Chani Park

Chani Park

Auto-generated profile, based on publicly available information

Chani Park

Department of Electronic Engineering Kwangwoon University Seoul 139–701 Republic of Korea

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 August 2021 in Advanced Functional Materials
Verified
Journal Article
Closed access
PDF file
SRS M Sohel Rana
S M Sohel Rana
AZAbu Zahed
Abu Zahed
MRM. Toyabur Rahman
M. Toyabur Rahman
Md SALAUDDINMd SALAUDDIN
Md SALAUDDIN
SLSang Hyun Lee
Sang Hyun Lee
JPJae Yeong Park
Jae Yeong Park

23 April 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
CPChani Park
Chani Park
HYHyosang Yoon
Hyosang Yoon
AZAbu Zahed
Abu Zahed
SZShipeng Zhang
Shipeng Zhang
SYSanghyuk Yoon
Sanghyuk Yoon
JPJae Yeong Park
Jae Yeong Park
In this work, a highly stable Ca 2+ ion-selective sensor was successfully developed by depositing a poly(3,4-ethylenedioxythiophene): poly(styrene-sulfonate) (PEDOT:PSS) layer on top of a carbon paste electrode as an ion-electron transducing layer. The PEDOT:PSS was treated by a co-solvent of ethylene glycol (EG) using the bath-sonication technique to enhance electrical and electrochemical characteristics, and finally coated with Ca 2+ ion-selective membrane cocktail. The developed Ca 2+ ion-selective electrode (Ca 2+ -ISE) showed excellent electrochemical properties by much-improved charge transfer kinetics with remarkable electric conductivity. The fabricated Ca 2+ -ISE exhibited an excellent sensitivity of 37.7 mV/decade (n = 4) in the range from 10 −4 to 10 −1 M with a rapid response (< 20 seconds). Moreover, the EG-treated PEDOT:PSS (PEDOT:PSS-EG) based ISE showed negligible responses for primary interfering ions of human biofluid samples, proving significant potential selectivity. Furthermore, the negligible drift of open circuit potential ( $2.78~ { \mu }\text{V}$ /s) proved the stability of the PEDOT:PSS-EG compared to pristine PEDOT:PSS( $10.63~{ \mu }\text{V}$ /s) based ISE. Based on these analyses, it can be expected that the organic solvent treatment on PEDOT:PSS will pave the way for long-term monitoring of other biochemical compounds.

20 June 2021
Verified
Conference Paper
Closed access
SZShipeng Zhang
Shipeng Zhang
Ashok ChhetryAshok Chhetry
Ashok Chhetry
SSSudeep Sharma
Sudeep Sharma
CPChani Park
Chani Park
JPJae Yeong Park
Jae Yeong Park
It is highly demanded to develop flexible strain sensors with high sensitivity, a wide working range, and excellent reliability. We newly applied 3,4-ethylene dioxythiophene (EDOT) in-situ polymerization self-assembly on MXene-Ti 3 C 2 T x flakes in an aqueous solution in order to simultaneously improve both the sensitivity and working range of the strain sensor patch. MXene-Ti 3 C 2 T x @EDOT was uniformly deposited on the laser-induced graphene (LIG) embedded styrene ethylene butylene styrene (SEBS) stretchable substrate by electrophoretic deposition without any oxidants. The as-fabricated sensor can detect minute to large deformations with high GF up to 2075, large strain range (>28%), and excellent reliability (>20000 cycles). A flexible battery-free near field communication (NFC) wireless system was developed and transmit measurements to a smartphone.