno
Michael A. Bruno
EWEric A. Walker
Eric A. Walker
HAHani H. Abujudeh
Hani H. Abujudeh
Radiologists’ errors frequently contribute to missed and delayed diagnoses; understanding these errors and their underlying causes is an urgent priority to develop effective strategies for error reduction and prevent patient harm. Arriving at a medical diagnosis is a highly complex process that is extremely error prone. Missed or delayed diagnoses often lead to patient harm and missed opportunities for treatment. Since medical imaging is a major contributor to the overall diagnostic process, it is also a major potential source of diagnostic error. Although some diagnoses may be missed because of the technical or physical limitations of the imaging modality, including image resolution, intrinsic or extrinsic contrast, and signal-to-noise ratio, most missed radiologic diagnoses are attributable to image interpretation errors by radiologists. Radiologic interpretation cannot be mechanized or automated; it is a human enterprise based on complex psychophysiologic and cognitive processes and is itself subject to a wide variety of error types, including perceptual errors (those in which an important abnormality is simply not seen on the images) and cognitive errors (those in which the abnormality is visually detected but the meaning or im...

1 August 2022 in Radiology
Verified
Journal Article
Closed access
Robert G AlexanderRobert G Alexander
Robert G Alexander
SWStephen Waite
Stephen Waite
MBMichael A. Bruno
Michael A. Bruno
EKElizabeth Krupinski
Elizabeth Krupinski
LBLeonard Berlin
Leonard Berlin
SMSusana Martinez-Conde
Susana Martinez-Conde
Although it is almost certain that increased workloads, faster speeds, and prolonged shifts will at some point decrease interpretive accuracy, there is currently insufficient evidence to determine ... Research has not yet quantified the effects of workload or duty hours on the accuracy of radiologists. With the exception of a brief reduction in imaging studies during the 2020 peak of the COVID-1...

1 September 2014 in Journal of the American College of Radiology
Verified
Journal Article
Closed access
MBMichael A. Bruno
Michael A. Bruno
JPJonelle M. Petscavage-Thomas
Jonelle M. Petscavage-Thomas
MMMichael J. Mohr
Michael J. Mohr
SBSigall K. Bell
Sigall K. Bell
SBStephen D. Brown
Stephen D. Brown

22 May 2025 in NEJM AI
Verified
Journal Article
Closed access
MBMichael H. Bernstein
Michael H. Bernstein
BSBrian Sheppard
Brian Sheppard
MBMichael A. Bruno
Michael A. Bruno
PLParker S. Lay
Parker S. Lay
GBGrayson L. Baird
Grayson L. Baird

1 December 2018 in Radiology
Verified
Journal Article
Closed access
MBMichael A. Bruno
Michael A. Bruno
JDJames R. Duncan
James R. Duncan
ABAndrew J. Bierhals
Andrew J. Bierhals
RTRafel Tappouni
Rafel Tappouni
Academic medical centers have long relied on radiology residents to provide after-hours coverage, which means that they essentially function with autonomy. In this approach, attending radiologist review of resident interpretations occurs the following morning, often by subspecialist faculty. In recent years, however, this traditional coverage model in academic radiology departments has been challenged by an alternative model, the 24-hour attending radiologist coverage. Proponents of this new model seek to improve patient care after hours by increasing report accuracy and the speed with which the report is finalized. In this article, we review the traditional and the 24-hour attending radiologist coverage models. We summarize previous studies that indicate that resident overnight error rates are sufficiently low so that changing to an overnight attending model may not necessarily provide a meaningful increase in report accuracy. Whereas some centers completely replaced overnight residents, we note that most centers use a hybrid model, and overnight residents work alongside supervising attending radiologists, much as they do during the day. Even in this hybrid model, universal double reading and subspecialist final review, typical features of the traditional autonomous resident coverage model, are generally sacrificed. Because of this, changing from resident coverage to coverage by an attending radiologist that is 24 hours/day, 7 days/week may actually have detrimental effects to patient safety and quality of care provided. Changing to an overnight attending radiologist model may also have negative effects on the quality of radiology resident training, and it significantly increases cost.

28 July 2017 in Diagnosis
Verified
Journal Article
Closed access
PDF file
MBMichael A. Bruno
Michael A. Bruno
Radiologists practice in an environment of extraordinarily high uncertainty, which results partly from the high variability of the physical and technical aspects of imaging, partly from the inherent limitations in the diagnostic power of the various imaging modalities, and partly from the complex visual-perceptual and cognitive processes involved in image interpretation. This paper reviews the high level of uncertainty inherent to the process of radiological imaging and image interpretation vis-à-vis the issue of radiological interpretive error, in order to highlight the considerable degree of overlap that exists between these. The scope of radiological error, its many potential causes and various error-reduction strategies in radiology are also reviewed.