Liu-Jun Zhao

Liu-Jun Zhao

Auto-generated profile, based on publicly available information

Liu-Jun Zhao

Department of Spinal Surgery, Ningbo No. 6 Hospital, Ningbo, 315040 Zhejiang Province, China

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 August 2022 in Computational and Mathematical Methods in Medicine
Verified
Journal Article
Open access
PDF file
JZJihui Zhang
Jihui Zhang
LZLiujun Zhao
Liujun Zhao
JXJingfei Xu
Jingfei Xu
YGYongjie Gu
Yongjie Gu
LYLiang Yu
Liang Yu
Objective. To study the optimum entry point and trajectory for anterior transpedicular root screw (ATPRS) placement into the lower cervical spine (LCS), so as to provide a basis for clinical application. Methods. A retrospective analysis of cervical CT images of patients who underwent cervical CT examination in the Spinal Surgery of Ningbo No. 6 Hospital from January 2020 to August 2021 was conducted. The data were obtained and modeled. On the coronal plane, the vertebral body (VB) between the anterior midline of cervical vertebral segments C3-7 and the left P line (by drawing the line parallel to the anterior midline of the VB at the intersection of the anterior edge of the Luschkas joint and the upper endplate) was equally divided into 9 zones (a-i). The ideal entry point and path of cervical ATPRS were designed and recorded. Additionally, 7 cadaveric specimens were selected, and the screw placement parameters were regenerated according to the above methods for screw placement. Results. Zone i of each segment, with the longest screw length, was the best area for screw placement. In all patients, the horizontal angles of vertebrae C3-7 in zones a, d, and g, zones b, e, and h, and zones c, f, and i showed a gradually decreasing trend. The sagittal angle range of C3-7 in all patients showed a gradually increasing trend in zones a-c, d-f, and g-i. The distance from the anterior midline of C3-7 to the P line increased in all patients, and the distance was longer in males than in females, with statistical significance. Pedicle screws were successfully inserted in all the 7 cadaveric specimens. Conclusions. ATPRS placement can be used for LCS internal fixation, and the precise screw placement parameters can be simulated by the software, which provides theoretical basis for its future clinical application.


1 February 2011
Verified
Journal Article
Closed access
GLGuan-Yi Liu
Guan-Yi Liu
RXRong-Ming Xu
Rong-Ming Xu
WMWei-Hu Ma
Wei-Hu Ma
SSShao-Hua Sun
Shao-Hua Sun
HLHua-Jie Lin
Hua-Jie Lin
LZLei-Jie Zhou
Lei-Jie Zhou
To explore the feasibility and the technical parameters in posterior C2 spinous process laminar screw fixation, and discuss the clinic significance of C2 spinous process laminar screws. Twenty cervical cadaveric spines of C2 were dissected, with care taken to expose the lamina and spinous process. After the entrance point of spinous process screw were determined, posterior C2 spinous process laminar screw implantation was performed under visual control. On the morphologic CT scan, the angle and length of the spinous process laminar screw trajectory and the distance between the tip of the screw and the spinal cord and the vertebral artery were measured. The C2 spinous process laminar screws were successfully placed, without impingement of the spinal cord and the vertebral artery. There were little differences between superior and inferior screws in the angle, trajectory length and the distance between the tip of the screw and the spinal cord and the vertebral artery, but without significance (P > 0.05). The placed angles of the screws were 76.8° ± 10.6° in the axial plane. The distance between the tip of the screw and the spinal cord and the vertebral artery was (5.3 ± 1.6) mm and (17.4 ± 3.7) mm respectively. The trajectory length was (23.1 ± 3.2) mm. Posterior C2 spinous process laminar screw fixation is feasible. C2 spinous process laminar screw fixation affords an alternative to standard screw placement for plate fixation and cervical stabilization.