Fuzzy logic inference system requires a long enough computational process, starting from fuzzification, matching rule base, drawing conclusions and defuzzification. By using C programming, fuzzy logic systems can be carried out by a low capability microcontrollers, for example PIC16F877A that has a flash memory capacity of 8KB and the maximum clock speed is 20 MHz. But if it will be applied to a microcontroller that has a smaller size of flash memory, there is a possibility that it cannot be realized, especially if it uses the gaussian membership function and each membership function inputs was devided in to more than three memberships. To overcome this problem we need a method to accelerate the fuzzy logic computation process. One of that method is using a linear interpolation from the table of input-output fuzzy system. In this paper, the linear interpolation was illustrated by using bilinear fuzzy interpolation. Based on the GNU Octave simulation, it was obtained data that the time being needed to complete the simulation for fuzzy bilinear Look Up Table has 7 times faster than the fuzzy system computation, whereas from the real implementation, it was obtained that fuzzy bilinear Look Up Table gives 2 times faster and can save program memory space around 25% compared to ordinary fuzzy system.
31 October 2024 in Techno (Jurnal Fakultas Teknik, Universitas Muhammadiyah Purwokerto)
Polusi udara menjadi salah satu ancaman bagi lingkungan, khususnya di kawasan perkotaan yang memiliki tingkat emisi tinggi gas berbahaya seperti karbon dioksida (CO2) dan karbon monoksida (CO). Penelitian ini mengembangkan sistem pemantauan kualitas udara berbasis sensor MQ-135 yang berfokus pada deteksi gas CO2 dan CO secara real-time. Sensor ini diintegrasikan dengan mikrokontroler dan kalibrasi algoritma untuk meningkatkan akurasi pengukuran. Penelitian ini menawarkan pendekatan yang lebih efisien dan ekonomis dibandingkan dengan perangkat monitoring komersial. Hasil pengujian menunjukkan bahwa sistem yang dikembangkan mampu mendeteksi konsentrasi gas dengan presisi yang dapat diterima untuk aplikasi lingkungan. Studi ini berkontribusi terhadap pengembangan teknologi monitoring udara yang lebih terjangkau untuk aplikasi perkotaan.
Three phase induction is the most common motor and is widely used in various industrial equipment because of all the advantages. To get the best performance, the quality of powersupply of induction motors needs to be maintained. One of the problems that arise in power quality is under voltage or over voltage. In this study the calculation and analysis of efficiency using the segregated loss method of 3 phase induction motors connected to stars and delta on the under voltage and over voltage conditions of the rating voltage, and at the rating voltage, the motor used is a 3 Phase 1 HP 4 pole induction motor with voltage rating of 380 volts. The method used is the segregated loss method, this method is a method to get the value of the efficiency of the induction motor by finding and separating the value of loss and loss, the method used refers to IEEE 112. Simulation using PSIM software as a hypothesis and comparison, variables taken are speed, current, inter-phase voltage and input power. Based on the results of calculations from all experiments show that the induction motor will produce better efficiency at loads approaching its capacity, and under voltage and over voltage conditions affect the efficiency value with a small difference in each change in voltage conditions. Efficiency values in all star motor voltage conditions range between 44% - 52% and in delta connection motor ranges between 39% - 42%. Simulations carried out using PSIM software produce higher efficiency than the test results with a range of values of 67% -78%, where the value is calculated from the simulation results and ignoring core losses.
11 October 2023 in Techno (Jurnal Fakultas Teknik, Universitas Muhammadiyah Purwokerto)
Pendemi Covid-19 pernah terjadi di akhir tahun 2019, walau pandemi sudah berlalu untuk usaha pencegahan kasus yang sama maka pengecekan suhu tubuh dan masker masih diberlakukan terutama ditempat publik misalnya di kantor perbankan dan sebagainya dan kenyataanya virus dapat bermutasi dan pernah ditemukan variannya. Penelitian ini merupakan penelitian lanjutan dari penulis tentang deteksi masker dengan menambahkan fitur pengecekan suhu tubuh untuk kontrol otomatis sistem buka tutup portal. Implementasi sistem dilakukan di mesin android model hasil pelatihan deteksi masker dilatih menggunakan machine learning dan deteksi suhu menggunakan sensor non kontak MLX90614. Berdasarkan pengujian sistem telah bekerja dengan baik, portal akan membuka secara otomatis jika pengunjung menggunakan masker dan suhu tubuh dibawah 37,5 oC.
9 October 2018 in IOP Conference Series: Materials Science and Engineering
Heart disease is the number one cause of death in the world. The heart functions to pump blood flowing through the veins or arteries to all parts of the body. In the blood contains many levels of molecules or constituents, such as oxygen in blood HbO2 (oxyhemoglobin). This study aims to design a system used to measure changes in voltage fluctuations to the transducer (photoplethysmography), oxygen saturation and changes in body heat. From the test result got error value at measurement of SpO2 equal to 0.89% and for measurement of BPM (heart rate) equal to 3.095%, difference or difference measurement of body temperature sensor got error value equal to 0.78%.
1 November 2019 in IOP Conference Series: Materials Science and Engineering
Visualization of the measurement results of magnitude is a matter that will facilitate us in understanding the measurement results. Visual media is more interesting to most people than text media. This study aims to design and create an application system based on GUI (Graphical User Interface) that can display the form of heart rate waves, oxygen saturation in the blood, and body temperature. The measurement information is computed to produce a decision stored in the database. From the test results, the system can display the waveform of heart rate, oxygen saturation in blood and body temperature and diagnosis appears.