Byeong Gwan Bhang

Byeong Gwan Bhang

Auto-generated profile, based on publicly available information

Byeong Gwan Bhang

Next Generation Photovoltaic Module and Power System Research Center, Konkuk University, Seoul, South Korea

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 February 2019 in IEEE Journal of Photovoltaics
Verified
Journal Article
Open access
GKGyuGwang Kim
GyuGwang Kim
JCJin Ho Choi
Jin Ho Choi
SPSo Young Park
So Young Park
BBByeong Gwan Bhang
Byeong Gwan Bhang
WNWoo Jun Nam
Woo Jun Nam
HYUNG KEUN AHNHYUNG KEUN AHN
HYUNG KEUN AHN
With increasing installations of photovoltaic (PV) systems, interest in power forecasting has also increased. Inaccurate forecasts would result in substantial economic losses and system reliability issues. The correlation between weather variables and PV power is critical to ensure the efficient use of energy in PV systems. A key step toward accurate power forecasting is estimating the output from a PV system based on known environmental input data. In this research, all available weather data are used to predict the PV power. Meteorological and power data are then analyzed using a statistical approach to identify the order of significance of the input variables. Then, a predictive model is suggested as a function of irradiance, ambient temperature, wind speed, and relative humidity. The model produces a root mean square error of 4.957% and a mean absolute percentage error of 5.468% during the measurement period and over the entire range of irradiation.

29 July 2019 in IEEE Journal of Photovoltaics
Verified
Journal Article
Open access
BBByeong Gwan Bhang
Byeong Gwan Bhang
WLWonbin Lee
Wonbin Lee
GKGyuGwang Kim
GyuGwang Kim
JCJin Ho Choi
Jin Ho Choi
SPSo Young Park
So Young Park
HYUNG KEUN AHNHYUNG KEUN AHN
HYUNG KEUN AHN
Unlike conventional photovoltaic (PV) modules that generate power by absorbing light through the front side only, a bifacial PV module can generate power by absorbing light through the rear as well as the front, which would lead to an enhancement of power generation. Particularly, bifacial PV modules would have the advantage of lower power loss in shaded environments than monofacial PV modules, thanks to the light absorbed through the rear side. To predict the power of a bifacial PV module in a shaded environment, modeling is suggested by considering the shaded areas, the operational status of the bypass diodes, and the temperature of the bifacial PV module. To verify the power prediction of a bifacial PV module with a shaded area, modeled and measured powers are compared, showing error rates of 7.28%. From the results of the power loss experiments for bifacial and monofacial PV modules in shaded environments, it is confirmed that the bifacial PV module shows a relatively low power loss rate when compared with the monofacial PV module, with a power loss rate being 87.26% of the rate for the monofacial PV module.

4 November 2020 in IEEE Journal of Photovoltaics
Verified
Journal Article
Open access
GKGyuGwang Kim
GyuGwang Kim
WLWonbin Lee
Wonbin Lee
BBByeong Gwan Bhang
Byeong Gwan Bhang
JCJin Ho Choi
Jin Ho Choi
HYUNG KEUN AHNHYUNG KEUN AHN
HYUNG KEUN AHN
Fault detection and repair of the components of photovoltaic (PV) systems are essential to avoid economic losses and facility accidents, thereby ensuring reliable and safe systems. This article presents a method to detect faults in a PV system based on power ratio (PR), voltage ratio (VR), and current ratio (IR). The lower control limit (LCL) and upper control limit (UCL) of each ratio were defined using the data of a test site system under normal operating conditions. If PR exceeded the set range, the algorithm considered a fault. Subsequently, PR and IR were examined via the algorithm to diagnose faults in the system as series, parallel, or total faults. The results showed that PR exceeded the designated range between LCL (0.93) and UCL (1.02) by dropping to 0.91–0.68, 0.88–0.62, and 0.66–0.33 for series, total, and parallel faults, respectively. Moreover, VR exceeded the LCL (0.99) and UCL (1.01) by 0.95–0.69 and 0.91–0.62 for series and total faults, respectively, but not under parallel faults condition. IR did not change in series and total faults but exceeded the range of LCL (0.93) and UCL (1.05) by dropping to 0.66–0.33. Thus, faults in PV systems can be detected and diagnosed by analyzing quantitative output values.

