Francisco Fernandez-Trillo

Francisco Fernandez-Trillo

Auto-generated profile, based on publicly available information

Francisco Fernandez-Trillo

CICA – Centro Interdisciplinar de Química e Bioloxía and Departamento de Química, Facultade de Ciencias, Universidade da Coruña, 15071 A, Coruña, Spain

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 May 2020 in Nature Reviews Chemistry
Verified
Journal Article
Closed access
PDF file
TLThomas Leigh
Thomas Leigh
PFPaco Fernandez-Trillo
Paco Fernandez-Trillo

13 September 2011 in Pharmaceutical Research
Verified
Journal Article
Closed access
PDF file
ELEnrique Lallana
Enrique Lallana
Ana Sousa-HervesAna Sousa-Herves
Ana Sousa-Herves
FFFrancisco Fernandez-Trillo
Francisco Fernandez-Trillo
RRRicardo Riguera
Ricardo Riguera
EFEduardo Fernandez-Megia
Eduardo Fernandez-Megia

11 May 2014 in Nature Materials
Verified
Journal Article
Open access
PDF file
EME. Peter Magennis
E. Peter Magennis
FFFrancisco Fernandez-Trillo
Francisco Fernandez-Trillo
CSCheng Sui
Cheng Sui
SSSebastian Guy Spain
Sebastian Guy Spain
DBDavid J. Bradshaw
David J. Bradshaw
CACameron Alexander
Cameron Alexander
The detection and inactivation of pathogenic strains of bacteria continues to be an important therapeutic goal. Hence, there is a need for materials that can bind selectively to specific microorganisms for diagnostic or anti-infective applications, but that can be formed from simple and inexpensive building blocks. Here, we exploit bacterial redox systems to induce a copper-mediated radical polymerization of synthetic monomers at cell surfaces, generating polymers in situ that bind strongly to the microorganisms that produced them. This ‘bacteria-instructed synthesis’ can be carried out with a variety of microbial strains, and we show that the polymers produced are self-selective binding agents for the ‘instructing’ cell types. We further expand on the bacterial redox chemistries to ‘click’ fluorescent reporters onto polymers directly at the surfaces of a range of clinical isolate strains, allowing rapid, facile and simultaneous binding and visualization of pathogens.

1 August 2016 in European Polymer Journal
Verified
Journal Article
Open access
IIIgnacio Insua
Ignacio Insua
AWAndrew Wilkinson
Andrew Wilkinson
FFFrancisco Fernandez-Trillo
Francisco Fernandez-Trillo
Oppositely charged polyions can self-assemble in solution to form colloidal polyion complex (PIC) particles. Such nanomaterials can be loaded with charged therapeutics such as DNA, drugs or probes for application as novel nanomedicines and chemical sensors to detect disease markers. A comprehensive discussion of the factors affecting PIC particle self-assembly and their response to physical and chemical stimuli in solution is described herein. Finally, a collection of key examples of polyionic nanoparticles for biomedical applications is discussed to illustrate their behaviour and demonstrate the potential of PIC nanoparticles in medicine.

25 January 2012 in Pharmaceutical Research
Verified
Journal Article
Closed access
PDF file
ELEnrique Lallana
Enrique Lallana
FFFrancisco Fernandez-Trillo
Francisco Fernandez-Trillo
Ana Sousa-HervesAna Sousa-Herves
Ana Sousa-Herves
RRRicardo Riguera
Ricardo Riguera
EFEduardo Fernandez-Megia
Eduardo Fernandez-Megia

11 August 2015 in The Analyst
Verified
Journal Article
Closed access
PDF file
JMJavier Monzó
Javier Monzó
IIIgnacio Insua
Ignacio Insua
FFFrancisco Fernandez-Trillo
Francisco Fernandez-Trillo
Paramaconi RodriguezParamaconi Rodriguez
Paramaconi Rodriguez
Electrochemical sensors are powerful tools widely used in industrial, environmental and medical applications. The versatility of electrochemical methods allows for the investigation of chemical composition in real time and in situ. Electrochemical detection of specific biological molecules is a powerful means for detecting disease-related markers. In the last 10 years, highly-sensitive and specific methods have been developed to detect waterborne and foodborne pathogens. In this review, we classify the different electrochemical techniques used for the qualitative and quantitative detection of pathogens. The robustness of electrochemical methods allows for accurate detection even in heterogeneous and impure samples. We present a fundamental description of the three major electrochemical sensing methods used in the detection of pathogens and the advantages and disadvantages of each of these methods. In each section, we highlight recent breakthroughs, including the utilisation of microfluidics, immunomagnetic separation and multiplexing for the detection of multiple pathogens in a single device. We also include recent studies describing new strategies for the design of future immunosensing systems and protocols. The high sensitivity and selectivity, together with the portability and the cost-effectiveness of the instrumentation, enhances the demand for further development in the electrochemical detection of microbes.