Adrien Hertault

Adrien Hertault

Auto-generated profile, based on publicly available information

Adrien Hertault

Vascular and Endovascular Surgery Department, Valenciennes General Hospital, Valenciennes, France

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2018 in European Journal of Vascular and Endovascular Surgery
Verified
Journal Article
Closed access
RSRafaelle Spear
Rafaelle Spear
JSJonathan Sobocinski
Jonathan Sobocinski
AHAdrien Hertault
Adrien Hertault
MDMatthieu Delloye
Matthieu Delloye
RARichard Azzauiu
Richard Azzauiu
SHStéphan Haulon
Stéphan Haulon

1 September 2020 in European Journal of Vascular and Endovascular Surgery
Verified
Journal Article
Closed access
AHAdrien Hertault
Adrien Hertault
ABAurélia Bianchini
Aurélia Bianchini
SASébastien Amiot
Sébastien Amiot
HCHovan Chenorhokian
Hovan Chenorhokian
FLFrancine Laurent-Daniel
Francine Laurent-Daniel
ALAnne Lejay
Anne Lejay

8 February 2021 in Journal of Endovascular Therapy
Verified
Journal Article
Closed access
PDF file
AHAdrien Hertault
Adrien Hertault
ABAurélia Bianchini
Aurélia Bianchini
GDGuillaume Daniel
Guillaume Daniel
TMTeresa Martin-Gonzalez
Teresa Martin-Gonzalez
BSBirgit Sweet
Birgit Sweet
SHStéphan Haulon
Stéphan Haulon
Purpose: To review a single-center experience with fenestrated and branched endovascular aneurysm repair (f/bEVAR) in patients with challenging iliac anatomies. Materials and Methods: A retrospective review of the department’s database identified 398 consecutive patients who underwent complex endovascular repair f/bEVAR between January 2010 and June 2018; of these, 67 had challenging accesses. The strategies implemented to overcome access issues were reviewed, using a dedicated scoring system to evaluate the access (integrating diameter, tortuosity, calcification, and previous open or endovascular repair). Results: In this subgroup of patients, the most common graft design was a 4-vessel fenestrated endograft (27, 40.3%). Hostile access was due to small diameter (<7 mm) in 25 patients (37.3%) and/or concentric calcifications in 19 patients (26.9%). Mean iliac diameter was 5.5±2.6 mm on the right side and 6.0±2.5 mm on the left side. Previous open or endovascular aortoiliac repair had been performed in 15 patients (22.4%), and 20 patients (29.9%) had a stent previously implanted in at least 1 iliac artery, resulting in the inability to perform standard fenestrated repair with access from both sides. Five patients (7.5%) had a single patent iliac access. Eight distinctive strategies were identified to overcome these access issues, including the use of preloaded renal catheters in the endograft delivery system, angioplasty, graft modification (branches instead of fenestrations or 4 preloaded fenestrations), a conduit via a retroperitoneal approach, iliac artery recanalization, and/or the multiple puncture technique. Technical success was achieved in 62 cases (92.5%). Four patients had access complications and 1 died in the early postoperative period of multiorgan failure. Median follow-up was 24.6 months (IQR 7.2, 41.3). Clinical success at the end of follow-up was achieved in 57 patients (85.1%). During follow-up, 14 patients died, including 4 from an aorta-related cause. Conclusion: Dedicated strategies can be implemented to overcome hostile iliac access in patients with complex aneurysms when f/bEVAR is required. Typically, these maneuvers are associated with favorable outcomes.

4 March 2021 in Journal of Endovascular Therapy
Verified
Journal Article
Closed access
PDF file
Giovanni TinelliGiovanni Tinelli
Giovanni Tinelli
MBMarie Bonnet
Marie Bonnet
AHAdrien Hertault
Adrien Hertault
SSSimona Sica
Simona Sica
GTGian Luca Di Tanna
Gian Luca Di Tanna
SHStéphan Haulon
Stéphan Haulon
Purpose: Evaluate the impact of hybrid operating room (HOR) guidance on the long-term clinical outcomes following fenestrated and branched endovascular repair (F-BEVAR) for complex aortic aneurysms. Materials and Methods: Prospectively collected registry data were retrospectively analyzed to compare the procedural, short- and long-term outcomes of consecutive F-BEVAR performed from January 2010 to December 2014 under standard mobile C-arm versus hybrid room guidance in a high-volume aortic center. Results: A total of 262 consecutive patients, including 133 patients treated with a mobile C-arm equipped operating room and 129 with a HOR guidance, were enrolled in this study. Patient radiation exposure and contrast media volume were significantly reduced in the HOR group. Short-term clinical outcomes were improved despite higher case complexity in the HOR group, with no statistical significance. At a median follow-up of 63.3 months (Q1 33.4, Q3 75.9) in the C-arm group, and 44.9 months (Q1 25.1, Q3 53.5, p=0.53) in the HOR group, there was no statistically significant difference in terms of target vessel occlusion and limb occlusion. When the endograft involved 3 or more fenestrations and/or branches (complex F-BEVAR), graft instability (36% vs 25%, p=0.035), reintervention on target vessels (20% vs 11%, p=0.019) and total reintervention rates (24% vs 15%, p=0.032) were significantly reduced in the HOR group. The multivariable Cox regression analysis did not show statistically significant differences for long-term death and aortic-related death between the 2 groups. Conclusion: Our study suggests that better long-term clinical outcomes could be observed when performing complex F-BEVAR in the latest generation HOR.

19 July 2020 in CardioVascular and Interventional Radiology
Verified
Journal Article
Closed access
PDF file
BDBart Doyen
Bart Doyen
BMBlandine Maurel
Blandine Maurel
AHAdrien Hertault
Adrien Hertault
PVPeter Vlerick
Peter Vlerick
TMTara M Mastracci
Tara M Mastracci
IHIsabelle Van Herzeele
Isabelle Van Herzeele

1 May 2019 in European Journal of Vascular and Endovascular Surgery
Verified
Journal Article
Closed access
AHAdrien Hertault
Adrien Hertault