28 September 2018 in Applied Sciences
Verified
Journal Article
Open access
PDF file
HCHae Lim Cha
Hae Lim Cha
BBByeong Gwan Bhang
Byeong Gwan Bhang
SPSo Young Park
So Young Park
JCJin Ho Choi
Jin Ho Choi
HYUNG KEUN AHNHYUNG KEUN AHN
HYUNG KEUN AHN
A bifacial solar module has a structure that allows the rear electrode to be added to the existing silicon photovoltaic module structure. Thus, it can capture energy from both the front and rear sides of the module. In this paper, modeling is suggested to estimate the amount of energy generated from the rear of the bifacial photovoltaic module. After calculating the amount of irradiance from the rear side, the estimated power generation is compared with the real power output from the rear side of the module. The experiments were performed using four different environments with different albedos. The theoretical prediction of the model shows a maximum of 5% and average of 1.86% error in the measurement data. Based on the nature of the bifacial solar module, which receives additional irradiance from the rear side, this study compared the output amounts with respect to different rear environments. Recently, installation of floating Photovoltaic has been increasing. As the reflection of irradiation from the water surface occurs, the positive influence of the installation with the bifacial photovoltaic can be expected. We are confident that this research will contribute to zero energy construction by designing systems based on bifacial PV module with high performance ratio when applying solar power in a microgrid environment, which is the future energy.

16 August 2018 in IEEE Access
Verified
Journal Article
Open access
HLHyun Gu Lee
Hyun Gu Lee
GKGyuGwang Kim
GyuGwang Kim
BBByeong Gwan Bhang
Byeong Gwan Bhang
DKDavid Kwangsoon Kim
David Kwangsoon Kim
NPNeungsoo Park
Neungsoo Park
HYUNG KEUN AHNHYUNG KEUN AHN
HYUNG KEUN AHN
A distributed power generation system uses an intermittent power source that provides low power. Furthermore, it cannot be centrally controlled from the perspective of the system operator. The photovoltaic (PV) power generation system is installed with an energy storage system (ESS) to increase the power source quality compared to that possible with PV-only power generation. In this paper, an estimation algorithm is proposed for improving battery capacity to construct a suitable and economical system. In addition, an optimal algorithm is proposed that considers different factors. For example, the cost of constructing the battery and the amount of electric power sales reflecting the renewable energy certificate weighting factor of 5.0 are based on the cost of the battery construction, depth of battery discharge, charge/discharge cycle of the battery, cost of the energy conversion device, operation maintenance cost, and charge cycle of the battery. The optimized battery capacity is calculated by considering the correlation between PV power and meteorological parameters, construction cost, and the benefit of the amount of electricity sold, with an error rate of 5.75%.

1 September 2017 in Energies
Verified
Journal Article
Open access
PDF file
JKJae woo Ko
Jae woo Ko
HCHae Lim Cha
Hae Lim Cha
DKDavid Kwang-Soon Kim
David Kwang-Soon Kim
JLJong Rok Lim
Jong Rok Lim
GKGyu Gwang Kim
Gyu Gwang Kim
HYUNG KEUN AHNHYUNG KEUN AHN
HYUNG KEUN AHN
Underwater grounding methods could be applied in deep water for grounding a floating PV (photovoltaic) system. However, the depth at which the electrodes should be located is a controversial subject. In this study, grounding resistance was measured for the first time by analyzing the water temperature at different water depths in an area where a floating PV system is installed. The theoretical calculation of the grounding resistance has a maximum error range of 8% compared to the experimentally measured data. In order to meet the electrical safety standards of a floating PV system, a number of electrodes were connected in parallel. In addition, the distance between electrodes and number of electrodes were considered in the test to obtain a formula for the grounding resistance. In addition, the coefficient of corrosion was obtained from an electrode installed underwater a year ago, and it was added to the formula. Through this analysis, it is possible to predict the grounding resistance prior to installing the floating PV system. Furthermore, the electrical safety of the floating PV system could be achieved by considering the seasonal changes in water temperature.