13 December 2022 in Solar Energy
13 September 2023 in Renewable Energy
1 January 2022 in Journal of Renewable and Sustainable Energy
This paper aims to investigate the influence of active cooling and natural cooling on the electrical performance of photovoltaic (PV) modules in a cold highland area in winter, and the thermal performance of two photovoltaic thermal (PV/T) systems for space heating. A comparative system with exactly the same size of a PV system, liquid-cooled PV/T system, and heat pipe PV/T system was designed and constructed in Ganzi city, China. The energy performance of these systems was tested under real weather conditions for several days. The experimental results show that the PV module can achieve the cooling effect by natural cooling, with a daily average temperature between 30 °C and 40 °C, and an electrical efficiency 3.71% higher than that of active cooling. However, the temperature of naturally cooled PV modules fluctuates drastically with time, and the temperature changes above 10 °C in a short time. The solar energy conversion efficiency of PV/T systems is more than 2.67 times that of a PV system. The heating power of the liquid-cooled PV/T system and heat pipe PV/T system can reach 847.4 and 948.5 W, and the primary-energy saving efficiency can reach 68.8% and 76.7%. A comparison of the intercept efficiency shows that the heat pipe PV/T system has the best energy performance.
1 November 2021 in Journal of Renewable and Sustainable Energy
Over the recent years, the energy use of artificial lighting has been gradually increasing in office buildings. Tubular daylight guidance system (TDGS) is an innovative daylighting technology, which is used to transport daylight into the core of a building. In this study, the effects of the tube radius of TDGSs, window-to-wall ratio (WWR), and window orientation on the indoor illuminance, artificial lighting electricity consumption, and heating/cooling loads of an office room are investigated for the five climate zones in China by both numerical simulations and experiments. The model is developed using Radiance and Ecotect, and its feasibility is validated by comparing the simulated indoor illuminance distributions with the field measurements. The results demonstrate that the increase in the tube radius and the decrease in the WWR and the utilization of a north-facing window can improve the daylighting performance and energy savings of the TDGSs. In general, the TDGSs can reduce the artificial lighting electricity consumption and heating load while increasing the cooling load of the office room. Due to the implementation of TDGSs, the maximum potential energy savings (on the lighting energy use and the heating/cooling energy use) are 27.6% in Kunming (moderate climate), 13.5% in Chengdu (hot summer and cold winter), 10.6% in Guangzhou (hot summer and warm winter), 10.3% in Beijing (cold), and 5.0% in Harbin (severe cold).
12 September 2022 in Journal of Thermal Science