Samuel Patz

Samuel Patz

Auto-generated profile, based on publicly available information

Samuel Patz

Department of Radiology, Brigham and Women's Hospital, Boston, MA, USA

Research Focus & Metrics

Academic Career Length

46Years (1981-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 1995 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
HGHákon Gudbjartsson
Hákon Gudbjartsson
SPSamuel Patz
Samuel Patz

19 July 2012 in New England Journal of Medicine
Verified
Journal Article
Closed access
PDF file
JBJames P. Butler
James P. Butler
SLStephen H. Loring
Stephen H. Loring
SPSamuel Patz
Samuel Patz
ATAkira Tsuda
Akira Tsuda
DYDmitriy Yablonskiy
Dmitriy Yablonskiy
SMSteven Mentzer
Steven Mentzer
A 33-year-old woman underwent a right-sided pneumonectomy in 1995 for treatment of a lung adenocarcinoma. As expected, there was an abrupt decrease in her vital capacity, but unexpectedly, it increased during the subsequent 15 years. Serial computed tomographic (CT) scans showed progressive enlargement of the remaining left lung and an increase in tissue density. Magnetic resonance imaging (MRI) with the use of hyperpolarized helium-3 gas showed overall acinar-airway dimensions that were consistent with an increase in the alveolar number rather than the enlargement of existing alveoli, but the alveoli in the growing lung were shallower than in normal lungs. This study provides evidence that new lung growth can occur in an adult human.

5 January 2010 in Neurology
Verified
Journal Article
Closed access
PDF file
JBJ. S. Buell
J. S. Buell
BDB. Dawson-Hughes
B. Dawson-Hughes
TST. M. Scott
T. M. Scott
DWD. E. Weiner
D. E. Weiner
GDG. E. Dallal
G. E. Dallal
KTKatherine Tucker
Katherine Tucker
Background: Vitamin D deficiency has potential adverse effects on neurocognitive health and subcortical function. However, no studies have examined the association between vitamin D status, dementia, and cranial MRI indicators of cerebrovascular disease (CVD). Methods: Cross-sectional investigation of 25-hydroxyvitamin D [25(OH)D], dementia, and MRI measures of CVD in elders receiving home care (aged 65–99 years) from 2003 to 2007. Results: Among 318 participants, the mean age was 73.5 ± 8.1 years, 231 (72.6%) were women, and 109 (34.3%) were black. 25(OH)D concentrations were deficient (<10 ng/mL) in 14.5% and insufficient (10–20 ng/mL) in 44.3% of participants. There were 76 participants (23.9%) with dementia, 41 of which were classified as probable AD. Mean 25(OH)D concentrations were lower in subjects with dementia (16.8 vs 20.0 ng/mL, p < 0.01). There was a higher prevalence of dementia among participants with 25(OH)D insufficiency (≤20 ng/mL) (30.5% vs 14.5%, p < 0.01). 25(OH)D deficiency was associated with increased white matter hyperintensity volume (4.9 vs 2.9 mL, p < 0.01), grade (3.0 vs 2.2, p = 0.04), and prevalence of large vessel infarcts (10.1% vs 6.9%, p < 0.01). After adjustment for age, race, sex, body mass index, and education, 25(OH)D insufficiency (≤20 ng/mL) was associated with more than twice the odds of all-cause dementia (odds ratio [OR] = 2.3, 95% confidence interval [CI] 1.2–4.2), Alzheimer disease (OR = 2.5, 95% CI 1.1–6.1), and stroke (with and without dementia symptoms) (OR = 2.0, 95% CI 1.0–4.0). Conclusions: Vitamin D insufficiency and deficiency was associated with all-cause dementia, Alzheimer disease, stroke (with and without dementia symptoms), and MRI indicators of cerebrovascular disease. These findings suggest a potential vasculoprotective role of vitamin D.

1 October 1996 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
HGHákon Gudbjartsson
Hákon Gudbjartsson
SMStephan E. Maier
Stephan E. Maier
RMRobert V. Mulkern
Robert V. Mulkern
IMIstván Á. Mórocz
István Á. Mórocz
SPSamuel Patz
Samuel Patz
FJFerenc A. Jolesz
Ferenc A. Jolesz

14 August 2013 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
PDF file
PNPanayiotis Nikolaou
Panayiotis Nikolaou
ACAaron M. Coffey
Aaron M. Coffey
LWLaura L. Walkup
Laura L. Walkup
BGBrogan M. Gust
Brogan M. Gust
NWNicholas Whiting
Nicholas Whiting
BGBoyd M. Goodson
Boyd M. Goodson
The exquisite NMR spectral sensitivity and negligible reactivity of hyperpolarized xenon-129 (HP129Xe) make it attractive for a number of magnetic resonance applications; moreover, HP129Xe embodies an alternative to rare and nonrenewable 3He. However, the ability to reliably and inexpensively produce large quantities of HP129Xe with sufficiently high 129Xe nuclear spin polarization (PXe) remains a significant challenge—particularly at high Xe densities. We present results from our “open-source” large-scale (∼1 L/h) 129Xe polarizer for clinical, preclinical, and materials NMR and MRI research. Automated and composed mostly of off-the-shelf components, this “hyperpolarizer” is designed to be readily implementable in other laboratories. The device runs with high resonant photon flux (up to 200 W at the Rb D1 line) in the xenon-rich regime (up to 1,800 torr Xe in 500 cc) in either single-batch or stopped-flow mode, negating in part the usual requirement of Xe cryocollection. Excellent agreement is observed among four independent methods used to measure spin polarization. In-cell PXe values of ∼90%, ∼57%, ∼50%, and ∼30% have been measured for Xe loadings of ∼300, ∼500, ∼760, and ∼1,570 torr, respectively. PXe values of ∼41% and ∼28% (with ∼760 and ∼1,545 torr Xe loadings) have been measured after transfer to Tedlar bags and transport to a clinical 3 T scanner for MR imaging, including demonstration of lung MRI with a healthy human subject. Long “in-bag” 129Xe polarization decay times have been measured (T1 ∼38 min and ∼5.9 h at ∼1.5 mT and 3 T, respectively)—more than sufficient for a variety of applications.

18 October 1999 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
RMR. W. Mair
R. W. Mair
GWG. P. Wong
G. P. Wong
DHD. Hoffmann
D. Hoffmann
MHM. D. Hürlimann
M. D. Hürlimann
SPS. Patz
S. Patz
RWR. L. Walsworth
R. L. Walsworth
We show that gas diffusion nuclear magnetic resonance (GD-NMR) provides a powerful technique for probing the structure of porous media. In random packs of glass beads, using both laser-polarized and thermally polarized xenon gas, we find that GD-NMR can accurately measure the pore space surface-area–to–volume ratio, S/Vp, and the tortuosity, α (the latter quantity being directly related to the system's transport properties). We also show that GD-NMR provides a good measure of the tortuosity of sandstone and complex carbonate rocks.