Hernan Gerardo Marcos-Abdala

Hernan Gerardo Marcos-Abdala

Auto-generated profile, based on publicly available information

Hernan Gerardo Marcos-Abdala

Houston Methodist Research Institute, Houston, TX, USA

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 March 2023 in The International Journal of Artificial Organs
Verified
Journal Article
Closed access
MKMahwash Kassi
Mahwash Kassi
TATanushree Agrawal
Tanushree Agrawal
JXJiaqiong Xu
Jiaqiong Xu
HMHernan Gerardo Marcos-Abdala
Hernan Gerardo Marcos-Abdala
RARaquel Araujo-Gutierrez
Raquel Araujo-Gutierrez
JEJerry Estep
Jerry Estep
We sought to evaluate whether differences in left ventricular assist device (LVAD) canula alignment are associated with stroke. There is a paucity of clinical data on contribution of LVAD canulae alignment to strokes. We conducted a retrospective analysis of patients who underwent LVAD implantation at Houston Methodist hospital from 2011 to 2016 and included those who had undergone cardiac computed tomography (CT) with contrast. LVAD graft alignment using X-ray, echocardiography, and cardiac CT was evaluated. The primary outcome was stroke within 1 year of LVAD implantation. Of the 101 patients that underwent LVAD Implantation and cardiac CT scan during the study period, 78 met inclusion criteria. The primary outcome occurred in 12 (15.4%) patients with a median time to stroke of 77 days (interquartile range: 42–132 days). Of these, 10 patients had an ischemic and two had hemorrhagic strokes. The predominant device type was Heart Mate II (94.8%). Patients with LVAD outflow cannula to aortic angle lesser than 37.5° and those with outflow graft diameter of anastomosis less than 1.5 cm (assessed by cardiac CT) had significantly higher stroke risk ( p < 0.001 and p = 0.01 respectively). In HMII patients, a lower LVAD speed at the time of CT scan was associated with stroke. Further studies are needed to identify optimal outflow graft configuration to mitigate stroke risk.

Verified
Journal Article
Open access
PDF file
RTRishi Thaker
Rishi Thaker
RARaquel Araujo-Gutierrez
Raquel Araujo-Gutierrez
HMHernan G. Marcos-Abdala
Hernan G. Marcos-Abdala
TATanushree Agrawal
Tanushree Agrawal
NFNadia Fida
Nadia Fida
MKMahwash Kassi
Mahwash Kassi
Left ventricular assist devices (LVAD) cause altered flow dynamics that may result in complications such as stroke, pump thrombosis, bleeding, or aortic regurgitation. Understanding altered flow dynamics is important in order to develop more efficient and durable pump configurations. In patients with LVAD, hemodynamic assessment is limited to imaging techniques such as echocardiography which precludes detailed assessment of fluid dynamics. In this review article, we present some innovative modeling techniques that are often used in device development or for research purposes, but have not been utilized clinically. Computational fluid dynamic (CFD) modeling is based on computer simulations and particle image velocimetry (PIV) employs ex vivo models that helps study fluid characteristics such as pressure, shear stress, and velocity. Both techniques may help elaborate our understanding of complications that occur with LVAD and could be potentially used in the future to troubleshoot LVAD-related alarms. These techniques coupled with 3D printing may also allow for patient-specific device implants, lowering the risk of complications increasing device durability.

14 October 2020 in ASAIO Journal
Verified
Journal Article
Closed access
AAAreeba Ali
Areeba Ali
CUCesar Uribe
Cesar Uribe
RARaquel Araujo-Gutierrez
Raquel Araujo-Gutierrez
ACAna S. Cruz-Solbes
Ana S. Cruz-Solbes
HMHernan G. Marcos-Abdala
Hernan G. Marcos-Abdala
ABArvind Bhimaraj
Arvind Bhimaraj
Endothelial dysfunction has been demonstrated in patients with Continuous Flow-Left Ventricular Assist Devices (CF-LVADs) but association with adverse events has not been shown. We used a noninvasive, operator-independent device called VENDYS® to assess vasodilatory function based on digital thermal measurements postrelease of a brachial artery occlusion in ambulatory patients with CF-LVAD (n = 56). Aortic valve opening and pulse perception were also documented before the test. Median duration of CF-LVAD support was 438 days. The VENDYS® test generates a vascular reactivity index (VRI). Outcomes for the CF-LVAD patients were compared between VRI < 1 and VRI ≥ 1. The bleeding events were driven primarily by a difference in neurologic bleeds. Multivariate analysis showed that VRI < 1 correlated with future bleeding events (HR: 5.56; P = 0.01). The C-statistic with the VRI dichotomized as above was 0.82. There was a trend toward a worse survival in patients with poor endothelial function. Endothelial vasodilatory dysfunction measured by a simple test utilizing digital thermal monitoring can predict adverse bleeding events in patients with CF-LVADs.

5 June 2020 in The International Journal of Artificial Organs
Verified
Journal Article
Closed access
PDF file
HMHernan G Marcos-Abdala
Hernan G Marcos-Abdala
ACAna S Cruz-Solbes
Ana S Cruz-Solbes
IHImad Hussain
Imad Hussain
BTBarry Trachtenberg
Barry Trachtenberg
GAGuha Ashrith
Guha Ashrith
ABArvind Bhimaraj
Arvind Bhimaraj
While Doppler and cuff blood pressure techniques are prevalent methods of assessing blood pressure in patients with continuous flow left ventricular assist devices, the impact of pulsatility on measurement is not well established. Retrospective chart analysis of clinical variables including pulse perception, blood pressure (Doppler and standard cuff), and aortic valve opening on echo at clinic visit were abstracted. Stable outpatients on continuous flow left ventricular assist devices support with concomitant portable echo assessment were included. Mean average difference was calculated and Pearson’s correlation performed for all those patients who had both Doppler and cuff pressure obtained. In all, 74 Heartmate-II patients with a median time from implant of 380 days were analyzed. A pulse was perceived in 82% of patients with persistent aortic valve opening on portable echo and also in 30% of those who had a persistently closed aortic valve. The mean average difference between the Doppler and systolic cuff pressure was ~13 mmHg (r = 0.5, p = 0.004) when a pulse was present and ~11 mmHg when aortic valve was open (r = 0.68, p < 0.0001). Pulse presence seems to reflect aortic valve opening a majority of the time but not always. In the presence of a prominent pulse or persistent aortic valve opening, the Doppler pressure seems to be more reflective of a systolic pressure than mean perfusion pressure. Hence, assessment of pulsatility needs to be incorporated into blood pressure measurement methods for patients with continuous flow left ventricular assist devices.