Courtney Wilson

Courtney Wilson

Auto-generated profile, based on publicly available information

Courtney Wilson


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 October 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
JTJadranka Travas-Sejdic
Jadranka Travas-Sejdic
CWCourtney Wilson
Courtney Wilson
LCLinda Yen-Chien Chen
Linda Yen-Chien Chen
YSYiling Sun
Yiling Sun
VNVolker Nock
Volker Nock
Meniscus-guided printing (MGP) has emerged as a versatile additive manufacturing strategy for the high-resolution fabrication of three-dimensional (3D) microarchitectures. However, the widespread implementation of soft, high-aspect-ratio conducting polymer (CP) microelectrodes for advanced bioelectronics remains limited by the lack of predictive frameworks linking printing parameters to print fidelity, mechanical stability, and electrochemical performance. We previously reported the direct MGP of high-aspect-ratio poly(3,4‑ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS) pillar microelectrode arrays with tunable structural and electrochemical properties. Herein, we build on these studies by systematically correlating fundamental printing parameters, including ink composition, rheological properties, printing dynamics, and post-print thermal annealing conditions, with the mechanical and electrochemical performance of the 3D PEDOT:PSS pillar microelectrodes. The 3D-printed pillar microelectrodes were fabricated with high aspect ratios (up to 17), excellent geometric uniformity, mechanical integrity, and reliable electrochemical properties. Electrochemical performance showed a strong dependence on microelectrode architecture, pillar height, and thermal processing conditions. Notably, the 50 µm-tall PEDOT:PSS pillar microelectrodes demonstrated an eightfold increase in electrochemically active surface area (ECSA) and a 46% reduction in interfacial impedance at 100 Hz compared with planar PEDOT:PSS microelectrodes. Further optimization of pillar height and thermal annealing at 180 °C for 10 min enabled the 200 µm-tall PEDOT:PSS pillar microelectrodes to achieve a 3.7-fold higher ECSA, three times larger double-layer capacitance, and 82% lower charge-transfer resistance than the 50 µm-tall PEDOT:PSS pillar microelectrodes. Overall, this work provides a customizable material-process-property optimization paradigm for the robust MGP of soft 3D PEDOT:PSS microelectrode arrays for next-generation bioelectronic interfaces, tissue engineering, and electrochemical biosensing technologies.