12 April 2023 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
QOQiang Ou
Qiang Ou
LLLongfu Luo
Longfu Luo
YLYong Li
Yong Li
RHRong Han
Rong Han
YPYanjian Peng
Yanjian Peng
The inner winding of the power transformer is subjected to uniform compressive stress in the radial direction during the short circuit, which makes circular radial stability a crucial component of reliability. The radial stability evaluation system currently needs more state characteristic judgment quantity considering the manufacturing deviations(MD) and assembly gaps. Thus, there is a significant deviation in the transformer design, which seriously endangers the operation safety of the power system. This paper proposes an improved radial buckling analysis method (IRBAM) to investigate the circular radial stability of inner winding. The IRBAM is implemented by defining two characteristic parameters: equivalent flexibility and MD. Besides, the relative change ratio of impedance (RCRI) is proposed as the buckling judgment for ending each short-circuit test. The destructive short-circuit tested transformer is designed with the rated power of 50 MVA and the high-voltage (HV) rated voltage of 110 kV. Then, 73 cumulative short-circuit tests are performed until impedance exceeds the permissible value based on the judgment. Finally, it is verified that IRBAM can effectively match the winding failure modes by comparing the buckling phenomena and calculation results. Further, the IRBAM can provide a reference for similar designs and verification with more minor deviations.

2 January 2023 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
QOQiang Ou
Qiang Ou
LLLongfu Luo
Longfu Luo
YLYong Li
Yong Li
YLYantao Lin
Yantao Lin
YTYe Tian
Ye Tian
The extra‐high voltage (EHV) transformer winding disks are subjected to dynamic electromagnetic forces caused by short‐circuit currents. These periodically decaying impact forces may endanger the safety of the transformer. The winding constraint conditions around the circumference are different due to the influence of axial pressure structures and magnetic boundaries. Moreover, this difference becomes more evident as the voltage and capacity increase. To investigate the spatial differences and time effects of EHV transformer short‐circuit faults, this paper proposes a reliability evaluation method based on dynamic relative displacement (DRDEM) for the first time. Firstly, the suitable and efficient analysis method is summarized by comparing the deviation among different calculated impedances and the measured value. Then, the space‐time effect of windings is obtained by the static magnetic field and dynamic structural field based on equivalent compression supports. Furthermore, a 50 MVA/110 kV transformer is designed for the destructive short‐circuit test to simulate the short‐circuit ability feature of the EHV transformer. The disassembly phenomena after all the tests indicate that the DRDEM is more adaptable in characterizing the winding ability to withstand short circuit when investigating the spatial differences and time effects.

23 January 2023 in IEEE Access
Verified
Journal Article
Open access
QOQiang Ou
Qiang Ou
LLLongfu Luo
Longfu Luo
YLYong Li
Yong Li
YLYing Li
Ying Li
JXJinwen Xiang
Jinwen Xiang
Power transformers are inevitably subjected to external short circuit impact during their service period. The electromagnetic force generated by the fault current may cause winding destabilization and collapse. The radial buckling of the inner winding accounts for a considerable proportion. Based on the effective contact of the sticks, the traditional analytical methods ignore the manufacturing deviation and operation impact (MDOI) characterized by assembly gaps and insulation shrinkage. To address the limitation of the contact-constrained approach, this paper proposes the equivalent support stiffness (ESS) analytical method. The ESS method can investigate the issues of support weakening and failure, which are affected mainly by assembly gaps and insulation shrinkage. Further, two transformers are implemented in the short-circuit tests to demonstrate the feasibility of the ESS method. Among them, the assembly gaps are investigated by the first and second windings of the newly manufactured transformer, and the influence of insulation shrinkage is researched through a 30-year-old transformer. Furthermore, the application of the ESS method is expressed based on the tests and the simulations. The research presents quantitative references for transformer design and operational reliability assessment. The ESS method can be an improvement and supplement to traditional methods.

