Allard J. Katan

Allard J. Katan

Auto-generated profile, based on publicly available information

Allard J. Katan

Department of Bionanoscience, Kavli Institute of Nanoscience Delft, Delft University of Technology, Delft, the Netherlands

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 November 2010 in Physical Review Letters
Verified
Journal Article
Closed access
JSJan Seidel
Jan Seidel
PMP. Maksymovych
P. Maksymovych
YBY. Batra
Y. Batra
AKA. Katan
A. Katan
SYS.-Y. Yang
S.-Y. Yang
RRR. Ramesh
R. Ramesh
The transport physics of domain wall conductivity in La-doped bismuth ferrite (BiFeO3) has been probed using variable temperature conducting atomic force microscopy and piezoresponse force microscopy in samples with arrays of domain walls in the as-grown state. Nanoscale current measurements are investigated as a function of bias and temperature and are shown to be consistent with distinct electronic properties at the domain walls leading to changes in the observed local conductivity. Our observation is well described within a band picture of the observed electronic conduction. Finally, we demonstrate an additional degree of control of the wall conductivity through chemical doping with oxygen vacancies, thus influencing the local conductive state.

26 April 2005 in Review of Scientific Instruments
Verified
Journal Article
Closed access
MRM. J. Rost
M. J. Rost
LCL. Crama
L. Crama
PSP. Schakel
P. Schakel
ETE. van Tol
E. van Tol
GVG. B. E. M. van Velzen-Williams
G. B. E. M. van Velzen-Williams
JFJ. W. M. Frenken
J. W. M. Frenken
In this article we introduce a, video-rate, control system that can be used with any type of scanning probe microscope, and that allows frame rates up to 200images∕s. These electronics are capable of measuring in a fast, completely analog mode as well as in the more conventional digital mode. The latter allows measurements at low speeds and options, such as, e.g., atom manipulation, current–voltage spectroscopy, or force–distance curves. For scanning tunneling microscope (STM) application we implemented a hybrid mode between the well-known constant-height and constant-current modes. This hybrid mode not only increases the maximum speed at which the surface can be imaged, but also improves the resolution at lower speeds. Acceptable image quality at high speeds could only be obtained by pushing the performance of each individual part of the electronics to its limit: we developed a preamplifier with a bandwidth of 600kHz, a feedback electronics with a bandwidth of 1MHz, a home-built bus structure for the fast data transfer, fast analog to digital converters, and low-noise drivers. Future improvements and extensions to the control electronics can be realized easily and quickly, because of its open architecture with its modular plug-in units. In the second part of this article we show our high-speed results. The ultrahigh vacuum application of these control electronics on our (UHV)-STM enabled imaging speeds up to 0.3mm∕s, while still obtaining atomic step resolution. At high frame rates, the images suffered from noticeable distortions, which we have been able to analyze by virtue of the unique access to the error (dZ) signal. The distortions have all been associated with mechanical resonances in the scan head of the UHV-STM. In order to reduce such resonance effects, we have designed and built a scan head with high resonance frequencies (⩾64kHz), especially for the purpose of testing the fast electronics. Using this scanner we have reached video-rate imaging speeds up to 200frames∕s (5ms∕image), while still obtaining atomically resolved structures.

12 February 2021 in Science Advances
Verified
Journal Article
Open access
PDF file
JRJe-Kyung Ryu
Je-Kyung Ryu
CBCéline Bouchoux
Céline Bouchoux
HLHon Wing Liu
Hon Wing Liu
EKEugene Kim
Eugene Kim
MMMasashi Minamino
Masashi Minamino
CDCees Dekker
Cees Dekker
Yeast cohesin complexes cluster onto long DNA into liquid droplets, which they accomplish by ATP-independent DNA bridging.

21 October 2011 in Nano Letters
Verified
Journal Article
Closed access
IVIwijn De Vlaminck
Iwijn De Vlaminck
THThomas Henighan
Thomas Henighan
MLMarijn T.J. van Loenhout
Marijn T.J. van Loenhout
IPIndriati Pfeiffer
Indriati Pfeiffer
JHJulius Huijts
Julius Huijts
CDCees Dekker
Cees Dekker

1 December 2011 in Ultramicroscopy
Verified
Journal Article
Closed access
JRJoost Te Riet
Joost Te Riet
AKAllard J. Katan
Allard J. Katan
CRChristian Rankl
Christian Rankl
SSStefan W. Stahl
Stefan W. Stahl
ABArend M. van Buul
Arend M. van Buul
SSSylvia Speller
Sylvia Speller

1 April 2009 in Nanotechnology
Verified
Journal Article
Closed access
AKAllard J Katan
Allard J Katan
MEMaarten H van Es
Maarten H van Es
TOTjerk H Oosterkamp
Tjerk H Oosterkamp
A new method for extracting quantitative data from amplitude modulation dynamic force-distance measurements is developed. The method is based on the harmonic oscillator model of vibrating atomic force microscope cantilevers, and is capable of extracting both the conservative and dissipative parts of the tip-sample interaction from a measurement of oscillation amplitude and phase as a function of distance. Numerical simulations are used to demonstrate the validity of the method. Further proof of the accuracy of this method is provided by a measurement of electrostatic forces between an AFM tip and a graphite sample.