We report new observations of the infrared (IR) spectrum of low-current Th-Ar hollow cathode lamps with the 2 m Fourier transform spectrometer (FTS) at the National Institute of Standards and Technology. These observations establish more than 2400 lines that are suitable for use as wavelength standards in the range 900-4500 nm. The line list is used as input for a physical instrument model that provides the wavelength calibration for the Cryogenic High-Resolution IR Echelle Spectrometer (CRIRES), the European Southern Observatory's new high-resolution -->(R ~ 100,000) IR spectrograph at the Very Large Telescope. We have also observed the variation of the spectrum of Th-Ar lamps as a function of operating current. The results allow us to optimize the spectral output in terms of relative intensity and line density for operation on the telescope. Our results should be generally useful for wavelength calibration in near-IR astronomy, providing a high density of sharp, well-characterized emission lines with the ease and efficiency of operation of a commercial discharge lamp.
Observations of mercury lines in the HgMn stars χ Lupi and HR 7775 made with the Hubble Space Telescope Goddard High Resolution Spectrograph are presented and analyzed. In χ Lupi we find that all observed lines are consistent with the same isotopic mixture (essentially pure 204Hg). Strong ionization anomalies are present, with UV Hg I lines being too weak and Hg III lines too strong for the abundance derived from lines of the majority ionization state, Hg II. Observations of mercury in HR 7775 show less extreme isotope and ionization anomalies. We find that the ionization anomaly in the Hg I resonance lines can be plausibly explained as a non-LTE effect, but the same non-LTE calculations show that the Hg III ionization anomaly in χ Lupi cannot be explained in this way. Radiative force calculations show that the observed mercury abundance cannot be supported in the atmosphere by the radiative forces alone. We suggest that weak mixing brings mercury into the line-forming region from below the photosphere, while a wind of order 10-14M☉ yr-1 supports a cloud of Hg III at very small optical depths.
1 April 1990 in The Astrophysical Journal Supplement Series
We report laboratory measurements to characterize the spectral output of platinum/chromium hollow cathode lamps containing neon carrier gas. The spectra were recorded photographically with the National Institute of Standards and Technology 10.7 m normal-incidence spectrograph. The lamps investigated are equivalent to the lamps used for wavelength calibration of the Space Telescope Imaging Spectrograph (STIS) on board the Hubble Space Telescope. Wavelengths and intensities are given for more than 1200 lines in the wavelength range 1132-1827 Å. The uncertainty of the measured wavelengths is estimated to be ±0.0020 Å. During an aging test mimicking the operations on board STIS one Pt/Cr-Ne lamp has passed 1000 hr of operation and is still in excellent working condition. This suggests that such a lamp can be operated for significantly more than 10 years and that it will not be a limiting factor for the useful lifetime of STIS.
The wavelengths of six spectral lines emitted by a molecular fluorine (F2) laser at 157 nm were measured to high accuracy with the 10.7-m normal-incidence vacuum spectrograph at the National Institute of Standards and Technology. Lines from a Pt–Ne hollow-cathode lamp served as the wavelength standards. Spectra of the laser and the Pt–Ne lamp were photographed simultaneously through an uncoated CaF2 beam splitter. The optical paths were arranged so as to avoid shifts in line positions arising from possible differences in illumination of the grating by the two sources. The strongest lasing line was found to have a wavelength of 157.63094(10) nm. Changes in wavelength for variations in gas mixture, total gas pressure, and voltage were also measured.
1 November 2007 in Journal of Research of the National Institute of Standards and Technology
Recent observations at the National Institute of Standards and Technology indicate that the Ar I wavenumbers reported by Whaling et al. [J. Res. Natl. Inst. Stand. Technol. 107, 149 (2002)] are systematically too large. To investigate the source of this problem, selected lines of Ar I and Ar II were remeasured in the same spectra used by Whaling et al. The measurements show that the Ar I wavenumbers of Whaling et al. are systematically shifted with respect to the Ar II wavenumbers previously reported by Whaling et al. [J. Quant. Spectrosc. Radiat. Transfer 53, 1 (1995)] based on the same spectra. The Ar I wavenumbers can be corrected by a constant multiplicative correction of 0.999 999 933.