6 March 2025 in IEEE Access
Verified
Journal Article
Open access
QOQiang Ou
Qiang Ou
ZZZongxi Zhang
Zongxi Zhang
RZRuichi Zeng
Ruichi Zeng
Power transformers play a pivotal role in power grids, yet they are invariably exposed to short-circuit impacts. Precise assessment of the winding mechanical strength is crucial for ensuring power grid security. Nevertheless, traditional short-circuit tests face significant challenges in identifying critical stability states due to the high cost and destructive nature, which impedes the accurate assessment of winding strength. To address this issue, this paper proposes an improved buckling hoop stress investigation (IBHSI) test method that focuses on the inner windings. The novelty of this approach lies in its utilization of the non-equivalent force characteristics exhibited by winding disks along the height. Departing from conventional practices, it enables the accurate determination of the winding buckling hoop stress with a limited number of transformer samples and test times. Initially, a representative transformer is meticulously selected. By preliminarily estimating the winding’s critical withstand current, a series of short-circuit tests as described in this paper are implemented. Afterward, the transformer is disassembled to identify the location where gradual deformation occurs. Through a secondary simulation focused this specific position, the buckling hoop stress can be precisely calculated. The IBHSI method not only significantly enhances the verification ability of short-circuit withstand capacity but also provides a novel and more precise means of assessing winding stability, effectively compensating for the inadequacies of traditional testing methods.

24 November 2025 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
AKArsalan Habib Khawaja
Arsalan Habib Khawaja
Qi HuangQi Huang
Qi Huang
DCDongsheng Cai
Dongsheng Cai
TCTianxiang Chen
Tianxiang Chen
WLWei Liu
Wei Liu
QOQiang Ou
Qiang Ou
Power distribution network is a critical link of Power grid throughout the world, where overhead power lines transport electricity from substation to the consumers end. Short circuit faults are common and contribute to more than 50% for the total faults in distribution lines, mainly due to insulation failures, vegetation growth, birding and line intrusion. Such non-clearing faults require manual faulted span retrieval which results in longer outage times and enormous human effort. This work presents and demonstrate a complete system level approach to automates manual fault localization by non-contact magnetic sensing, its processing and rapid reporting of faulted span length. This results in reduced outage time for customers, less patrolling, and improved safety of line personnel. To test and validate, this article further designs a novel Remote Terminal Unit (RTU) to track weak magnetic signatures radiated from overhead lines in a non-contact arrangement to detect and identify distribution line status. The state from deployed RTUs is further transmitted to cloud-based algorithm to identify faulted span length. The RTU is developed to cater for real world modalities such as ease of installation at a distance from live conductors, and ability to withstand geomagnetic, ferromagnetic as well as intrinsic sensor noise. The presented system is implementable to radial as well as meshed based modern power systems with an inbuilt mechanism to prevent false alarm in events of back feeding and inrush current. High voltage lab and extensive on-field testing verifies the overall system efficacy to successfully localize the faulted span length.

1 January 2026 in IET Science, Measurement & Technology
Verified
Journal Article
Open access
PDF file
QOQiang Ou
Qiang Ou
HNHaoru Ning
Haoru Ning
WLWeiwei Liu
Weiwei Liu
GCGuangsheng Chen
Guangsheng Chen
The short‑circuit withstand capability of transformer windings is critical to the safe and stable operation of modern power systems. Conventional static calculation approaches commonly suffer from insufficient assessment accuracy, whereas traditional full destructive short‐circuit tests involve substantial economic costs and irreversible equipment damage in practical engineering. To address these technical limitations, this paper proposes a Dynamic Sensing and Real‐time Evaluation (DSRE) method for quantitative assessment of winding short‐circuit strength. Through dynamic monitoring of the evolution of short‐circuit impedance and vibration signal under successive short‐circuit tests, a real‐time quantitative evaluation framework that accounts for cumulative plastic damage is constructed. The typical impedance deterioration observed under low‑magnitude short‑circuit current reflects the technical advantages of the dynamic DSRE strategy over conventional static analysis. Combined with finite‑element calculations of internal electromagnetic force distributions, the proposed method enables reliable identification and early warning of the critical instability state of transformer windings. Systematic tests on a 110 kV three‐phase three‐winding transformer demonstrate that the integration of the sensing module and software evaluation platform improves the accuracy of short‐circuit strength verification and the reliability of winding condition assessment. This work provides a potential approach for the real‐time assessment of 110 kV transformer winding short‐circuit withstand capacity.